VEVOR 33 Digital Double Door Safe Depository Box Owner’s Manual
- June 13, 2024
- VEVOR
Table of Contents
VEVOR 33 Digital Double Door Safe Depository Box
Product Functional Description
- Yellow light: Input digital indicator light
- Green light: Door opening indicator light
- Red light: Under-pressure indicator light
- Static current: Below 10UA
- Dynamic current: 360MA
- Under-voltage voltage: 4.5V (+/-0.2V)
- Normal operating voltage: 4-7V
- No password memorization function
Picture description
-
Open the emergency key cover
-
Insert the emergency key, urn it counterclockwise, and turn the Knob clockwise to open the door
-
Push the battery cover upward, install the battery an pay attention to the positive and negative pole
-
Press the reset key to set
-
The yellow light is on for a long time, input 3~8 digit password and Press”#(B)”to confirm
Functional Description
- Yellow light is an input digital indicator light; The green light is the door opening indicator light; a red light is an under-pressure indicator light.
- The static current is below 10UA.
- dynamic current is 360MA.
- the under-voltage voltage is 4.5V (+/-0.2V)
- normal operating voltage: 4-7V
- The system has no password memorization function.
Two: open the door:
When entering the correct 3-8-bit password, press B(#), the buzzer “dripping”,
green light 6S, electromagnet suction 6S.
Note: after entering the wrong password, the buzzer rang “three downs” and the yellow light flashed three times, indicating that the input password was incorrect.
Three : set the password;
- When setting the customer password, press the code change button, the yellow light shines twice, and the buzzer rings twice at the same time, then enter a 3-8-bit password. After pressing B(#) to confirm, the buzzer rang twice, and the yellow light shines twice and goes out. Represents the success of setting.
- When setting the main password, enter “00”, then press the code change button, enter the 3-8-bit password. After pressing B(#) to confirm, the buzzer rang twice and the yellow light flashed twice and extinguished.
- Represents the success of setting.
Four: the self-locking function of lost passwords:
- Enter the wrong password three times in a row, the password lock will be automatically locked for 20 seconds, and the buzzer alarm will be alarmed.
- Enter the wrong password six times in a row, the password lock will be locked for 5 minutes, and the buzzer will ring.
Note : during the self-locking process, any key input is unresponsive.
Six: under-pressure function:
When the voltage is 4.5V (+/-0.2), the indicator light turns on and warns to
replace the battery.