tecnare DMA 8X8 Dsp Matrix User Manual

June 13, 2024
tecnare

Operation Manual

tecnare DMA 8X8 Dsp Matrix -

Commercial Series
DMA 8X8
DSP MATRIX

Keep these important operatin instructions.
Check www.tecnare.com for updates

IMPORTANT SAFE INSTRUCTIONS

Before using our product, be sure to carefully read the manual and safe Instructions. Keep this document with the device all time.

  1. Read these instructions

  2.  Keep these instructions.

  3.  Heed all warnings.

  4.  Follow all SAFETY INSTRUCTIONS as well DANGER and OBLIGATION warnings.

  5. Only use attachments / accessories specified by Exel Acoustics SL.

  6. Do not use this apparatus near water.

  7. Clean only with dry cloth.

  8. Do not block any ventilation openings. Install in accordance with Exel Acoustics’ instructions.

  9. Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus (including amplifiers) that produce heat.

  10. Do not defeat the safety purpose of the polarized or grounding type plug. A polarized plug has two blades with one more wide than the other. A grounding type plug has two blades and a third pin are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

  11.  Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles and the point where they exit from the apparatus.

  12. Unplug this apparatus during lightning storms or when unused for long periods of time.

  13. Refer all servicing to qualified service personnel. Service is required when the apparatus has been damaged in any way, such as power-supply cord or plug damaged, liquid has been spilled or objects have fallen into the apparatus, this apparatus has been  x-posed to rain or moisture, does not operate normally, or has been dropped.
    CAUTION: To reduce the risk of fire of electric shock, do not expose this device to rain or moisture.

  14.  Use the mains plug to disconnect the device from mains.

  15. Do not expose this equipment to dripping or splashing and ensure that no objects filled with liquids, such as vases, are placed on the equipment.

  16. The mains plug of the power supply cord shall remain readily operable.

  17.  Do not connect the unit’s output to any other voltage source, such as battery, mains source, or power supply, regardless of whether the unit is turned on or off.

  18. Do not remove the top (or bottom) cover. Removal of the cover will expose hazardous voltages. There are no user serviceable parts inside and removal may void warranty.
    CAUTION: Do not remove any covers, loosen any fixings or allow items to enter any aperture
    CAUTION: The rear of the product may get hot. Avoid direct skin contact during operation and for at least 5 minutes after power has been isolated.
    CAUTION: The product must only be positioned at floor level when operated in a horizontal position.

  19.  If the equipment is used in a manner not specified by the Exel Acoustics, the protection by the equipment may be impaired.

SYMBOL USED

Warning
This simbol indicate Risk of injury. It is essential to observe this warning. Non-compliance can lead to serious injury or death.
Caution
This simbol indicate Personal injuries. It is essential to observe this warning. Non-compliance can lead to minor or slight injury.
Notice
This simbol indicate Damage to the devices or environment. It is essential to observe this warning. Non-compliance can lead to damage to property or equipment or environmental damage.
tip or pointer
This simbol indicate information that contributes to better understanding.

STANDARDS

FOR CUSTOMERS IN EUROPE
This product complies with both the LVD (electrical safety) 73/23/EEC and EMC (electromagnetic compatibility) 89/336/EEC directives issues by the commission of the European community.
Compliance with these directives implies conformity with the following European standards:
EN60065 Product safety
EN55103-1 EMC emissions
EN55103-2 EMC immunity

This product is intended for the following electromagnetic environments: E1, E2; E3 & E4.
THIS PRODUCT MUST BE EARTHED. Use only a flexible cable or cord with a green and yellow core which must be connected to the protective earthing terminal of a suitable mains plug or the earthing terminal of the installation. The cord must be a maximum of 2m long, have a 2.5mm2 CSA, a 300/500V rating and comply with EN50525-2-11 / H05W-F.
THIS PRODUCT IS DESIGNED FOR PERMANENT INSTALLATION. It must be fitted in to a 19” rack enclosure and not operated unless so installed. The rack enclosure should be open at the front and back to allow free ventilation and movement of air through the product.
FOR CUSTOMERS IN THE USA
This product has been tested for electrical safety and complies with UL60065 7th edition THIS PRODUCT MUST BE EARTHED. Use only a flexible cable or cord with a green or green / yellow core which must be connected to the protective earthing terminal of a suitable mains plug or the earthing terminal of the installation. The cord must be a maximum of 6’ long, be 14AWG, have a rating SJ,  SJT, SJE or 300/500VH05W-F and be marked VW-1.
THIS PRODUCT IS DESIGNED FOR PERMANENT INSTALLATION. It must be fitted in to a 19” rack enclosure and not operated unless so installed. The rack enclosure should be open at the front and back to allow free ventilation and movement of air through  the product.
DECLARATION OF CONFORMITY WITH FCC RULES
We, EXEL Acoustics SL, CL Encinar 282, Pol. Ind. Monte Boya, 45950 – Casarrubios del Monte (Toledo), España, declare under our sole responsibility that this family of devices, complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FEDERAL COMMUNICATIONS COMMISSION NOTICE An example of this equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential and commercial installation.
This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the distance between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
FOR CUSTOMERS IN THE CANADA
This product complies with CA /CSA C22.2 No.60065-03
Ce produit est conforme avec CA /CSA C22.2 No.60065-03
THIS PRODUCT MUST BE EARTHED. Use only a flexible cable or cord with a green or green / yellow core which must be connected to the protective earthing terminal of a suitable mains plug or the earthing terminal of the installation. The cord must be a maximum of 6’ long, be 14AWG, have a rating SJ, SJT, SJE or 300/500V H05W-F and be  marked VW-1.
THIS PRODUCT IS DESIGNED FOR PERMANENT INSTALLATION. It must be fitted in to a 19” rack enclosure and not operated unless so installed. The rack enclosure should be open at the front and back to allow free ventilation and movement of air through the product.
DECLARATION OF CONFORMITY WITH CANADIAN ICES-003
This Class B digital apparatus complies with Canadian ICES-003.

DECLARATION OF CONFORMITY

**** EXEL ACOUSTICS SL
Declare under our sole responsibility that the DMA 8×8 amplifier products comply with relating Directives:

  1. Low Voltage Directive 2014/35/EU
  2. EMC 2014/130/EU
  3.  RoHS Directive 2011/65/EU
  4. WEEE Directive 2012/19/EU

In compliance with these Harmonized European Norms:

  1. EN60065 8th. Audio, video and similar electronic apparatus. Safety requirements.
  2. EN55032:2012. EMC emissions & immunity.
  3.  EN55035-2017

Welcome and unpacking

1.1. Welcome to Tecnare
Thank you for choosing a Tecnare® DMA 8X8 fully programmable digital audio matrix for your apli- cation.
Please spare a little time to study the contents of this manual, so that you obtain the best possible performance from this unit.
All Tecnare® products are carefully engineered for world-class performance and reliability.
If you would like further information about this or any other Tecnare® product, please contact us. We look forward to helping you in the near future.
As part of a continuous evolution of techniques and standards, Exel Acoustics SL as manufacturer of Tecnare ® products reserve the right to change the specifications of its products and the content of its docu- ments without prior notice.
Updates and supplementary information are available on the Tecnare® website:
http://www.tecnare.com
Tecnare Technical Support is available at:

Thank you again for placing your confidence in Tecnare® products.

1.2. Unpacking
After unpacking the unit please check carefully for damage. Every Tecnare product is tested and inspected before leaving the factory and should arrive in perfect condition. If damage is found, please notify the carrier concerned at once. You, the consignee, must instigate any claim. Please retain all packaging in case of future re-shipment.
1.3. The User Guide
This user manual gives a progressively more detailed description of the functions of the Tecnare DMA 8X8 Matix processor.
A detailed explanation describes each individual function or feature with annotated images explaining its use is contained in the next sections. Where appropriate, the graphical display is shown to further elaborate on the unit operation.
To complete the manual a reference section is included, describing the technical performance and Mechanical drawing of the device.

Overview

2.1. Introduction
The DMA 8X8 is equipped with several core technical features to facilitate the work of audio engineers. DSP-based remote audio equipment is routed, processed and controlled by computer. The Tecnare DSP Controller is a Windows-based application, which is used to conduct configuration and control of DSP hardware. DSP Controller has 16 built-in presets, and the modules and sequences for each preset can be flexibly designed in accordance with the designer’s requirements. After the design is finished, it can be saved for future use. The sequences and parameters of DSP Controller’s built-in processing modules accord to most of the application scenarios without any change. DSP Controller is a full-featured application, including the parameter adjustment and peripheral acces- sory settings of all modules, such as RS232, RS485, click-and-drag panel configuration and optional Dante network audio control. The most interesting part is the user interface, which allows the engineer to customize user interface so that the Integrator can edit it or the on-site technicians or end users who have no idea of relevant techniques can operate it. Superior safety functions make it possible for the end users to access to the controls allowed by the engineer or designer.

