Qolsys QS-IQSKM Encrypted Door Window Sensor Installation Guide
- June 13, 2024
- Qolsys
Table of Contents
IQ SHOCK MINI-S QUICK INSTALL GUIDE
QS-IQSKM Encrypted Door Window Sensor
STEP 1 CHOOSE INSTALLATION LOCATION
SPECIFICATIONS
Sensor: 2.5”H x 1”W x .5”D
Code outputs: tamper, tamper restore, alarm, alarm restore, low battery.
Transmitter frequency: 319.5 MHz
Supervisory keep-alive interval: 70 minutes.
RF Peak field strength: typical 36000 uV/m at 3m UL/ULC listed for residential
use only
Operating Temperature: -5C~45C
Relative Humidity: 5-95% Non-Condensing
Storage Temperature: -25-70C
Replace battery with exact replacement every 5 years with 3V CR2032 Lithium
(x2).
STEP 2 DIP SWITCH CONFIGURATION
Two dip switches allow you to customize the behavior of this device:
DS#1 – Installer Test Mode:
ON:- Calibrates accelerometer orientation.
– LED is Active for dialing in shock sensitivity with potentiometer.
– Please note, when test mode is enabled (ON) the IQ Shock Mini will NOT
transmit signals to the IQ Panel. This mode is only used for initial
installation and calibration of the shock sensor.
OFF: – Disables installer test mode.
DS#2 – Reed Switch:
ON: – Enables reed switch (must be ON for UL installations).
OFF: – Disables reed switch.
Sensitivity Level:
CLOCKWISE: – More Sensitive
COUNTERCLOCKWISE: – Less Sensitive
IMPORTANT NOTE: The IQ Shock is intended to be installed on doors with or without glass inserts and on window frames but not on the actual glass surface.
STEP 3 REMOVE BATTERY
STEP 4 APPLY ADHESIVE
STEP 5 MOUNT SENSOR & MAGNET
STEP 6 LEARN INTO PANEL
| |
---|---|---
Place your panel in “Auto Learn” mode| Open and close the case to “tamper” the
device| Customize name and settings as desired and and touch “ADD”
STEP 7 ADJUST SHOCK SENSITIVITY
Adjusting the Shock Sensitivity:
IMPORTANT: Calibrate the IQ Shock Mini’s accelerometer from the final
mounting position by moving dip switch 1 to ON (enable installer test mode).
While in this mode the LED will flash GREEN when the unit detects a pre-warn
threshold. The LED will flash RED when it detects a shock level strong enough
to trigger an alarm at the control panel. There are 5 total sensitivity
settings and the LED will flash each time the sensitivity threshold is
changed. Please note that no RF transmission from the sensor occurs during
installer test mode.
Gently hit (using the palm of your hand) the surface on which the device is
installed. Gradually increase the pressure or turn the shock sensitivity
adjustment dial clockwise with a small screwdriver until the desired response
is obtained. Ensure that the device is not triggered by accidental vibration
(e.g., wind, birds, window coverings) hitting the protected window or
surface. Normal traffic or operation of the door/window should not trip the
shock sensor. When testing the sensitivity of the unit, do not cause stress or
damage to the mounting surface or to the glass. WARNING: In order to
avoid personal injury while testing sensitivity, do not apply pressure to
glass inserts or windows.
Move dip switch 1 to OFF (disable installer test mode) once shock sensitivity
has been set to the desired level. Verify that the IQ Shock Mini properly
communicates with the Panel.
Document#: IQSM-QG
Revision#: 02/14/23
Qolsys Product #: IQSM
FCC ID: 2AAJXQS-IQSKM
IC: 11205A-QSIQSKM
UL/ULC NOTE:
The IQ Shock Mini – S has been listed by UL/ULC for residential applications
only and in accordance with the requirements in the Standards UL 634 and
UKLC/ORD-C634 for Door and Window Contact with supplementary Shock Sensor.
The shock sensor is for supplementary detection only and not for primary
protection of the surface and is not intended for use as a glass break
detector.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
This is a quick guide for experienced installers only. Refer to http://dealers.qolsys.com (login required)