LiftMaster 771EVK Safety Light Barrier Instruction Manual

August 29, 2024
LiftMaster

LiftMaster 771EVK Safety Light Barrier

INSTALLATION INSTRUCTION

LM60EV / LM80EV / LM100EV / LM130EV-/ EVS / EVF

LM50EV / LM55EV-/ EVS / EVF

LM3800W

LM750EVGB

LM600A / LM800A / LM1000A

LM60

3780 / 5580

WARNING

Non-compliance with the checking and adjustment requirements for the safety reverse system can result in a closing door causing serious, life-threatening injuries. An appropriate test should be carried out and repeated every month. If necessary, the sensors need to be readjusted- ted. The product complies with the essential requirements and other relevant provisions of the Directives 2004/108/EC and 2006/95/EC. The CE Declaration of Conformity can be obtained from info@chamberlain.com

INSTALLATION – GARAGE DOORS

The transmitter lens transmits an invisible beam of light to the receiver lens. When the light beam is interrupted during the closing process, the door stops and re-opens completely. This installation method is the same for vertically opening sectional doors and canopy doors. The CB3 control unit permits the connection of two pairs of light barriers (opening & closing). In such cases, one pair of sensors can be installed at the sides of the door on both the inside and outside (fig. 3). However, the sensors must be mounted and connected in such a way that the transmitter and receiver lens are located exactly opposite each other as shown in (fig. 3). The sensors must be mounted securely to a solid surface, such as the posts or wall on both sides of the door. The invisible beam of light may not be interrupted. No part of the garage door (e.g. door rails, springs, hinges, rollers, other hardware, etc.) may interrupt the beam during the closing process. If this is not possible, an upright column element (accessory) has to be ordered. For the protection of infants and small children, the safety light barrier should not be installed higher than 150 mm-200 mm above the garage floor.

ASSEMBLY/MOUNTING

The power supply must be disconnected before assembling/mounting the safety light barrier.

  1. Open housing as shown in fig. 1.
  2. Align the sensor such that the lens is located laterally to the door and point exactly at each other.
  3. Fasten sensors in place with screws/plugs.
  4. Inside the garage, use insulated staples to fasten the cable to the wall and ceiling. Outdoors, only use cable approved for such applications and, if necessary, run it through an empty tube. High voltage and low voltage may not be run together through one cable as this may disrupt the sensors. Ensure that the sensors are sufficiently watertight and that the rubber gasket is used for cable connections.
  5. Connect the cable (min. 2 x 0.25mm²) to the terminals as shown depending on the given control unit (figs a-g).
  6. Connect the power supply to the opener.
    • The two indicators, both in the transmitter lens and the receiver lens should light up if the terminal connections and alignment are correct.
    • Should the light indicators flash (if the invisible light beam is blocked), the sensors need to be aligned. Loosen the receiver lens housing such that the sensor can be moved slightly. Adjust the sensor vertically and/or horizontally until the red indicator lights up and stops flashing. Washers or the like may have to be fitted.

CHECKING THE SAFETY LIGHT BARRIER

  • Press the key on the remote control or the switch to open the door.
  • Place a sufficiently large obstacle under the door (see fig. 2 as an example) such that the sensor beam in the doorway is interrupted.
  • Press the key on the remote control or the switch to close the door. The garage door opener/door does not close when activated via the remote control if the light indicator in one of the sensors is flashing (which means that the sensor is incorrectly aligned or blocked by an obstacle). Consult a specialist in cases where the opener closes the door despite its path being blocked by an obstacle.

TROUBLESHOOTING

  1. In cases where the transmitter or receiver indicator light does not light up after installation, please check the following:
    • Power supply to opener.
    • Short circuit in the cable. This can occur under fasteners or at the connection terminals.
    • Incorrect cable connection between sensor and opener.
    • Interruption of circuit (interrupted connection).
    • The polarity of the cable wrong way round.
  2. In cases where both sensors are flashing:
    • Align sensors or remove obstacles.

You must ensure that the signal from the light barrier recognizes the presence of persons or objects (vehicles). Without additional safety precautions, the sensors do not guarantee total safety.

  • Safety class : IP44
  • Temperature range : – 40°C + 60°C
  • Current consumption : max. 20mA
  • Range : 10m

The product complies with the essential requirements and other relevant provisions of the Directives 2004/108/EC and 2006/95/EC. The CE Declaration of Conformity can be obtained from info@chamberlain.com

Read User Manual Online (PDF format)