Welcome

Thank you and congratulations for choosing to purchase a Dimplex fireplace.

Please carefully read and save these instructions.

WARNING: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible electric shock, fire hazard and will void the warranty.

Please record your model and serial numbers for future reference. Model and serial numbers can be found on the label located at the top right corner inside the fireplace.

WARNING: Read all instructions and warnings carefully before starting installation. Failure to follow these
instructions may result in a possible electric shock, fire hazard and will void the warranty.
Please record your model and serial numbers for future reference. Model and serial numbers can be found on the
label located at the top right corner inside the fireplace.

Model: ____
MOD: ____
Serial Number: ____
Overview

IMPORTANT INSTRUCTIONS

When using any electrical appliance, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons. These precautions include:

  1. Read all instructions before using this electric fireplace.

  2. This fireplace is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. The trim around the heater outlet becomes hot during heater operation.
    DANGER: High temperatures may be generated under certain abnormal conditions. Do not partially or fully cover or obstruct the front of the fireplace.

  3. Extreme caution is necessary when the fireplace is used by or near children or people with disabilities and whenever the fireplace is left operating and unattended.

  4. Always turn off the fireplace when it is not in use.

  5. Do not operate the fireplace after it malfunctions, has been dropped, or damaged in any manner. Disconnect power at the service panel and have the fireplace inspected by a reputable electrician before using.

  6. Do not operate any unit with a damaged cord or if the heater has malfunctioned, or if the heater has been dropped or damaged in any manner, contact Glen Dimplex Americas Technical Service at 1-888-346-7539.

  7. Do not use this fireplace outdoors.

  8. Never locate the fireplace where it may fall into a bathtub or other water container.

  9. To disconnect the heater, turn the unit off with the controls and turn off the power to the heater circuit at the main disconnect panel.

  10. Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock, fire, or damage to the fireplace.

  11. To prevent a possible fire, do not block air intakes or exhaust in any manner.

  12. All electrical heaters have hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or flammable liquids are used or stored.

  13. Do not modify this fireplace. Use it only as described in this manual. Any other use may cause fire, electric shock, or injury to persons.

  14. Always use a certified electrician should new circuits or outlets be required.

  15. Always use properly grounded, fused and polarized outlets.

  16. Disconnect all power coming to the fireplace at the main service panel before performing any cleaning, maintenance, or relocation of the unit.

  17. When transporting or storing the fireplace, keep it in a dry place, free from excessive vibration, and store to avoid damage.

  18. Regular cleaning and maintenance is required to ensure safe and correct operation.

! NOTE: Changes or modifications not expressly approved by the party responsible for compliance could void user’s authority to operate the equipment.

SAVE THESE INSTRUCTIONS

  CAUTION
RISK OF ELECTRIC SHOCK DO NOT OPEN NO USER-SERVICEABLE PARTS INSIDE

FCC Compliance

CAUTION: This unit has been tested and found to comply with the limits for Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This unit generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio or television reception, which can be determined by turning the unit OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the unit and the receiver.

Connect the unit into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

This unit complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:

  1. This unit may not cause harmful interference, and
  2. this unit must accept any interference received, including interference that may cause undesired operation.

FCCCAUTION: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.

WARNING: This product can expose you to chemicals including nickel which is known to the State of California to cause cancer. For more information, visit www.P65Warnings.ca.gov

Conventions used in this manual:

! NOTE: Procedures and techniques that are considered important enough to emphasize.

CAUTION: Procedures and techniques which, if not carefully followed, will result in damage to the equipment.

WARNING: Procedures and techniques which, if not carefully followed, will expose the user to the risk of fire, serious injury, or death.

Technical Specifications

Electrical Rating

Voltage: 120 V (3-Wire) or 240 V (4-Wire)

Power:

Model 120 V 240 V No heat (120 V)
OLF46-AM 1220 W 1920 W 520 W
OLF66-AM 1480 W 2180 W 760 W

! NOTE: For OLF86-AM, when connected to 120 V, there will be no heat output, but heat functions will be active on the controls with only fans operating.

UL Listing
File Number: E71416

Model Reference

OLF46-AM| 6911540100
OLF66-AM| 6911540200
OLF86-AM| 6911540300

Product Dimensions

Product Dimensions

Model A B
OLF46-AM 47 1/2″      1206 mm 46 1/8″
OLF66-AM 67 1/2″      1714 mm 66 1/8″

Package Contents

Image

| Description| Quantity
---|---|---
OLF46-AM| OLF66-AM| OLF86-AM
Package Contents| Firebox| 1| 1| 1
Package Contents| Front Glass| 1| 1| 1
| Bag of Small Acrylic Crystals| 2| 3| 4
| Bag of Large Acrylic Crystals| 1| 1| 2
| Bag of Extra-Large Acrylic Crystals| 1| 1| 1
Package Contents| Driftwood| 8| 12| 15
| Spare Transducer Keep it in a secure location for future use.| 2| 3| 4
| Suction Cup Do not dispose of the suction cup after installation. Keep it in a secure location as it will be helpful for maintenance and service of the unit.| 2| 2| 2
Package Contents| Remote ControlIncludes two 3 V batteries| 1| 1| 1
| User’s and Installation Guide| 1| 1| 1
| Breakable Flame Baffles| 4| 6| 8
Package Contents| Slotted Flame Baffles| 6| 9| 12
| Bubble Level| 1| 1| 1
| 1 1/2″ Wood Screws| 4| 4| 4

*Package contents are subject to change

Installation

Placement

! NOTE: For optimized viewing angle of the flame, it is recommended that the bottom of the unit be mounted between 5″ (13 cm) and 50″ (127 cm) from the ground. (Figure 2)
Installation

Installation in a Bathroom

If this unit is installed in a bathroom, it must be protected by a GFCI receptacle or circuit. If a receptacle is used, it must be readily accessible.

This electrical appliance is NOT watertight. To prevent electric shock, it must be installed as to prevent water from entering unit, or installed away from showers, tubs, etc. Never locate fireplace where it may fall into a bathtub or other water container.

Installation Recommendations for Overhanging Objects
For overhanging temperature-sensitive objects, such as a television, a mantel, or artwork, always follow the recommendations provided by its manufacturer for installation over a heater.

Fresh Air Inlets

CAUTION: Failure to include a fresh air inlet will result in poor flame performance and damage to the fireplace. A fresh air inlet is required. The air inlet must allow for the air path to reach the underside of the unit. This will have to be accounted for in the framing and drywall installation. See the table below for air inlet requirements for each model. See Figure 3 for examples on incorporating fresh air inlets in the installation.

If the air inlet is concealed using a grille, the covered area must be compensated for by having a larger opening.

Model Air inletarearequired
OLF46-AM 80 in²
OLF66-AM 120 in²
OLF86-AM 160 in²

Recessed Inlet
Recessed Inlet
Front Register
Front Register
Side Registers

  • For best results in this configuration include an opening on each side of the fireplace
    Side Registers

Preparing the Firebox for Installation

  1. The unit is provided with mounting brackets attached (Figure 4). Remove the mounting brackets before installation. They will need to be reinstalled during installation once the firebox is placed into the framing.
  2. If using the plug accessory kit (OLFPLUG, sold separately), wire it following the instructions for the plug kit in the Electrical Installation section (page 14).
  3. For permanent heat disable only: follow the instructions for disconnecting the heat function in the section Heater Hardware Disconnect (page 16).
    Firebox for Installation

Framing

  1. Prepare a wall with a framed opening, following the dimensions in the table below. Openings beneath the unit are required in order to allow for airflow to reach the underside of the unit. (Figure 6)

Model| Width (minimum)| Height| Depth (minimum)| Width| Height
---|---|---|---|---|---
A| B| C| D| E
OLF46-AM| 48″1219 mm|

31 3/4″806 mm

|

12″305 mm

| 46 3/16″1174 mm|

17 ½”445 mm

OLF66-AM| 68″1727 mm| 66 3/16″1682 mm
OLF86-AM| 88″2235 mm| 86 3/16″2190 mm

CAUTION: This fireplace is NOT load-bearing. Ensure the opening for the fireplace is framed in such a way that
the weight of the building materials will not create pressure on the top of the fireplace.

! NOTE: Field wiring is located at the top right back corner of the firebox. The connection to water supply is
located at the bottom left back corner of the firebox. Plan the framing to allow routing the electrical power cable and the cold-water line to this location.

! NOTE: Ensure the unit is level and flush with the framing.
Installation
Installation

Installation Instructions

! NOTE: Two people are recommended for installation.

  1. Follow the instructions in the section Preparing the Firebox for Installation (page 10) before beginning.

  2. Prepare a wall with a framed opening, following the dimensions in the Framing section (page 11).
    CAUTION: Ensure there is an air inlet with a path for air flow to reach the underside of the unit.

  3. Place the firebox into the framed opening. Ensure the unit is level. A bubble level is included in the hardware kit provided.

  4. Secure the firebox to the frame using the previously removed mounting brackets. The unit must besecured to the frame with the mounting brackets.
    ! NOTE : To avoid bulging of the finished surface, notch the framing to allow the mounting brackets to be flush with the framing. (Figure 7)

  5. Connect the unit to the water supply, following the instructions in the section Water Supply Connection (page 13).

  6. Locate the connector plate in the top right back corner of the unit. Remove the connector plate by removing the 2 securing screws. (Figure 8)

  7. Install a cable connector (not included), suitable for installing in a 7 /8″ (22 mm) hole, to the plate and feed the supply cable through the cable connector.

  8. Complete the wiring according to instructions in the Electrical Installation section (pages 14–15). Reinstall the connector plate after completing wiring.

  9. Finish surrounding wall up to the trim if a permanent installation is desired. A removable trim can be used instead to cover the framing opening to allow the fireplace to be removed without damaging the finished wall.
    CAUTION: Ensure air inlets are present in final installation (see Fresh Air Inlets, page 10).
    ! NOTE: It is recommended that all drywall installation and finishing be completed after unit is fully installed, inspected, and operational.

  10. Finish the installation using the finishing materials of your choice.

  11. Place the media as desired and install the front glass.
    Installation Instructions

Water Supply Connection

CAUTION: Ensure that all plumbing connections meet local plumbing code requirements. Ensure that the location of the plumbing connection allows for easy access to allow for shutoff during scheduled maintenance.

Water Quality
Normal tap water can be used in the Opti-myst®. In areas with hard water, a water softener is recommended and more frequent cleaning and maintenance may be required. Unfiltered water supplied from a well or another unmonitored supply is not recommended. The product is provided with an in-line mesh filter to help remove contaminants and extend the life of the product.

Plumbing Instructions
The units are designed to be hard plumbed by connecting to a water source using standard 1/4″ (6.4 mm) O.D. tubing. A plumbing accessory kit CDFIPLUMB- KIT, designed for use with copper piping, is available from your Dimplex dealer.

  1. Prepare a cold-water line in the vicinity of the desired installation location of the fireplace. Ensure that the location of the plumbing connection allows for easy access to allow for shutoff during scheduled maintenance.
    ! NOTE: Once the new plumbing connections are complete ensure that the lines are flushed to prevent any debris from going into the unit.

  2. Lift the media tray out of the unit and set it aside.

  3. Connect the water line, reduced to 1/4″ tubing, to the main valve located in the bottom left side of the unit. (Figure 6)
    CAUTION: Ensure that the end of the tubing is cut square to prevent leaking.

  4. Connect the water supply tubing to the main water valve by removing the locking ring and inserting the tubing so that it is fully inserted (approximately 1/2″ [12 mm]). Reinstall the locking ring.

  5. Complete electrical installation steps before opening the main water valve.

  6. Priming (pre-filling with water) is required. See Priming the Unit on page 22.
    Plumbing Instructions

Refillable Water Containers

! NOTE: Not recommended for applications with frequent use.
If direct connection to a water supply is not possible, the reservoir can be manually filled using an Opti-Myst refillable container (9601350100RP) (not provided) which can be purchased at www.dimplex.com/replacement_parts. One container will be needed for each flame module in the fireplace. One refill will provide up to 6 hours of flame operation. The front glass and media tray will need to be removed each time the containers need to be refilled.

Electrical Installation

CAUTION: A dedicated, properly fused 15 Amp circuit is recommended, rated for the appropriate voltage (120 V, 240 V). A dedicated circuit will be required if, after installation, the circuit breaker trips or fuse blows on a regular basis when the heater is operating. Additional appliances on the same circuit may exceed the current rating of the circuit breaker.

120 V Hardwire Installation

! NOTE: For OLF86-AM, when connected to 120 V, there will be no heat output, but heat functions will be active on the controls with only fans operating.

  1. Connect the black L1 wire from the unit to the live wire from the power supply with a wire connector.
  2. Connect the white N wire from the unit to the neutral wire from the power supply with a wire connector.
  3. Connect the green G wire from the unit to the ground wire from the power supply with a wire connector or attach the grounding wire to the cover with the provided grounding screw, by placing the wire in between screw and lock washer and tighten.
  4. Ensure all wire connections are tight.
    Hardwire Installation

240 V Hardwire Installation

You will need a 4-wire 240 V supply (L1, L2, Neutral, and Ground).

  1. Connect the black L1 wire from the unit to the L1 wire from the power supply with a wire connector.
  2. Connect the red L2 wire from the unit to the L2 wire from the power supply with a wire connector.
  3. Connect the white N wire from the unit to the neutral wire from the power supply.
  4. Connect the green G wire from the unit to the ground wire from the power supply with a wire connector or attach the grounding wire.
  5. Ensure all wire connections are tight.
    Hardwire Installation

Optional Plug Kit (OLFPLUG, sold separately)

WARNING: Power cord option is only suitable for 120 V installations.

  1. Remove the 3 screws that hold the connector plate.
  2. Connect the black L1 wire from the unit to the black wire of the plug kit.
  3. Connect the white N wire from the fireplace to the white wire from the plug kit.
  4. Connect green G wire from the fireplace to the green wire from the plug kit.
  5. Ensure all wire connections are tight.
  6. Secure the power cord’s pre-installed cover plate using the screws removed when removing the connector plate. The previously removed connector plate can be disposed of.

WARNING: This heater is not intended for use with an extension cord. Plug the cord directly into an ap propriate wall receptacle.
Optional Plug Kit

Heater Hardware Disconnect

The fireplace heater can be permanently disabled by removing the electronic jumper on the main control board. Heater hardware disconnect will permanently disable the heater and fan function. Follow these instructions ONLY when an installation without heat is required. Temporary disabling of the heater can be achieved through the hidden touch controls. See “Heat Disable” in Operation section (page 20) for instructions.
The recirculating fan and the element in the flame module will not be disabled.

To disconnect the heater and fan permanently:

  1. Remove the 4 screws that secure the right-side upper LED lights and disconnect the wire.
  2. Remove the 5 screws that secure the right-side upper panel. Carefully lower the upper panel, which is held by hinges to the housing.
  3. Locate the main control board. The heater hardware disconnect jumper location is labeled “J2”. (Figure 13)
  4. Remove the heater hardware disconnect jumper.
  5. Secure the upper panel back in its original position.
  6. Reconnect the wire for the upper LED lights, and secure in place.
    Heater Hardware Disconnect
Flame Baffles