2.2. Key features

  • DANTE® network audio optional

  • Network TCP / IP control, can realize management of multiple devices

  • 8 balanced MIC/LINE inputs (independent phantom power per input channel)

  • 8 balanced LINE outputs

  • Built-in ADI SHARC DSP 21489

  • 4 GPIO control ports (General Purpose Input / Output)

  • Programming and remote management via Ethernet Using Tecnare DSP Controller (also point-to-point, with a direct CAT5 cable, or from an Ethernet network)

  • Remote control bus for DMA digital Panel

  • 16 Configuration memory presets

  • Extensive DSP available:
    ◦ Routing matrix/mixer, from any input to any output with adjustable level, crossover points (in- dependent mixes of different inputs for each output)
    ◦ Link channel processing
    ◦ Level control, muter, meters, polarity and input sensitivity selector for inputs and outputs
    ◦ Internal signal generator ( sine, white and pink noise) for input
    ◦ Parametric EQ on inputs and outputs
    ◦ Expander, compressor, Auto Gain Control and Feedback Inhibition for each input channel
    ◦ Delay and limiter setting for each output channel
    ◦ Automixer

  • USB Soundcard

2.3. Front and Rear Panel
2.3.1. The Front Panel and LED indicators
The DMA 8X8 system is designed to be mounted in a standard 19”/1HU rack enclosure.

tecnare DMA 8X8 Dsp Matrix - fig1

On the front panel, an LED (PWR) lights up when the unit is switched on. A second LED (STATUS) indicates the operation status of the device.

  • Status LED indicator (STATUS):
    ◦ If the device is switched on and the device is configured, the LED continuously toggles between green and unlit even if it is not connected to Ethernet.
    ◦ If the device is switched on and it has been “reset to default” or “Restore to Factory Setting”, the LED would be on permanently.

2.3.2. The Rear Panel
The rear panel of the DMA 8X8 offers 8 balanced analogue signal inputs accepting both line and  mic level signals, 8 analogue signal output, an RJ45 type connector, a GPIO for 0-5 Vdc continuous control voltage,RS-232 & RS485 port, USB audio port and Power connector.

tecnare DMA 8X8 Dsp Matrix - fig2

  • Main socket: 230 Vac / 50Hz; 40W
  • Ethernet Connector (RJ45): 10/100 Base-T Ethernet connector is used for IP-based PC Software and host and third-party accessory controller.
  • GPIO: 6-bit 3.81mm terminal. 4 input/output contacts to be assigned to different functions.
  • RS-485: Used as serial communication port A-B that’s connects to a third-party control device. The Port setting should comply with the following specifications: 115200 baud (default), 8 data bits, 1 stop bit, no parity, no flow control.
  • RS-232: Used for the serial communication port Tx = sending or data output or Rx = receiving or data input that connects to a third-party control device. The Serial Port setting should comply with the following specifications: 115200 baud (default), 8 data bits, 1 stop bit, no parity, no flow control.
  • USB Audio Port: USB soundcard (1-in-1-out), which can be used to play audio or for recording function.
  • Signal Input & Output terminal: Signal input and output connectors are 3 position screw terminal block.

Connections

3.1. Audio Input Connections
The rear panel of DMA 8X8 offer 8 balanced analogue MIC/LINE inputs. It features a couple of removable balanced 12 pin Phoenix terminal strips.

tecnare DMA 8X8 Dsp Matrix - fig3

Analog input section supports microphone or line-level signals whit nominal levels of 0dBu, 10dBu, 20dBu, 30dBu, 40dBu and 43dBu. +48VDC phantom power can be adopted for each input. Preamp gain and phan-

tecnare DMA 8X8 Dsp Matrix - fig4

tom power can be easily controlled through the Tecnare DSP Controller.
Fig. 5 Input source setting on the Tecnare DSP Controller Software

3.2. Audio Output Connections
The rear panel of DMA 8X8 offer 8 balanced analogue MIC/LINE inputs. It features a couple of removable balanced 12 pin Phoenix terminal strips .
Unit gain (0dB) is set through volume control, and the analogue output section is corrected to +4dBu with 20dB headroom. That is to say, 0dBFS digital signal is equivalent to +24dBu output signal. If other signal levels are required, you may change the volume to achieve it.

3.3. Audio Wiring Reference

  •  Balanced Connection

The HOT, + or ‘in phase’ connection should be made to pin + on the terminal strips or pin 2 of the XLR connector.
The COLD, – or ‘out of phase’ connection should be made to pin – on the terminal strips or pin 3 of the XLR connector.
GND Pin, corresponding with Pin 1 of the XLR connectors is internally connected to the chassis.
The shield of the input cable should always be connected Pin 1 to ensure the EMC performance and

tecnare DMA 8X8 Dsp Matrix - fig6

Note: For one XLR interface, the female connects to the output device and the male connects to the input device.

  •  Using unbalanced connection

Please note that the use of unbalanced connections is not recommended, however when connecting the matrix to an unbalanced audio source, the signal conductor should be connected to XLR pin2. The ‘Cold’ conductor or cable screen should be connected to pin 1 with a short connection made between pin 1 and pin3 as shown in Figure 8.

tecnare DMA 8X8 Dsp Matrix - fig7

3.4. ETHERNET port for programming and control
An RJ45 type (fig.9), 10/100 Base-T connector, allows connecting the equipment to an Ethernet network through an IP-based Windows application.

  • Management of Tecnare DSP Controller application. Please, refer to the Tecnare DSP Controller software manual for more information.
  • Possibility of direct connection (point-to-point) between a computer and a DMA 8X8 device.

3.4.1. Connecting the DMA 8X8 to the Tecnare DSP controller Software
Install the Tecnare DSP Controller software in your Computer and connect it on the same network of DMA 8X8.
Launch the software and go to “Device List” menu (fig.10) on the upper right corner, and wait while the connected DMA 8X8 appears.
In order to connect to the DMA 8X8 its IP address must be set in the same range as the network
IP address. By default it is configured with the IP address: 169.254.10.227. To change the IP address of the device, pressing “Set IP” from the “Device List” menu and set it according your network configuration. If it is already configured correctly, then make click on “Connect” and the software will sync with the DMA 8X8.

tecnare DMA 8X8 Dsp Matrix - fig8

Once the device has been connected and synchronized, you will be able to manage and configure all the system parámeters, identify every device connected to the network in real time together the digital wall panels as well as load and store presets.
Note: Please refer to the Tecnare DSP Controller Software for more information.

3.5. RS-232 Remote control Port
The built-in RS-232 port in the rear panel (fig.11) allows an external device to communicate with an DMA 8X8 unit via a serial connection.
The serial connection should comply with the following specifications:

Baud Rate: 115200 (default)
Data bits: 8
Parity: None
Stop bits: 1
Flow Control: None

Wiring RS232-DB9

RS232| | DB9
Tx| Sending or Data Output| Pin 2 (RxD)
Rx| Receiving or Data Input| Pin 3 (TxD)
GND| | Pin 5 (Signal GND)

3.6. RS-485 Remote control Port
The built-in RS-485 port in the rear panel (fig. 11), used for serial communication (Tx= sending or data output; Rx = receiving or data input) allows the communications with a third-party control device.
RS485 can be used for voice tracking control (or other output commands), or for bus input control. A central command can be used to conveniently integrate it into your software.

Baud Rate: 115200 (default)
Data bits: 8
Parity: None
Stop bits: 1
Flow Control: None

Wiring RS232-DB9

RS485| | DB9
A| Tx Data –| Pin 3 (TxD/RxD-)
B| Rx Data +| Pin7 (TxD/RxD+)
GND| | Pin 5 (Signal GND)

3.7. GPIO Remote Control Port
The rear panel of the DMA-8X8 offers 4-channels, logic input/output that allows independent input or output configuration.
Each input is a 0-5 VDC continuous control voltage, and can be connected to an external physical device.
Each output is a 0-5 NO/NC (normally open / normally closed) relay output. These outputs may be assigned by the logical output control module of the software. Polarity and threshold can be definde as well.

3.8. USB Soundcard
USB Soundcard is used for recording and broadcasting audio using personal computers.
The cable used is Type-B USB (Fig.13). For initial connection, “Found New Hardware” will pop up on computer  screen, and the driver will be installed automatically. After installation, USB sound card will appear in the computersoundcard list. Users may select USB soundcard in soundcard setting at software playlist.

tecnare DMA 8X8 Dsp Matrix - fig11

Typical Application Example

A capacitor microphone can be connected to the matrix, and this to an amplifier. Two kinds of remote controls can be daisy chained to various areas for personnel attending in preset setup, volume control, source selection and other functions can be performed  via UDP.

tecnare DMA 8X8 Dsp Matrix - fig12

Key Panel

The Control Panel must be connected to the system through Ethernet and supplied by PoE.
It has 8 keys and one rotary knob on key panel. The knob is used to adjust gain, and 8 keys can be used to set different functions through programming. These include volume adjustment, mute, preset and command. Configuration will be carried out through the software.

5.1. Operations

  1.  Key indicator stays on, which indicates the key is configured with mute function.
  2.  Key indicator keeps flashing, which indicate the key is configured with gain function. To set the gain, use the rotary knob. It can be set between -72dB and +12dB. 13 LEDs indicators around the rotary knob indicate gains.
  3.  A sudden flash happens when pressing the key indicator indicates the key is configured with preset or command function.

Oled Screen

The Control Panel must be connected to the system through Ethernet and supplied by PoE.
OLED Control Panel consists of a 1.3” OLED screen and one Encoder knob. OLED screen w ill show a classification based to a menu. There is a total of three types of items including menu, buttons and presets. Configuration will be carried out through the software.

6.1. Operations
4. It Display panel name and IP address on the screen. Turn the knob left or right to switch menu.
5. Press the encoder button, and the second row on the menu interface starts to flash, which indicates that it enters edit mode.
6. Turn the encoder left or right to change the value.

Technical Specifications

AUDIO

Input impedance
Output impedance
Input Gain
Input
Level
Max
Level
Frequency Response
THD+Noise
Dynamic Range
Background Noise (A-weighted)Channel Isolation
Phantom Power| 9.4 kΩ balanced
102 Ω balanced
0/6/12/18/24/30/36/42/48 dBu
0/-6dB
+24dBu
20Hz – 20kHz+/-0.2dB
0.003% @4 dBu
110 dB
-91 dB
108 dB @1kHz
+48V
---|---

INDICATORS, CONTROL & COMMUNICATIONS 

Front panel:
Monitoring facilities
Rear panel:
Network and control
Control Protocols| Power
Status
Ethernet
RS-232, RS-485 and UDP (transport layer)
---|---

DSP

Processor
Sample
Rate
Work Mode
System Delay| ADI SHARC 21489
48khz/24bits
Stereo, Bridge, Mono, Free Matrix
<3 ms
---|---

POWER SUPPLIES

Input voltage
Max Power Consumption| AC 230 v / 50-60 Hz nominal +/- 10% (110v optional using TRF-
<40 W
---|---

THERMAL

One variable speed fan. Airflow is from right to left.

PHYSICAL

Height
Width
Depth
Weight| 1HU, 44mm
482mm, 19” (front panel)
440mm, 17,32” (rear chassis)
200mm, 7,87” (behind rack)
3 Kgs, 6.61 pounds
---|---

CONNECTIONS

Mains
Audio input
Output
USB
Network and Com.| IEC-C14
2 x 12 pin Phoenix Terminal
2 x 12 pin Phoenix Terminal
Type B (peripheral type)
1x RJ45 socket; TCP/IP, 1000base-T/100base-TX
RS485/RS232 via 3 input/output Phoenix Terminal
GPIO via 6 input/output Phoenix Terminal
---|---

PANEL A-DMA8X8

Description
Control
Communication   Power Supply
Colour    Dimensions (WxDxH)
Shipping
weight|   Remote control
8 x button
1 x Rotatory button
Ethenet
PoE (not included)
White
96 x 33 x 156 mm
550g
---|---

PANEL B-DMA8X8

Description
Control
Communication
Power Supply
Colour    Dimensions (WxDxH) Shipping
weight|   Remote control
1 x Encoder button
Ethenet
PoE (not included)
White
550g
---|---

REGULATORY COMPLIANCE

This product complies with the EMC & LVD directives as issued by the Commission of the European Community.
Compliance with these directives implies conformity with the following European standards:

EN55103-1 Electromagnetic Interference (Emission)
EN55103-2 Electromagnetic Susceptibility (Immunity)
EN60065 Electrical safety
DMA8X8 also meets the requirements of FCC part 15B.

Reinventing The Rules
©2022
Tecnare Sound Systems. All rights reserved.
DMA 8X8 DSP MATRIX Operation manual
The contents of this manual are furnished for informational purposes only, are subject to change without notice, and should not be construed as a commitment by Exel Acoustics SL. Exel Acoustics assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual. Except as permitted by applicable copyright law, no part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, recording or otherwise, without prior written permission from Exel Acoustics. Tecnare and PCC-Net are trademarks of Exel Acoustics SL. System Engineer, BvNet and all third-party trademarks mentioned herein are the property of their respective trademark holders.
Printed in Spain.

EXEL ACOUSTICS SL
CL Encinar, 282 – Pol. Ind. Monte Boyal
45950 – Casarrubios del Monte (To) Spain
www.tecnare.comwww.facebook.com/tecnare
(T): +34 918 170 110 – +34 918 171 001
rev.1.1.2022

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals