tecnare DMA 8X8 Dsp Matrix User Manual
- June 13, 2024
- tecnare
Table of Contents
Operation Manual
Commercial Series
DMA 8X8
DSP MATRIX
Keep these important operatin instructions.
Check www.tecnare.com for updates
IMPORTANT SAFE INSTRUCTIONS
Before using our product, be sure to carefully read the manual and safe Instructions. Keep this document with the device all time.
-
Read these instructions
-
Keep these instructions.
-
Heed all warnings.
-
Follow all SAFETY INSTRUCTIONS as well DANGER and OBLIGATION warnings.
-
Only use attachments / accessories specified by Exel Acoustics SL.
-
Do not use this apparatus near water.
-
Clean only with dry cloth.
-
Do not block any ventilation openings. Install in accordance with Exel Acoustics’ instructions.
-
Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus (including amplifiers) that produce heat.
-
Do not defeat the safety purpose of the polarized or grounding type plug. A polarized plug has two blades with one more wide than the other. A grounding type plug has two blades and a third pin are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
-
Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles and the point where they exit from the apparatus.
-
Unplug this apparatus during lightning storms or when unused for long periods of time.
-
Refer all servicing to qualified service personnel. Service is required when the apparatus has been damaged in any way, such as power-supply cord or plug damaged, liquid has been spilled or objects have fallen into the apparatus, this apparatus has been x-posed to rain or moisture, does not operate normally, or has been dropped.
CAUTION: To reduce the risk of fire of electric shock, do not expose this device to rain or moisture. -
Use the mains plug to disconnect the device from mains.
-
Do not expose this equipment to dripping or splashing and ensure that no objects filled with liquids, such as vases, are placed on the equipment.
-
The mains plug of the power supply cord shall remain readily operable.
-
Do not connect the unit’s output to any other voltage source, such as battery, mains source, or power supply, regardless of whether the unit is turned on or off.
-
Do not remove the top (or bottom) cover. Removal of the cover will expose hazardous voltages. There are no user serviceable parts inside and removal may void warranty.
CAUTION: Do not remove any covers, loosen any fixings or allow items to enter any aperture
CAUTION: The rear of the product may get hot. Avoid direct skin contact during operation and for at least 5 minutes after power has been isolated.
CAUTION: The product must only be positioned at floor level when operated in a horizontal position. -
If the equipment is used in a manner not specified by the Exel Acoustics, the protection by the equipment may be impaired.
SYMBOL USED
Warning
This simbol indicate Risk of injury. It is essential to observe this warning.
Non-compliance can lead to serious injury or death.
Caution
This simbol indicate Personal injuries. It is essential to observe this
warning. Non-compliance can lead to minor or slight injury.
Notice
This simbol indicate Damage to the devices or environment. It is essential to
observe this warning. Non-compliance can lead to damage to property or
equipment or environmental damage.
tip or pointer
This simbol indicate information that contributes to better understanding.
STANDARDS
FOR CUSTOMERS IN EUROPE
This product complies with both the LVD (electrical safety) 73/23/EEC and EMC
(electromagnetic compatibility) 89/336/EEC directives issues by the commission
of the European community.
Compliance with these directives implies conformity with the following
European standards:
EN60065 Product safety
EN55103-1 EMC emissions
EN55103-2 EMC immunity
This product is intended for the following electromagnetic environments: E1,
E2; E3 & E4.
THIS PRODUCT MUST BE EARTHED. Use only a flexible cable or cord with a green
and yellow core which must be connected to the protective earthing terminal of
a suitable mains plug or the earthing terminal of the installation. The cord
must be a maximum of 2m long, have a 2.5mm2 CSA, a 300/500V rating and comply
with EN50525-2-11 / H05W-F.
THIS PRODUCT IS DESIGNED FOR PERMANENT INSTALLATION. It must be fitted in to a
19” rack enclosure and not operated unless so installed. The rack enclosure
should be open at the front and back to allow free ventilation and movement of
air through the product.
FOR CUSTOMERS IN THE USA
This product has been tested for electrical safety and complies with UL60065
7th edition THIS PRODUCT MUST BE EARTHED. Use only a flexible cable or cord
with a green or green / yellow core which must be connected to the protective
earthing terminal of a suitable mains plug or the earthing terminal of the
installation. The cord must be a maximum of 6’ long, be 14AWG, have a rating
SJ, SJT, SJE or 300/500VH05W-F and be marked VW-1.
THIS PRODUCT IS DESIGNED FOR PERMANENT INSTALLATION. It must be fitted in to a
19” rack enclosure and not operated unless so installed. The rack enclosure
should be open at the front and back to allow free ventilation and movement of
air through the product.
DECLARATION OF CONFORMITY WITH FCC RULES
We, EXEL Acoustics SL, CL Encinar 282, Pol. Ind. Monte Boya, 45950 –
Casarrubios del Monte (Toledo), España, declare under our sole responsibility
that this family of devices, complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
FEDERAL COMMUNICATIONS COMMISSION NOTICE An example of this equipment has been
tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential and
commercial installation.
This equipment generates, uses, and can radiate radio frequency energy, and if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try
and correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the distance between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate this
equipment.
FOR CUSTOMERS IN THE CANADA
This product complies with CA /CSA C22.2 No.60065-03
Ce produit est conforme avec CA /CSA C22.2 No.60065-03
THIS PRODUCT MUST BE EARTHED. Use only a flexible cable or cord with a green
or green / yellow core which must be connected to the protective earthing
terminal of a suitable mains plug or the earthing terminal of the
installation. The cord must be a maximum of 6’ long, be 14AWG, have a rating
SJ, SJT, SJE or 300/500V H05W-F and be marked VW-1.
THIS PRODUCT IS DESIGNED FOR PERMANENT INSTALLATION. It must be fitted in to a
19” rack enclosure and not operated unless so installed. The rack enclosure
should be open at the front and back to allow free ventilation and movement of
air through the product.
DECLARATION OF CONFORMITY WITH CANADIAN ICES-003
This Class B digital apparatus complies with Canadian ICES-003.
DECLARATION OF CONFORMITY
**** EXEL ACOUSTICS SL
Declare under our sole responsibility that the DMA 8×8 amplifier products
comply with relating Directives:
- Low Voltage Directive 2014/35/EU
- EMC 2014/130/EU
- RoHS Directive 2011/65/EU
- WEEE Directive 2012/19/EU
In compliance with these Harmonized European Norms:
- EN60065 8th. Audio, video and similar electronic apparatus. Safety requirements.
- EN55032:2012. EMC emissions & immunity.
- EN55035-2017
Welcome and unpacking
1.1. Welcome to Tecnare
Thank you for choosing a Tecnare® DMA 8X8 fully programmable digital audio
matrix for your apli- cation.
Please spare a little time to study the contents of this manual, so that you
obtain the best possible performance from this unit.
All Tecnare® products are carefully engineered for world-class performance and
reliability.
If you would like further information about this or any other Tecnare®
product, please contact us. We look forward to helping you in the near future.
As part of a continuous evolution of techniques and standards, Exel Acoustics
SL as manufacturer of Tecnare ® products reserve the right to change the
specifications of its products and the content of its docu- ments without
prior notice.
Updates and supplementary information are available on the Tecnare® website:
http://www.tecnare.com
Tecnare Technical Support is available at:
- (T): +34 918 170 110 – +34 918 171 001
- (e-mail): support@tecnare.com
Thank you again for placing your confidence in Tecnare® products.
1.2. Unpacking
After unpacking the unit please check carefully for damage. Every Tecnare
product is tested and inspected before leaving the factory and should arrive
in perfect condition. If damage is found, please notify the carrier concerned
at once. You, the consignee, must instigate any claim. Please retain all
packaging in case of future re-shipment.
1.3. The User Guide
This user manual gives a progressively more detailed description of the
functions of the Tecnare DMA 8X8 Matix processor.
A detailed explanation describes each individual function or feature with
annotated images explaining its use is contained in the next sections. Where
appropriate, the graphical display is shown to further elaborate on the unit
operation.
To complete the manual a reference section is included, describing the
technical performance and Mechanical drawing of the device.
Overview
2.1. Introduction
The DMA 8X8 is equipped with several core technical features to facilitate the
work of audio engineers. DSP-based remote audio equipment is routed, processed
and controlled by computer. The Tecnare DSP Controller is a Windows-based
application, which is used to conduct configuration and control of DSP
hardware. DSP Controller has 16 built-in presets, and the modules and
sequences for each preset can be flexibly designed in accordance with the
designer’s requirements. After the design is finished, it can be saved for
future use. The sequences and parameters of DSP Controller’s built-in
processing modules accord to most of the application scenarios without any
change. DSP Controller is a full-featured application, including the parameter
adjustment and peripheral acces- sory settings of all modules, such as RS232,
RS485, click-and-drag panel configuration and optional Dante network audio
control. The most interesting part is the user interface, which allows the
engineer to customize user interface so that the Integrator can edit it or the
on-site technicians or end users who have no idea of relevant techniques can
operate it. Superior safety functions make it possible for the end users to
access to the controls allowed by the engineer or designer.
2.2. Key features
-
DANTE® network audio optional
-
Network TCP / IP control, can realize management of multiple devices
-
8 balanced MIC/LINE inputs (independent phantom power per input channel)
-
8 balanced LINE outputs
-
Built-in ADI SHARC DSP 21489
-
4 GPIO control ports (General Purpose Input / Output)
-
Programming and remote management via Ethernet Using Tecnare DSP Controller (also point-to-point, with a direct CAT5 cable, or from an Ethernet network)
-
Remote control bus for DMA digital Panel
-
16 Configuration memory presets
-
Extensive DSP available:
◦ Routing matrix/mixer, from any input to any output with adjustable level, crossover points (in- dependent mixes of different inputs for each output)
◦ Link channel processing
◦ Level control, muter, meters, polarity and input sensitivity selector for inputs and outputs
◦ Internal signal generator ( sine, white and pink noise) for input
◦ Parametric EQ on inputs and outputs
◦ Expander, compressor, Auto Gain Control and Feedback Inhibition for each input channel
◦ Delay and limiter setting for each output channel
◦ Automixer -
USB Soundcard
2.3. Front and Rear Panel
2.3.1. The Front Panel and LED indicators
The DMA 8X8 system is designed to be mounted in a standard 19”/1HU rack
enclosure.
On the front panel, an LED (PWR) lights up when the unit is switched on. A second LED (STATUS) indicates the operation status of the device.
- Status LED indicator (STATUS):
◦ If the device is switched on and the device is configured, the LED continuously toggles between green and unlit even if it is not connected to Ethernet.
◦ If the device is switched on and it has been “reset to default” or “Restore to Factory Setting”, the LED would be on permanently.
2.3.2. The Rear Panel
The rear panel of the DMA 8X8 offers 8 balanced analogue signal inputs
accepting both line and mic level signals, 8 analogue signal output, an RJ45
type connector, a GPIO for 0-5 Vdc continuous control voltage,RS-232 & RS485
port, USB audio port and Power connector.
- Main socket: 230 Vac / 50Hz; 40W
- Ethernet Connector (RJ45): 10/100 Base-T Ethernet connector is used for IP-based PC Software and host and third-party accessory controller.
- GPIO: 6-bit 3.81mm terminal. 4 input/output contacts to be assigned to different functions.
- RS-485: Used as serial communication port A-B that’s connects to a third-party control device. The Port setting should comply with the following specifications: 115200 baud (default), 8 data bits, 1 stop bit, no parity, no flow control.
- RS-232: Used for the serial communication port Tx = sending or data output or Rx = receiving or data input that connects to a third-party control device. The Serial Port setting should comply with the following specifications: 115200 baud (default), 8 data bits, 1 stop bit, no parity, no flow control.
- USB Audio Port: USB soundcard (1-in-1-out), which can be used to play audio or for recording function.
- Signal Input & Output terminal: Signal input and output connectors are 3 position screw terminal block.
Connections
3.1. Audio Input Connections
The rear panel of DMA 8X8 offer 8 balanced analogue MIC/LINE inputs. It
features a couple of removable balanced 12 pin Phoenix terminal strips.
Analog input section supports microphone or line-level signals whit nominal levels of 0dBu, 10dBu, 20dBu, 30dBu, 40dBu and 43dBu. +48VDC phantom power can be adopted for each input. Preamp gain and phan-
tom power can be easily controlled through the Tecnare DSP Controller.
Fig. 5 Input source setting on the Tecnare DSP Controller Software
3.2. Audio Output Connections
The rear panel of DMA 8X8 offer 8 balanced analogue MIC/LINE inputs. It
features a couple of removable balanced 12 pin Phoenix terminal strips .
Unit gain (0dB) is set through volume control, and the analogue output section
is corrected to +4dBu with 20dB headroom. That is to say, 0dBFS digital signal
is equivalent to +24dBu output signal. If other signal levels are required,
you may change the volume to achieve it.
3.3. Audio Wiring Reference
- Balanced Connection
The HOT, + or ‘in phase’ connection should be made to pin + on the terminal
strips or pin 2 of the XLR connector.
The COLD, – or ‘out of phase’ connection should be made to pin – on the
terminal strips or pin 3 of the XLR connector.
GND Pin, corresponding with Pin 1 of the XLR connectors is internally
connected to the chassis.
The shield of the input cable should always be connected Pin 1 to ensure the
EMC performance and
Note: For one XLR interface, the female connects to the output device and the male connects to the input device.
- Using unbalanced connection
Please note that the use of unbalanced connections is not recommended, however when connecting the matrix to an unbalanced audio source, the signal conductor should be connected to XLR pin2. The ‘Cold’ conductor or cable screen should be connected to pin 1 with a short connection made between pin 1 and pin3 as shown in Figure 8.
3.4. ETHERNET port for programming and control
An RJ45 type (fig.9), 10/100 Base-T connector, allows connecting the
equipment to an Ethernet network through an IP-based Windows application.
- Management of Tecnare DSP Controller application. Please, refer to the Tecnare DSP Controller software manual for more information.
- Possibility of direct connection (point-to-point) between a computer and a DMA 8X8 device.
3.4.1. Connecting the DMA 8X8 to the Tecnare DSP controller Software
Install the Tecnare DSP Controller software in your Computer and connect it on
the same network of DMA 8X8.
Launch the software and go to “Device List” menu (fig.10) on the upper right
corner, and wait while the connected DMA 8X8 appears.
In order to connect to the DMA 8X8 its IP address must be set in the same
range as the network
IP address. By default it is configured with the IP address: 169.254.10.227.
To change the IP address of the device, pressing “Set IP” from the “Device
List” menu and set it according your network configuration. If it is already
configured correctly, then make click on “Connect” and the software will sync
with the DMA 8X8.
Once the device has been connected and synchronized, you will be able to
manage and configure all the system parámeters, identify every device
connected to the network in real time together the digital wall panels as well
as load and store presets.
Note: Please refer to the Tecnare DSP Controller Software for more
information.
3.5. RS-232 Remote control Port
The built-in RS-232 port in the rear panel (fig.11) allows an external
device to communicate with an DMA 8X8 unit via a serial connection.
The serial connection should comply with the following specifications:
Baud Rate: 115200 (default)
Data bits: 8
Parity: None
Stop bits: 1
Flow Control: None
Wiring RS232-DB9
RS232| | DB9
Tx| Sending or Data Output| Pin 2 (RxD)
Rx| Receiving or Data Input| Pin 3 (TxD)
GND| | Pin 5 (Signal GND)
3.6. RS-485 Remote control Port
The built-in RS-485 port in the rear panel (fig. 11), used for serial
communication (Tx= sending or data output; Rx = receiving or data input)
allows the communications with a third-party control device.
RS485 can be used for voice tracking control (or other output commands), or
for bus input control. A central command can be used to conveniently integrate
it into your software.
Baud Rate: 115200 (default)
Data bits: 8
Parity: None
Stop bits: 1
Flow Control: None
Wiring RS232-DB9
RS485| | DB9
A| Tx Data –| Pin 3 (TxD/RxD-)
B| Rx Data +| Pin7 (TxD/RxD+)
GND| | Pin 5 (Signal GND)
3.7. GPIO Remote Control Port
The rear panel of the DMA-8X8 offers 4-channels, logic input/output that
allows independent input or output configuration.
Each input is a 0-5 VDC continuous control voltage, and can be connected to an
external physical device.
Each output is a 0-5 NO/NC (normally open / normally closed) relay output.
These outputs may be assigned by the logical output control module of the
software. Polarity and threshold can be definde as well.
3.8. USB Soundcard
USB Soundcard is used for recording and broadcasting audio using personal
computers.
The cable used is Type-B USB (Fig.13). For initial connection, “Found New
Hardware” will pop up on computer screen, and the driver will be installed
automatically. After installation, USB sound card will appear in the
computersoundcard list. Users may select USB soundcard in soundcard setting at
software playlist.
Typical Application Example
A capacitor microphone can be connected to the matrix, and this to an amplifier. Two kinds of remote controls can be daisy chained to various areas for personnel attending in preset setup, volume control, source selection and other functions can be performed via UDP.
Key Panel
The Control Panel must be connected to the system through Ethernet and
supplied by PoE.
It has 8 keys and one rotary knob on key panel. The knob is used to adjust
gain, and 8 keys can be used to set different functions through programming.
These include volume adjustment, mute, preset and command. Configuration will
be carried out through the software.
5.1. Operations
- Key indicator stays on, which indicates the key is configured with mute function.
- Key indicator keeps flashing, which indicate the key is configured with gain function. To set the gain, use the rotary knob. It can be set between -72dB and +12dB. 13 LEDs indicators around the rotary knob indicate gains.
- A sudden flash happens when pressing the key indicator indicates the key is configured with preset or command function.
Oled Screen
The Control Panel must be connected to the system through Ethernet and
supplied by PoE.
OLED Control Panel consists of a 1.3” OLED screen and one Encoder knob. OLED
screen w ill show a classification based to a menu. There is a total of three
types of items including menu, buttons and presets. Configuration will be
carried out through the software.
6.1. Operations
4. It Display panel name and IP address on the screen. Turn the knob left or
right to switch menu.
5. Press the encoder button, and the second row on the menu interface starts
to flash, which indicates that it enters edit mode.
6. Turn the encoder left or right to change the value.
Technical Specifications
AUDIO
Input impedance
Output impedance
Input Gain
Input
Level
Max
Level
Frequency Response
THD+Noise
Dynamic Range
Background Noise (A-weighted)Channel Isolation
Phantom Power| 9.4 kΩ balanced
102 Ω balanced
0/6/12/18/24/30/36/42/48 dBu
0/-6dB
+24dBu
20Hz – 20kHz+/-0.2dB
0.003% @4 dBu
110 dB
-91 dB
108 dB @1kHz
+48V
---|---
INDICATORS, CONTROL & COMMUNICATIONS
Front panel:
Monitoring facilities
Rear panel:
Network and control
Control Protocols| Power
Status
Ethernet
RS-232, RS-485 and UDP (transport layer)
---|---
DSP
Processor
Sample
Rate
Work Mode
System Delay| ADI SHARC 21489
48khz/24bits
Stereo, Bridge, Mono, Free Matrix
<3 ms
---|---
POWER SUPPLIES
Input voltage
Max Power Consumption| AC 230 v / 50-60 Hz nominal +/- 10% (110v optional
using TRF-
<40 W
---|---
THERMAL
One variable speed fan. Airflow is from right to left.
PHYSICAL
Height
Width
Depth
Weight| 1HU, 44mm
482mm, 19” (front panel)
440mm, 17,32” (rear chassis)
200mm, 7,87” (behind rack)
3 Kgs, 6.61 pounds
---|---
CONNECTIONS
Mains
Audio input
Output
USB
Network and Com.| IEC-C14
2 x 12 pin Phoenix Terminal
2 x 12 pin Phoenix Terminal
Type B (peripheral type)
1x RJ45 socket; TCP/IP, 1000base-T/100base-TX
RS485/RS232 via 3 input/output Phoenix Terminal
GPIO via 6 input/output Phoenix Terminal
---|---
PANEL A-DMA8X8
Description
Control
Communication Power Supply
Colour Dimensions (WxDxH)
Shipping
weight| Remote control
8 x button
1 x Rotatory button
Ethenet
PoE (not included)
White
96 x 33 x 156 mm
550g
---|---
PANEL B-DMA8X8
Description
Control
Communication
Power Supply
Colour Dimensions (WxDxH) Shipping
weight| Remote control
1 x Encoder button
Ethenet
PoE (not included)
White
550g
---|---
REGULATORY COMPLIANCE
This product complies with the EMC & LVD directives as issued by the
Commission of the European Community.
Compliance with these directives implies conformity with the following
European standards:
EN55103-1 Electromagnetic Interference (Emission)
EN55103-2 Electromagnetic Susceptibility (Immunity)
EN60065 Electrical safety
DMA8X8 also meets the requirements of FCC part 15B.
Reinventing The Rules
©2022
Tecnare Sound Systems. All rights reserved.
DMA 8X8 DSP MATRIX Operation manual
The contents of this manual are furnished for informational purposes only, are
subject to change without notice, and should not be construed as a commitment
by Exel Acoustics SL. Exel Acoustics assumes no responsibility or liability
for any errors or inaccuracies that may appear in this manual. Except as
permitted by applicable copyright law, no part of this publication may be
reproduced, stored in a retrieval system, or transmitted, in any form or by
any means, electronic, mechanical, recording or otherwise, without prior
written permission from Exel Acoustics. Tecnare and PCC-Net are trademarks of
Exel Acoustics SL. System Engineer, BvNet and all third-party trademarks
mentioned herein are the property of their respective trademark holders.
Printed in Spain.
EXEL ACOUSTICS SL
CL Encinar, 282 – Pol. Ind. Monte Boyal
45950 – Casarrubios del Monte (To) Spain
www.tecnare.com –
www.facebook.com/tecnare
(T): +34 918 170 110 – +34 918 171 001
rev.1.1.2022