Flame Baffles
Flame Baffles
Flame Baffles

The unit comes with breakable and slotted baffles to create a customized flame. The unit can be operated with or without the baffles. The baffles will create spacing to customize a unique flame appearance. Separate the breakable baffles by bending the strip until it breaks into 4 single baffles. (Figure 15) The slotted baffles are not breakable.
To insert the baffles, use a screwdriver to carefully pry open the flame output slot on the top cover. (Figure 14) Install the baffle by putting the side with the two tabs down, and inserting it so that the lip on the top cover goes over the baffle. (Figure 16)
Place the breakable baffles across the flame output slot as desired to create the desired flame appearance. Three slotted baffles are required to cover each flame output slot.

Warranty

OPTI-MYST LINEAR™ 2-YEAR LIMITED WARRANTY
Section 1 Products to which this Limited Warranty Applies

This Limited Warranty applies to your newly purchased Dimplex electric fireplace with model numbers OLF46-AM, OLF66-AM, and OLF86-AM.

This Limited Warranty applies only to purchases made in any province of Canada except for Yukon Territory, Nunavut, or Northwest Territories or in any of the 50 States of the USA and the District of Columbia except for Hawaii and Alaska. This Limited Warranty applies to the original purchaser of the product only and is not transferable.

Section 2 Products excluded from this Limited Warranty
Products purchased in Yukon Territory, Nunavut, Northwest Territories, Hawaii, or Alaska are not covered by this Limited Warranty. Products purchased in these States, Provinces, or Territories are sold AS IS without Warranty or condition of any kind including, without limitation, any implied warranties or conditions of merchantability or fitness for a particular purpose. The entire risk of as to the quality and performance of the products is with the purchaser. In the event of a defect, the purchaser assumes the entire cost of all necessary servicing or repair.

Section 3 What this Limited Warranty covers and for How Long
Opti-Myst Linear™ products OLF46-AM, OLF66-AM, and OLF86-AM excluding trims and accessory packages are covered by this Limited Warranty, have been tested and inspected prior to shipment and, subject to the provisions of this Warranty, Glen Dimplex Americas Ltd. (herein called Glen Dimplex Americas) warrants such products to be free from defects in material and workmanship for a period of 5 years from the date of the first purchase of such products. The 5-year Limited Warranty entitles the purchaser to On-site or In-home Warranty Services. Accordingly, Glen Dimplex Americas will be responsible for all labor and transportation associated with repairing or replacing the product or part. Exceptions to this are outlined in Section 5. Some jurisdictions do not allow limitations on how long an implied Warranty lasts, so the above limitation may not apply to the purchaser.

Section 4 What this Limited Warranty Does Not Cover
This Limited Warranty does not apply to products that have been repaired (except by Glen Dimplex Americas or its authorized service representatives) or otherwise altered. This Limited Warranty does further not apply to defects resulting from misuse, abuse, accident, neglect, incorrect installation, improper maintenance or handling, or operation with an incorrect power source.

Section 5 How to notify us of a Warranty Concern Defects must be brought to the attention of Dimplex Customer Service online at dimplex.com/en/contact_us or by telephone at 1-888-346-7539. Please have proof of purchase, catalogue/model and serial numbers available for representatives to assist. **Limited In-home Warranty Services require proof of purchase. In the event a product or part covered by this Limited

Warranty is proven to be defective in material or workmanship during (i) the 2-year Limited Warranty period for products outlined in Section 1, you have the following rights:

Documents / Resources

| Dimplex OLF46-AM Opti Myst Linear Electric Fireplace with Acrylic Ice and Driftwood [pdf] User Guide
OLF46-AM, OLF66-AM, OLF86-AM, OLF46-AM Opti Myst Linear Electric Fireplace with Acrylic Ice and Driftwood, Opti Myst Linear Electric Fireplace with Acrylic Ice and Driftwood, Electric Fireplace with Acrylic Ice and Driftwood, Acrylic Ice and Driftwood, Ice and Driftwood, Driftwood
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals