Quickstart

This is a
secure
Multilevel Switch
for
.

To run this device please connect it to your mains power supply.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

The IQ Smart Dimmer can be used to turn any outlet into a smart outlet to turn lamps On, Off, or control dimming of any lamps with dimmable light bulbs. Each Z-Wavedevice also serves as a repeater in the Z-Wave network, extending and improving the mesh network in the installed location.The IQ Smart Dimmer is a Z-Wave Pluscertified device and includes S2 security and SmartStart. You can now add this device securely and with ease using QR code on the box or device.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country- specific
installation guidelines/norms may do works with mains power. Prior to the assembly of
the product, the voltage network has to be switched off and ensured against re-switching.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1| 1| Lifeline. QZ2142-840 will trigger AUTO report function if the Switch status had been changed.
---|---|---
2| 5| When the output of the QZ2142-840 is changed, On (0xFF) or Off (0x00). The QZ2142-840 will automatically send out a related basic set command On (0xFF) or Off (0x00) to its associated group.
3| 5| When the output of the QZ2142-840 is changed, On (0xFF) or Off (0x00). The QZ2142-840 will automatically send out a related basic set command On (0xFF) or Off (0x00) to its associated group.

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 10: Multilevel minimumvalue can be set

Multilevel minimumvalue can be setLocal Button > this should apply to both for local or Z-Wave operationParameter=10Size=1Value=0disableValue=1..Value=99 Default = 1
Size: 1 Byte, Default Value: 1

SettingDescription

0 Disabled
1 – 99 Minimum multilevel level

Parameter 11: Multilevel maximumvalue can be set

Multilevel maximumvalue can be setLocal Button > this should apply to both for local or Z-Wave operationParameter=11Size=1Value=0disableValue=1..Value=100- NOT ACCEPTED BY HUBDefault = 99
Size: 1 Byte, Default Value: 99

SettingDescription

0 Disabled
1 – 100 Maximum multilevel level

Parameter 12: Double Tap Behavior

Double Tap Behavior: when switch is off and quickly press UPPER paddle 2 times, switch turns on to x brightnessLocal Button Parameter=12Size=1Value = 0enable double tap to full brightness (99)Value = 1 custom value set in parameter 18 Value = 2 enable double tap to maximum brightness (turn on to the value relate with parameter 11) Value = 3 disable double tap to full brightnessDefault = 0
Size: 1 Byte, Default Value: 0

SettingDescription

0 Double tap goes to full brightness
1 Double tap goes to custom value in Parameter 18
2 Double tap goes to maximum brightness based on Parameter 11
3 Disable double tap to full brightness

Parameter 15: Enable or Disable local / Z-Wave control

Enable or Disable local / Z-Wave control Parameter=15Size=1Value=0 disable (when paddle pressed switch will not turn light on or off BUT it will still control the light via z-wave and it will change LED indicator status and on/off/multilevel status when paddle is pressed)Value=1 enable (normal operation like now)Value = 2 disable local and Z-Wave control (LED and on/off status will still change if paddle pressed) >> make sure that status is still reported and LED indicator changes when Z-Wave control is disabledDefault = 1
Size: 1 Byte, Default Value: 1

SettingDescription

0 Disable local control
1 Enable local Z-Wave control
2 Disable local and Z-Wave Control

Parameter 16: dimmer speed

dimmer speed (only for local press & hold): amount of seconds it takes to go from 0 to 100% brightness when pressing and holding the paddleParameter=16Size=1,Value=1from 0x63 to 0x00 or from 0x00 to 0x63 need 1sValue=2 from 0x63 to 0x00 or from 0x00 to 0x63 need 2s ..Value=99 from 0x63 to 0x00 or from 0x00 to 0x63 need 99sDefault = 5
Size: 1 Byte, Default Value: 5

SettingDescription

1 – 99 Dimming speed in seconds

Parameter 18: Custom brightness level

Custom brightness level – in this parameter define default brightness level the switch will turn on to from main switch or regular switch in 3-way when pressed upper paddle once.Parameter: 18Size: 1 byte decValues 0-990 – last brightness level1-99 custom brightness leveldefault = 0
Size: 1 Byte, Default Value: 0

SettingDescription

0 Last brightness level
1 – 99 Custom brightness level

Parameter 19: 3-way switch type

3-way switch typeParameter=19,Size=1,Value=0 toggle switch(device changes status when switch changes status,it can only turn on or turn off lamp,it cant dimmer)(default);Value = 1toggle switch(press 1x change device status;quickly press 2x the result dependonPar11/Par12; quickly Press 3x it trigger dimmer in loop(dimmer up/dimmer down )Value=2 momentary switch (press 1x change device status;quickly press 2x the result dependonPar11/Par12;holdtrigger dimmer in loop(dimmer up/dimmer down )Value=3 momentary switch (press 1x change device status;quickly press 2x the result dependonPar11/Par12;holdtrigger dimmer in loop(dimmer up/dimmer downBUT after double click to full brightness, hold will dim DOWN always instead of trying to increase brightness) >> This value is missing, please add to settingNotice: when the value=1,or value=2,the switch cant respond immediately,because it need to recognize multiplepress.
Size: 1 Byte, Default Value: 0

SettingDescription

0| toggle switch(device changes status when switch changes status, it can only turn on or turn off lamp
---|---
1| toggle switch(press 1x change device status; quickly press 2x the result dependonParameter 11 and 12
2| momentary switch (press 1x change device status; quickly press 2x the result dependonPar11 and 12
3| momentary switch (press 1x change device status; quickly press 2x the result dependonPar11 and Par12

Parameter 2: LED Indicator

Parameter=2Size=1Value=0 On when Off and Off when OnValue=1On when On and Off when OffValue=2Always OffValue=3Always OnDefault =0
Size: 1 Byte, Default Value: 0

SettingDescription

0 Output and the LED are in the different state.
1 Output and the LED are in the same state.
2 LEDAlways OFF
3 LEDAlways ON

Parameter 20: Association reports

Association reportsParameter=20,Size=1Values:0Z-WavecontrolMultilevelreport (withouteachlevel,justfinallevel)Manualcontrol (shortpress):Basicreport(withouteachlevel,justfinallevel)Manualcontrol(longpress & relayenable):Basicreport(withouteachlevel,justfinallevel)Manualcontrol(longpress &relaydisable):Multilevelreport (eachlevelwillbereported) 1Z- WavecontrolMultilevelreport (withouteachlevel,justfinallevel)Manualcontrol (shortpress):Basicreport (withouteachlevel,justfinallevel)Manualcontrol(longpress & relayenable OR disable):Basicreport (withouteachlevel,justfinallevel)2Z- WavecontrolMultilevelreport (withouteachlevel, justfinallevel)Manualcontrol (shortpress): Multilevel report (withouteachlevel, justfinallevel)Manualcontrol (longpress & relayenable):Multilevelreport (withouteachlevel, justfinallevel)Manualcontrol (longpress &relaydisable):Multilevelreport (eachlevelwillbereported)default = 2
Size: 1 Byte, Default Value: 2

SettingDescription

0| Z-WavecontrolMultilevelreport (withouteachlevel,justfinallevel) Manualcontrol (shortpress):Basicreport(withouteachlevel,justfinallevel) Manualcontrol(longpress & relayenable):Basicreport(withouteachlevel,justfinallevel) Manualcontrol(longpress &relaydisable):Multilevelreport (eachlevelwillbereported)
---|---
1| Z-WavecontrolMultilevelreport (withouteachlevel,justfinallevel) Manualcontrol (shortpress):Basicreport (withouteachlevel,justfinallevel) Manualcontrol(longpress & relayenable OR disable):Basicreport (withouteachlevel,justfinallevel)
2| Z-WavecontrolMultilevelreport (withouteachlevel, justfinallevel) Manualcontrol (shortpress): Multilevel report (withouteachlevel, justfinallevel) Manualcontrol (longpress & relayenable):Multilevelreport (withouteachlevel, justfinallevel) Manualcontrol (longpress &relaydisable):Multilevelreport (eachlevelwillbereported)

Parameter 21: Disabled Relay Behavior

Disabled Relay BehaviorParameter=21,Size=1Value=0 report on/off and multilevelstatus when paddle is pressed and change LED indicatorstatus and Parameter 15 is set to value 0 or 2 (output control disabled) according to setting in Parameter 20.Value=1 DONt report on/off or multilevel status or and change LED indicator status when paddle is pressed and Parameter 15 is set to value 0 or 2 (output control disabled). Default = 0
Size: 1 Byte, Default Value: 0

SettingDescription

0| report on/off and multilevelstatus when paddle is pressed and change LED indicatorstatus and Parameter 15 is set to value 0 or 2 (output control disabled) according to setting in Parameter 20.
---|---
1| DONt report on/off or multilevel status or and change LED indicator status when paddle is pressed and Parameter 15 is set to value 0 or 2 (output control disabled).

