Ecodesign Regulation (EU) 2015/1188 concerning local space heaters does not apply to all application areas.
The Regulation applies when an installation is intended to provide thermal comfort for people in the premises. The Regulation does not apply to heating installations of a more technical nature e.g. in engineering/utility rooms, in production processes, frost protection, etc. The Regulation also does not apply to installations in vehicles, offshore or outdoors.
Many of Frico’s products can be used as both local space heaters (as defined in (EU) 2015/1188) and for technical heating purposes. It is up to the installer responsible for the installation to assess whether the Ecodesign Regulation is applicable or not. Control solutions for installations not covered by the Ecodesign Regulation are listed in a separate table.

FRICO EZ300 Heavy Duty Panel Heaters - FIGURE 1

| L [mm]| A [mm]| B [mm]
---|---|---|---
EZ336| 1670| 1200| 235
EZ345| 2030| 1500| 265

FRICO EZ300 Heavy Duty Panel Heaters - Mounting Wires (not supplied)
CeilingFRICO EZ300 Heavy Duty Panel Heaters -
PositioningFRICO EZ300 Heavy Duty Panel
Heaters - Minimum distances

| EZ300 [mm]
---|---
A| 120
B| 250
C| 250
D| 700
E| 1800

Controls

Item number Type HxWxD [mm]
92790 TAP16R 87x87x53
205540 TEP44 87x87x55
93012 RB3 155x87x43
205688 RB123 155x87x43
93044 RTX54 82x88x25
205550 SKG30 115x85x40
211780 PDK65 102x70x50

FRICO EZ300 Heavy Duty Panel Heaters - Controls

Controls for installations not covered by the Ecodesign Regulation (EU) 2015/1188

Item number Type HxWxD [mm]
5999 KRT1900 165x57x60
10214 KRTV19 165x57x60
11733 S123 72x64x46

FRICO EZ300 Heavy Duty Panel Heaters - Controls 2

Elztrip EZ300 (IP44)

Item number| Type| Heat output [W]| Voltage [V]| Amperage [A]| Max. surface temperature [°C]| Dimensions LxHxW
[mm]| Weight [kg]
---|---|---|---|---|---|---|---
11070| EZ336| 3600| 230V3~/400V3N~| 9,0/5,2| 320| 1670x63x420| 19,8
11071| EZ345| 4500| 230V3~/400V3N~| 11,3/6,5| 320| 2030x63x420| 24,2

  • Heat output
  • Voltage
  • Amperage
  • Max. surface temperature
  • Weight

Wiring diagrams

FRICO EZ300 Heavy Duty Panel Heaters - Wiring diagrams

Control with thermostat and relaybox

FRICO EZ300 Heavy Duty Panel Heaters - relaybox

Control by thermostat, relaybox and black bulb sensor

FRICO EZ300 Heavy Duty Panel Heaters - bulb sensor

Control by relaybox with 3 step output control and presence detector

FRICO EZ300 Heavy Duty Panel Heaters - presence
detector

Control with thermostat, contactor and switch – for installations not covered by the Ecodesign Regulation (EU) 2015/1188

FRICO EZ300 Heavy Duty Panel Heaters - Ecodesign
Regulation

Main office
Frico AB
Tel: +46 31 336 86 00
Industrivägen 41
SE-433 61 Sävedalen
Sweden
mailbox@frico.se
www.frico.net
For latest updated information and information
about your local contact:www.frico.net
Art.no: 206472 2022-12-14 HH/CH

Documents / Resources

| FRICO EZ300 Heavy Duty Panel Heaters [pdf] Instruction Manual
EZ300, EZ300 Heavy Duty Panel Heaters, Heavy Duty Panel Heaters, Duty Panel Heaters, Panel Heaters, Heaters
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals