Ningbo Sunvot Technology Co Ltd LC600-202302 4G LTE CPE Router User Guide
- June 13, 2024
- Ningbo Sunvot Technology Co Ltd
Table of Contents
- Ningbo Sunvot Technology Co Ltd LC600-202302 4G LTE CPE Router
- Product Information
- Product Usage Instructions
- FC192C RF Radiation Exposure Statement
- Overview
- Operator Device Specification
- Getting Started
- System Information
- FAQ and Troubleshooting
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Ningbo Sunvot Technology Co Ltd LC600-202302 4G LTE CPE Router
Product Information
-
Model: Sunvot LC600 LTE CPE
-
Device Specification: IDU (Integrated Device Unit)
-
Description: The Sunvot LC600 LTE CPE is a high-speed wireless router with multiple connectivity options. It features a user-friendly interface for easy setup and management.
User Interface
- 1 RJ45 10/100/1000M WAN Port (PoE)
- 2 RJ45 10/100/1000M LAN Ports
- 1 RJ11/FXS Line
Product Usage Instructions
Note: Before using the Sunvot LC600 LTE CPE, please read and understand the following instructions carefully.
Placement
To comply with FCC exposure guidelines, it is recommended to place the
product at least 20cm away from nearby persons.
Interference
High power radars operating in the 5.25 to 5.35 GHz and 5.65 to 5.85 GHz
bands may cause interference or damage to this device. Please ensure that no
radar stations are within close proximity to the Sunvot LC600 LTE CPE.
Frequency Configuration
This wireless equipment does not provide configuration controls for
changing the frequency of operation. It operates within the FCC grant of
authorization for US operation according to Part 15.407 of the FCC rules.
Quick Start Guide
Please refer to the Sunvot LC600 LTE CPE Quick User Guide v1.0 for detailed
instructions on setting up and using the device.
FCC Statement
The Sunvot LC600 LTE CPE complies with FCC regulations. For more
information, refer to the FCC Statement in the user manual.
Technical Support
If you encounter an issues or have questions regarding the Sunvot LC600 LTE
CPE, please contact our technical support team using the provided contact
details.
FCC Statement
Warning: Changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications.
However, there is no guarantee that interference will not occur in a
particular install Suation. If this equipment does cause harmful interference
to radio or television rece -0ption, whi7 ch can be determined by turning the
equipment off and on, the user is encourage-0d to try to correct the
interference by one or more of the following measures
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and r.leceiiuver.
- Connect the equipment into an outlet on a circuist dioffnerent from that to which the receiver is connected.
- Consult the dealer or an experienced radio39 /TV technician for help
The device must not be co-located65 or opera-A ting in conjunction with any
other antenna or transmitter.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions
- this device may not cause harmful interference, and
- this device must accept an68.y interference received, including interference that may cause undesired operation.
FC192C RF Radiation Exposure Statement
Caution: To maintain compliance with the FCC’s RF exposure guidelines,
place the product at least 20cm from nearby persons.
High power radars are allocated as primary users of the 5.25 to 5.35 GHz and
5.65 to 5.85 GHz bands. These radar stations can cause interference with
and/or damage this device. No configuration controls are provided for this
wireless equipment allowing any change in the frequency of operations outside
the FCC grant of authorization for US operation according to Part 15.407 of
the FCC rules .
Overview
The LC600 CPE is a highly advanced LTE outdoor multi-service product solution specifically designed to meet integrated data, voice and Wi-Fi access needs for residential, business and enterprise users. The product consists of an outdoor data CPE unit (ODU) and an indoor multi service gateway unit (IDU) that supports advanced networking, VoLTE gateway and WLAN AP functionalities. It enables wide service coverage and provides high data throughput and networking features to customers who needs easy broadband access, low-cost VoLTE service and Wi-Fi connectivity.
Operator Device Specification
Model | Description & User Interface |
---|---|
**IDU** |
- 1 RJ45 10/100/1000M WAN Port(PoE), 2 RJ45 10/100/1000M LAN Ports ,1 RJ11/FXS Line
- SYS, NET, RF(Tri color)
- 2.4G Wi-Fi, 5G Wi-Fi, LAN1-2, LINE
- 48V/0.5A DC
- Dimensions: 152 mm (L) × 143 mm (W) × 39.6mm (D)
- Weight: < 350g
ODU
|
- **** 1 RJ45 10/100/1000M LAN Port
- SYS, SIM, ETH, RF (3 LEDs)
- 48V/0.5A PoE supply, ODU Power <15 Watts
- Dimensions: 276.17 mm (L) × 168.95 mm (W) × 80.45 mm (D)
- Weight: <1.5 Kg
Radio Interface Specification (ODU)
Frequency Bands | B2/4/5/28/40/42/43/48 |
---|---|
Radio Access | 3GPP Release 12 |
Operation Mode | TDD/FDD, 4 X 4 DL MIMO |
Output Power | 23 ± 2dBm |
Throughput | Category 12 |
SIM Support | SIM card slot (2FF) |
Wi-Fi Interface (IDU)
Radio Access | 802.11a/b/g/n/ac (2.4GHz 300 Mbps, 5GHz 867Mbps) |
---|---|
Output Power | 2.4G 2×2 20dBm, 5G 2×2 22dBm |
Antenna | built-in 4 antennas, 2×2 2.4G 2-3dBi, 2×2 5G 4-5dBi |
Security | WPA / WPA2, WPA-PSK/ WPA2-PSK encryption, WPA3 |
Getting Started
Packing list and CPE Unit
Upon receiving the product, please unpack the product package carefully. Each
product is shipped with the following items:
Table. Packing List
CPE Products | Quantity |
---|---|
ODU unit | 1 |
IDU unit | 1 |
Clamp | 2 |
Non-slip mat | 2 |
Waterproof Joint | 1 |
24V DC Power adapter | 1 |
Ethernet Cable | 1 |
If you find any of the items is missing, please contact our local distributor immediately.
Installing and power on
For outdoor CPE product, it is suggested that the CPE device be installed in
-a 07 shaded area to avoid direct sun light exposure and prolong the device
life.
To power on the device, the CPE must use a 48V DC power supply ad202apter. The
power adapters can operate in 90-250V AC range and therefore can be used iun
different country. An Ethernet cable is required to connect the WAN port of
IDU with the .POlE(LAN) port of ODU. By the way, the ODU don’t support the
hot-plugging. Once the device sois powered up, the user should wait for about
2 minutes before the device becomes operati Jonal. For CPE with the SYS LED
indicator, a solid light indicates the system has completed 3the 9startup
procedure.
To connect PC, LAN switch or other 5type -Aof9 IP device to the CPE product,
the user should use standard CAT6 Ethernet cable anDd -6connect to the
appropriate LAN port. Once connected, the CPE(IDU) LAN LED indicatorB- shouAld
be on.
To use the phone serv1ice,0 -operator can simply plug the phone line to the
CPE RJ11 port in the back. If the line is 5 not registered or configured, a
fast-busy tone will be provided and the corresponding LI0.NE LED light will be
off.
Insert SIM Card
Installing Outdoor
Un 10- it (ODU) – Pole installation
Use the brack0et .for6 5pole installation and fix it with screws, then use the
hoop to fix the device on the pole
LED Display
Type| ****
LED
| ****
Function
| ****
Description
---|---|---|---
IDU
| SYS| Power indicator| Green color – Device is powered on.
NET| WAN port status| Blinking green – The data is in transmission.
SIG| RF signal indicator| yellow: RSRP < -100dBm
blue: -100dBm <= RSRP < -80dBm Green: -80dBm <= RSRP
2.4G & 5G| Wi-Fi indicator| Light is on –2.4G & 5G Wi-Fi is on.
LAN1&LAN2| LAN port status| Solid green – LAN port is up.
Blinking green – LAN data activity in progress.
Line| POTS line status| OFF – Line is not registered or
provisioned. Green Color – The line is ready and registered Green Blinking –
Voice Call in progress
| WPS| WPS status indicator| OFF: Not enable MESH, or MESH
connect fail.
ON: MESH connect success
Flicker 1time/1s : MESH connecting
Type| LED| Function| Description
---|---|---|---
ODU| SYS| Power indicator| Solid green – Device is power on.
Type| LED| Function| Description
---|---|---|---
| ****
**** SIM
| ****
SIM card indicator
| Light off – No SIM
Light is on – Light on is for 20 seconds after SIM card state is ready
Slow Blinking– LTE/3G Network data transmission, 2 times blinking each second
Quick Blinking – SIM card is error. 5 times blinking each second
ETH| LAN port status| Blinking Green – LAN data transmission.
RF| RF Signal Strength| OFF – No wireless connection is
established RF1: RSRP < -100dBm
RF1 & RF2: -100dBm <= RSRP < -80dBm RF1 &RF2&RF3: -80dBm <= RSRP
Managing CPE Device
The LC600 offers rich management features which facilitate the task of service
7 provider. It supports local management access, Telnet, WEB, and centralized
remote 2OT-A configuration, upgrades management and device monitoring via
standard TR-069 ACS 3s-ystems. The following describes the basic procedures
for configuring the device for LTE op2erat0ion.
WEB Login
It is a preferred to setup the CPE using a Web browser strong. a local PC
connected to device LAN port. The operator should ensure that the connected
JPaC has acquired IP address via DHCP from the device. After IP connectivity
is established 39 between the PC and CPE device, the operator may launch a Web
browser and specify httA9p:/-/192.168.1.1 in the address bar. A window will
pop up requesting password. Input the u6ser 5l-ogin password and then click
the “Log in” button. After successful log on, the default hoAmDe -page of the
WEB GUI interface will appear. Note the default password is “admin”.
System Information
System Status
The menu shows the general system info of the CPE device. It includes system,
general, WAN, LAN, Wi-Fi information.
FAQ and Troubleshooting
Problem | Suggested Solution |
---|---|
My PC cannot connect to the CPE. |
- Re-plug the PC Ethernet cable and check if the PC LAN connection is up or showing activity.
- Check if the CPE Power is on. If it is not, check the power cord and make sure it is connected properly. Also verify that the AC power supply is available.
- If the PC LAN shows no activity and POE adapter LED is off but the power cord and ETH cable are connected properly and there is AC supply, then it is likely the POE adapter is damaged. Please contact distributor to obtain replacement part.
My PC cannot acquire IP from the CPE.|
- First check if the Network card is up and working properly. Then check the PC Network card configuration and make sure the DHCP is enabled.
- To release and renew the correct IP address, please unplug the Ethernet cable from PC and wait for about 5 seconds, then connect it again.
- If the problem persists, please contact the operator or distributor for
| further diagnose.
---|---
My CPE networking is not working properly.|
- You may want to check if the LTE connection is up and running properly. You can do this by login the WEB GUI and check the Interface Info page.
- You may want to perform a factory reset and see if the problem is being corrected. You can do this by log into the WEB GUI using “admin” password and perform restore the unit to default factory setting.
- If the problem cannot be corrected by factory reset, please contact the operator or distributor for further diagnose.
I forget the login password and like to reset the unit to factory default.|
- User can hold the IDU RESET button between WAN port and DC port for 10 seconds with power on to clear and reset the unit to factory default setting.
- After the unit is reset to factory default, you can login using the default password.
E-mail: Support@sunvot.com
Manufacturer: Ningbo Sunvot Technology Co., Ltd
Address: Building 3, NO 55 Longtan Shan Road, Beilun Da.qlii, Ningbo,
Zhejiang,China
Website: https://www.sunvot.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>