Parameter 22: Night Mode Brightness Level

Night Mode Brightness LevelSet the level of brightness the dimmer will turn on to when off and lower paddle held DOWN for 2 seconds.Parameter=22,Size=1Values: 0- disable function; 1-99 %Default:: 20
Size: 1 Byte, Default Value: 20

SettingDescription

0 Disabled
1 – 99 Brightness level

Parameter 23: LED Indicator Color

LED Indicator ColorParameter=23Size=1Value=0 WhiteValue=1BlueValue=2GreenValue=3RedDefault = 1
Size: 1 Byte, Default Value: 1

SettingDescription

0 White
1 Blue
2 Green
3 Red

Parameter 24: LED Indicator Brightness

LED Indicator BrightnessParameter=24Size=1Value=0 Bright (100%)Value=1Medium (60%)Value=2Low (30%)Default =1
Size: 1 Byte, Default Value: 1

SettingDescription

1 Medium (60%)
2 Low (30%)
0 Bright (100%)

Parameter 25: Single Tap Behavior

Single Tap Behavior: when switch is off and press UPPER paddle 1 time, switch turns on to x brightnessLocal Button Parameter=25Size=1Value = 0last brightness level Value = 1 custom value set in parameter 18 Value = 2 maximum brightness set in parameter 11 Value = 3 full 100% brightnessDefault = 0
Size: 1 Byte, Default Value: 0

SettingDescription

0 last brightness level
1 custom value set in parameter 18
2 maximum brightness set in parameter 11
3 full 100% brightness

Parameter 3: Auto Turn-Off Timer

Auto Turn-Off Timer— Values: 065535 (minutes)
Size: 4 Byte, Default Value: 0

SettingDescription

0 Default
1 – 65535 165535 (minutes)

Parameter 5: Auto Turn-On Timer

Auto Turn-On Timer
Size: 4 Byte, Default Value: 0

SettingDescription

0 Default
1 – 65535 165535 (minutes)

Parameter 8: Restores state after power failure

Restores state after power failureParameter=8Size=1Value=0 output offValue=1 output onValue=2out put the state after powerDefault =2
Size: 1 Byte, Default Value: 2

SettingDescription

0 Output OFF
1 Output ON
2 The state before a power outage

Parameter 9: Ramp rate

Ramp rateLocal Button + Z-Wave > change to local and Z-Wave like in the latest ZEN30 firmware, also applies to any multilevel changes (so there should be soft transition between 20 and 80% brightness if changed from the hub for example)Parameter=9Size=1,Value=1from 0x63 to 0x00 or from 0x00 to 0x63 need 1sValue=2 from 0x63 to 0x00 or from 0x00 to 0x63 need 2s ..Value=99 from 0x63 to 0x00 or from 0x00 to 0x63 need 99sDefault = 1
Size: 1 Byte, Default Value: 1

SettingDescription

1 – 99 Ramp rate in seconds

Technical Data

Hardware Platform ZGM130
Device Type Multilevel Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.00
Z-Wave Version 7.13.6
Certification ID ZC12-22040337
Z-Wave Product Id 0x012A.0xFF00.0xFF0D
Security V2 S2_UNAUTHENTICATED ,S2_AUTHENTICATED
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Association Grp Info V3
  • Association V3
  • Basic V2
  • Central Scene V3
  • Configuration V4
  • Device Reset Locally
  • Firmware Update Md V5
  • Indicator V3
  • Manufacturer Specific V2
  • Multi Channel Association V3
  • Switch Multilevel V4
  • Powerlevel
  • Security 2
  • Supervision
  • Transport Service V2
  • Version V3
  • Zwaveplus Info V2

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.