SUNGROW 36kW 3 Phase String Inverter Installation Guide

June 13, 2024
SUNGROW

SunGrow-logo

SUNGROW 36kW 3 Phase String Inverter

SUNGROW-36kW-3-Phase-String-Inverter-product

Product Information: 3-phase String Inverter

The 3-phase string inverter is a device designed for converting DC (direct current) power generated by solar panels into AC (alternating current) power that can be used for various electrical applications. This inverter is suitable for use in 3-phase solar power systems.

Installation Requirements
Location Requirements: It is important to select an optimal mounting location for the inverter to ensure safe operation, long service life, and expected performance.

Carrier Requirements: The concrete wall used for installation should be able to withstand a force of four times the weight of the inverter. It should also be suitable for the dimensions of the inverter. The installation carrier must meet the following requirements:

  • Angle Requirements: The inverter should be installed vertically. It should never be installed horizontally, tilted forward/backward, tilted to the side, or upside down.
  • Clearance Requirements: Adequate clearance should be reserved around the inverter to ensure sufficient space for heat dissipation. If multiple inverters are being installed, specific clearance should be reserved between them.

Please refer to the user manual for further information on installation requirements and guidelines. The manual is intended  for professional technicians who are responsible for the installation, operation, maintenance, and troubleshooting of  inverters. Only professional technicians should install the inverter.
To download the user manual, click here.

Product Usage Instructions

Follow these instructions to properly use the 3-phase string inverter:

  1. Ensure that the inverter is installed in a suitable location according to the installation requirements mentioned above.
  2. Make sure the concrete wall used as the installation carrier meets the specified strength requirements.
  3. Install the inverter vertically, ensuring it is not installed horizontally, tilted in any direction, or upside down.
  4. Provide adequate clearance around the inverter to allow for proper heat dissipation.
  5. If installing multiple inverters, ensure there is specific clearance between them.
  6. Refer to the user manual for detailed instructions on connecting the inverter to the solar panels and electrical system.
  7. Consult the user manual for information on configuring and adjusting inverter parameters.
  8. Regularly inspect and maintain the inverter according to the guidelines provided in the user manual.

For any technical issues or troubleshooting, contact a professional technician who is familiar with the product and its operation.

Installation requirements

Applicable to: 3-phase string inverters

Location Requirements:
Select an optimal mounting location for safe operation, long service life and expected performance.

  • The inverter with protection rating IP65 can be installed both indoors and outdoors.
  • Install the inverter in a convenient place for electrical connection, operation and maintenance

Environment Requirements:

  • The installation environment must be free of inflammable or explosive materials.
  • The location should be not accessible to children.
  • The ambient temperature and relative humidity must meet the following requirements.
  • Avoid direct exposure to sun, rain and snow.
  • The inverter should be well ventilated. Ensure air circulation.
  • Never install the inverter in living areas. The inverter will generate noise during operation, affecting daily life.

SUNGROW-36kW-3-Phase-String-Inverter- \(2\)

Carrier Requirements
The concrete wall should be capable of withstanding a force of four times the weight of the inverter and be suitable for the dimensions of the inverter. The installation carrier should meet the following requirements:

Angle Requirements
Install the inverter vertically. Never install the inverter horizontally, or at forward/ backward tilted, side tilted, or upside down.

SUNGROW-36kW-3-Phase-String-Inverter- \(4\)

Clearance Requirements
Reserve enough clearance around the inverter to ensure sufficient space for heat dissipation.

In case of multiple inverters, reserve specific clearance between the inverters.

SUNGROW-36kW-3-Phase-String-Inverter- \(6\)

For further information, please download the user manual here.
This manual is intended for professional technicians who are responsible for installation, operation, maintenance and troubleshooting of inverters, and users who need to check inverter parameters. The inverter must only be installed by professional technicians.
The professional technician is required to meet the following requirements:

  • Know electronic, electrical wiring and mechanical expertise, and be familiar with electrical and mechanical schematics.
  • Have received professional training related to the installation, commissioning and troubleshooting of electrical equipment.
  • Be able to quickly respond to hazards or emergencies that occur during installation, commissioning and troubleshooting.
  • Be familiar with local standards and relevant safety regulations of electrical systems.
  • Read this manual thoroughly and understand the safety instructions related to operations.

© 2021 Sungrow. All rights reserved. Subject to change without notice. Version 1.1

Sungrow Deutschland GmbH | Balanstr. 59 | 81541 München | www.sungrowpower.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals