Deye M60-100G3 Micro Inverter User Manual
- June 13, 2024
- Deye
Table of Contents
M60-100G3 Micro Inverter
Product Information:
The Micro Inverter is an integrated NS protection device with
built-in WIFI-G. It is designed to maximize PV energy production
and is more reliable than centralized or string inverters. The
Micro Inverter is simple to install and comes with required parts
and tools.
Product Usage Instructions:
-
Before installing or using the Micro Inverter, read all
instructions and cautionary markings in the technical documents and
on the Micro Inverter system and the solar-array. -
Only qualified professionals should install and/or replace the
Microinverters. Perform all electrical installations in accordance
with local electrical codes. -
Do not disconnect the PV module from the Micro Inverter without
disconnecting the AC power. -
Be aware that the body of the Micro Inverter is the heat sink
and can reach a high temperature. Do not touch the body of the
Microinverter to reduce the risk of burns. -
Maintain a distance of at least [cm] from the Microinverter
when it is working properly. -
If the Micro Inverter fails, contact technical support for an
RMA number and start the replacement process. Do not attempt to
repair or open the Micro Inverter as it will void the
warranty. -
When connecting or disconnecting the Micro Inverter, follow the
provided instructions carefully. Ensure proper earthing connections
and install isolation switching devices on the AC side of the
inverter.
Safety Instructions:
WARNING: Failure to follow instructions may
cause serious hardware failure or personnel danger. Use extreme
caution when performing tasks.
NOTE: Information that is important for
optimized Micro Inverter operation. Follow these instructions
strictly.
Radio Interference Statement:
No information provided.
The Meaning of Symbols:
- Can be OEM Trademark.
- Caution, risk of electric shock.
- Caution, risk of burn – Do not touch.
- Caution, hot surface.
- Symbol for the marking of electrical and electronics devices
according to Directive //EC. Indicates that the device,
accessories, and packaging must be collected separately at the end
of usage and not disposed as unsorted municipal waste. Follow local
ordinances or regulations for disposal or contact an authorized
representative of the manufacturer for information concerning
equipment decommissioning.
Installation / User Manual
Micro Inverter (Integrated NS Protection Device) (Built-in WIFI-G)
7FS
Table of Contents
NQPSUBOU4BGFUZOTUSVDUJPOT
Safety Instructions Radio Interference Statement The Meaning of Symbols
.JDSPOWFSUFS4ZTUFNOUSPEVDUJPO
Microinverters Maximize PV Energy Production More Reliable than Centralized or
String Inverters Simple to Install
.JDSPOWFSUFSOUSPEVDUJPO .JDSPOWFSUFS4ZTUFNOTUBMMBUJPO
Required Parts and Tools from You Parts list Installation Procedures
.JDSPOWFSUFS4ZTUFN0QFSBUJOHOTUSVDUJPOT 5SPVCMFTIPPUJOH
Status Indications and Error Reporting Troubleshooting a Non-operating Micro
Inverter
3FQMBDFNFOU 5FDIOJDBM%BUB
M / / G Micro Inverter Datasheet
8JSJOH%JBHSBN .POJUPSJOH1MBUGPSN How to connect the SUN-MI-RELAY- to the Micro
Inverter via web )PXUPDPOOFDUUIF.JDSP*OWFSUFSUPUIFSPVUFSWJBXFC
)PXUPDPOOFDUJO”11 &6%FDMBSBUJPOPG$POGPSNJUZ
Important Safety Instructions
This manual contains important instructions to follow during installation and
maintenance of the Photovoltaic Grid-connected Inverter(Micro Inverter).To
reduce the risk of electrical shock and ensure the safe installation and
operation of the Micro Inverter the following symbols appear throughout this
document to indicate dangerous conditions and important safety instructions.
Specifications subject to change without notice – please ensure you are using
the latest manual found at the manufacturer website.
WARNING: This indicates a situation where failure to follow instructions may
cause a
serious hardware failure or personnel danger if not applied appropriately. Use
extreme caution when performing this task.
NOTE: This indicates information that is important for optimized Micro
Inverter
operation. Follow these instructions strictly.
Safety Instructions
DO NOT disconnect the PV module from the Micro Inverter without disconnecting
the AC power.
Only qualified professionals should install and/or replace the Microinverters.
Perform all electrical installations in accordance with local electrical
codes.
Before installing or using the Micro Inverter, please read all instructions
and cautionary markings in the technical documents and on the Micro Inverter
system and the solar-array.
Be aware that the body of the Micro Inverter is the heat sink and can reach a
temperature of . To reduce risk of burns,do not touch the body of the
Microinverter.
When the microinverter is working properly, please maintain a distance of at
least cm from it.
DO NOT attempt to repair the Micro Inverter. If it fails, contact technical
support
to obtain an RMA number and start the replacement process. Damaging or opening
the Micro Inverter will void the warranty.
Caution! The external protective earthing conductor is connected to the
inverter protective earthing terminal through AC connector. When connecting,
connect the AC connector first to ensure the inverter earthing then do the DC
connections. When disconnecting, disconnect the AC by opening the branch
circuit breaker first
– –
but maintain the protective earthing conductor in the branch circuit breaker
connect to the inverter ,then disconnect the DC inputs. In any circumstance,
do not connect DC input when AC connector is unplugged. Please install
isolation switching devices on the AC side of the inverter.
Radio Interference Statement
The equipment could radiate radio frequency energy and this might cause
harmful interference to radio communications if not following the instructions
when installing and using the equipment. But there is no guarantee that
interference will not occur in a particular installation. If this equipment
causes harmful interference to radio or television reception,the following
measures might resolve the issues: A) Relocate the receiving antenna and keep
it well away from the equipment. B) Consult the dealer or an experienced radio
/ TV technical for help. Changes or modifications not expressly approved by
the party responsible for compliance may void the user’s authority to operate
the equipment. WiFi information Frequency range.~.GHz WiFi maximum
transmitting powerdBm ± dBm AntennaExternal Antenna Antenna Gain.dBi
– –
The Meaning of Symbols
Can be OEM Trademark.
Caution, risk of electric shock.
Caution, risk of burn – Do not touch.
Caution, hot surface.
Symbol for the marking of electrical and electronics devices according to
Directive //EC. Indicates that the device, accessories and the packaging must
not be disposed as unsorted municipal waste and must be collected separately
at the end of the usage. Please follow Local Ordinances or Regulations for
disposal or contact an authorized representative of the manufacturer for
information concerning the decommissioning of equipment.
CE mark is attached to the solar inverter to verify that the unit follows the
provisions of the European RED Directives.
Refer to the operating instructions.
Qualified personnel
Person adequately advised or supervised by an electrically skilled person to enable him or her to perceive risks and to avoid hazards which electricity can create. For the purpose of the safety information of this manual, a “qualified person” is someone who is familiar with requirements for safety, refrigeration system and EMC and is authorized to energize,ground, and tag equipment, systems, and circuits in accordance with established safety procedures. The inverter and endues system may only be commissioned and operated by qualified personnel.
Micro Inverter System Introduction
The Micro Inverter is used in utility-interactive grid-tied applications,
comprised of three key elements: · Micro Inverter · SUN-MI-RELAY-Network and
System Protection Device · Router This series Micro Inverter has built-in WIFI
module so it can communicate with router directly.
– –
M / / G
SUN-MI-RELAY-Network and System Protection Device: it is used to monitoring and
disconnect the grid when sensing the grid voltage/frequeny is out of the allowed range. The
relay kit also is able to reconnect grid when the grid condtions resume. It must communi-
cate with the built-in wifi module of the Micro Inverter, the Micro Inverter can work
normally, otherwise the Micro Inverter can not work. The localhost of this relay kit is
….
.
INVERTER
GRID
INVERTER
INVERTER
GRID GRID
SUN-MI-RELAY-
3PVUFS
.POJUPSJOHTZTUFN
a.
b.
– –
NOTE: For the connection between SUN-MI-Relay-( Network and System Protection Dev -ice) and Micro Inverter, the tool(screwdriver) is needed.
WARNING: The Micro Inverter SUN-MG-EU-Q, SUN-MG-EU-Q, SUN-
MG-EU-Q shall not be put into operation without external relay kit SUN-MI-
RELAY-.
Name
Functions
COM
The COM light indicates the communication status of the microinverter and
relay.
COM light flashes blue, Successfully communicated
AC/M blue light flashes twice, Interconnection AC/M working status (relay is closed)
Press and hold for seconds, The relay resets, disconnects, and automatically
closes after two minutes.
SET Press and hold for seconds, The communication between the relay and the
microinverter was disconnected, and communication resumed after two minutes.
17 .PEVMF
17 17 .PEVMF .PEVMF
17 17 .PEVMF .PEVMF
17 .PEVMF
.FUFS
.JDSP*OWFSUFS
SUN-MI -RELAY-
.JDSP*OWFSUFS
SUN-MI -RELAY-
.JDSP*OWFSUFS
+VODUJPO#PY
SUN-MI
-RELAY-
WIFI Boost Router
Monitoring system
/FVUSBM (SPVOE
%JTUSJCVUJPO#PY
Inverter Model
SUN-MG-EU-Q
PV Input Voltage
PV Array MPPT Voltage Range No. of MPP Trackers
No. of Strings per MPP Tracker
SUN-MG-EU-Q
.V (V~V) V~V
SUN-MG-EU-Q
NOTE: If the wireless signal in the area where the Micro Inverter is installed is weak, it is
necessary to add a wifi signal booster at a suitable place between the router
and the Micro Inverter.
– –
This integrated system improves safety; maximizes solar energy
harvest;increases system reliability, and simplifies solar system design,
installation,maintenance, and management.
Microinverters Maximize PV Energy Production
Each PV module has individual Maximum Peak Power Tracking (MPPT) controls,
which ensures that the maximum power is exported to the utility grid
regardless of the performance of the other PV modules in the array.When PV
modules in the array are affected by shade, dust, orientation,or any situation
in which one module underperforms compared with the other units, the Micro
Inverter ensures top performance from the array by maximizing the performance
of each module within the array.
More Reliable than Centralized or String Inverters
The distributed Micro Inverter system ensures that no single point of system
failure exists across the PV system.Microinverters are designed to operate at
full power at ambient outdoor temperatures of up to (). The inverter housing
is designed for outdoor installation and complies with the IP environmental
enclosure rating.
Simple to Install
You can install individual PV modules in any combination of Module quantity,
orientation, different type and power rate. The Ground wire (PE) of the AC
cable is connected to the chassis inside of the Micro Inverter,potentially
eliminating the installation of grounding wire (check local regulation). Data
collection adopts internal wifi,wireless router is needed near the Micro
Inverter. When complete the installation of Micro Inverter,configure wireless
router with internal wifi(refer to the wifi user manual).The data will be
uploaded automatically.Users can monitor and manage the Micro Inverter through
corresponding website or APP.
Micro Inverter Introduction
The Microinverters connect with the single-phase grid, and can also use
multiple Microinverters in the form of single-phase grid to achieve three-
phase grid. For more information, please see the Technical Data page (P) of
this manual.
– –
Model Number
SUN-MG-EU-Q
AC grid /Hz, V
SUN-MG-EU-Q /Hz, V
SUN-MG-EU-Q /Hz, V
Max. # Per branch for A breaker
for A breaker
for A breaker
Micro Inverter System Installation
A PV system using Microinverters is simple to install. Each Micro Inverter
easily mounts on the PV racking, directly beneath the PV module(s). Low
voltage DC wires connect from the PV module directly to the Micro Inverter,
eliminating the risk of high DC voltage.Installation MUST comply with local
regulations and technical rules.
WARNING: Perform all electrical installations in accordance with local
electrical codes.
WARNING: Be aware that only qualified professionals should install and/or
replace
Microinverters.
WARNING: Before installing or using an Micro Inverter,please read all
instructions and
warnings in the technical documents and on the Micro Inverter system itself as
well as on the PV array.
WARNING: Be aware that installation of this equipment includes the risk of
electric
shock.
NOTE: Strongly recommend to install Surge protection Devices in the dedicated
meter
box.
Required Parts and Tools from you
In addition to your PV array and its associated hardware, you will need the
following items: cAn or several AC connection junction boxes c Mounting
hardware suitable for module racking cSockets and wrenches for mounting
hardware cContinuous grounding conductor and grounding washers cA Phillips
screwdriver cA torque wrench
– –
Parts list
Please check the following table, to see whether all the parts are included in
the package
Micro Inverter x
User manual
User manual x
AC extension cable (optional) x N-
Bus AC connector (optional) x
T-connector (optional) x N-
Extension cable with European standard plug (optional) x
Clip x
SUN-MI-RELAY- (Network and System Protection Device) x
- Choose either Bus AC connector or Extension cable with European standard plug, can’t use them in the same project.
– –
Installation Procedures
Step – Install the AC branch circuit junction box
a. Install an appropriate junction box at a suitable location on the PV
racking system (typically at the end of a branch of modules).
b. Connect the open wire end of the AC cable into the junction box using an
appropriate gland or strain relief fitting.
c. Connect the AC branch circuit junction box to the point of utility Grid
Interconnection Usually it is inside a distribution box.
17 .PEVMF
17 17 .PEVMF .PEVMF
17 17 .PEVMF .PEVMF
17 .PEVMF
.JDSP*OWFSUFS
SUN-MI -RELAY-
.JDSP*OWFSUFS
SUN-MI -RELAY-
.JDSP*OWFSUFS
Junction box
SUN-MI -RELAY-
.FUFS
/FVUSBM (SPVOE %JTUSJCVUJPO#PY
WARNING: Wiring colour code can be different according local regulation,check
all
the wires of the installation before connecting to the AC cable to be sure
they match. Wrong cabling can damage irreparably the microinverters,such an
issue is not covered by the warranty.
– –
Step – Attach the Microinverters to the racking or the PV module frame a. Mark
the location of the Micro Inverter on the rack, with respect to the PV module
and junction box or any other obstructions. b. Mount one Micro Inverter at
each of these locations using hardware recommended
by your module racking vendor.
mm²(AWG)
M / / G (MPPT) Mounting The AC wire on the micro inverter is a TC-ER wire with
a wire cross-section area of mm²(AWG).
WARNING:Prior to installing any of the microinverters, verify that the utility
voltage
at the point of common connection matches the voltage rating on Micro Inverter
label.
WARNING: Do not place the inverters (including DC and AC connectors) where
exposed to the sun, rain or snow, even gap between modules.Allow a minimum of
/ (.cm.) between the roof and the bottom of the Micro Inverter to allow proper
air flow.
– –
Step 3 – Connect the microinverters in parallel
a. Check the Micro Inverter technical data page for the maximum allowable
number of Microinverters on each AC branch circuit.
b. As to parallel connection, please refer to page (P-P), use the T-connector,
AC extension cable, Bus AC connector(If only one branch, just use the
Extension cable with European standard plug) to connect the Micro Inverter in
each branch.
1&
.PEFM 46/.(&62 46/.(&62 46/.(&62
–
/
Male connector
8JSF4J[F
“8( “8( “8(
$BCMF NN
5PSRVFWBMVF NBY
/N /N /N
.BYDBCMFMFOHUI
0VUTJEFDBCMF -/1&
N
WARNING: DO NOT exceed maximum number of Microinverters in an AC branch
circuit, as displayed on the page of this manual.
T-connector
NOTE: Port marked with two-way arrow on T-type plug can only connect with
extended
cable and Port marked with one-way arrow on T-type plug can only connect with
Micro Inverter.
– –
Step 4 – Connect the wire open of branch end to the junction box.
INVERTER
+VODUJPO#PY
GRID
Step 5 – Connect Micro Inverter to the PV Modules
General Guidelines: a. PV modules should be connected to DC input ports of a
Micro Inverter. b. In order to meet the relevant regulatory requirements, the
cable length must be <M. Please consult the local power operator to make sure
that the DC cable complies with local regulations.
NOTE:When plugging in the DC cables, if AC already available,the Micro
Inverter should
immediately blink red light and will start work within the setting time
(default seconds). If AC is not available,the red light will blink times
quickly and repeat after one second until AC is connected.
Micro Inverter System Operating Instructions
To operate the Micro Inverter PV system:
. Turn ON the AC circuit breaker on each Micro Inverter AC branch circuit.
. Turn ON the main utility-grid AC circuit breaker. Your system will start
producing power after a one-minute waiting time. – –
. The units should start blinking red one minutes after turning on the AC circuit breaker. Then blue led blinking. This means they are producing power normally, the faster blinking of the blue led means more power generated.
. Configure the internal wifi module according to its user manual.
. The Microinverters will start to send performance data over wifi module to
the network every minutes.It enables customers to monitor performance data of
each Micro Inverter through website and APP.
When AC power is applied but the Micro Inverter not started up, about .A
current and VA power for each Micro Inverter may be measured by a power meter.
This power is reactive power,not consume from utility grid.
Troubleshooting
Qualified personnel can use the following troubleshooting steps if the PV system does not operate correctly:
Status Indications and Error Reporting
Start up LED
One minute after DC power is first applied to the Micro Inverter,one short red blinks indicate a successful Micro Inverter startup sequence, be equal or greater than two short red blinks after DC power is first applied to the Micro Inverter indicate a failure during Micro Inverter setup.
Operation LED
Flashing Slow Blue
– Producing small power
Flashing Fast Blue
– Producing big power
Flashing Red
– Not producing power
Red blinking two times – AC low-voltage or high-voltage
Red blinking three times – Grid failure
– –
GFDI Error A four time red LED indicates the Micro Inverter has detected a
Ground Fault Detector Interrupter (GFDI) error in the PV system. Unless the
GFDI error has been cleared, the LED will remain four times blinking.
Other Faults All other faults can be reported to the website and APP.
WARNING: Never disconnect the DC wire connectors under load. Ensure that no
current is flowing in the DC wires prior to disconnecting. An opaque covering
may be used to cover the module prior to disconnecting the module.
Troubleshooting a non-operating Micro Inverter
There are two possible overall areas of trouble: A. The Micro Inverter itself
may be having problems. B. The Micro Inverter itself is working fine but the
communication between Micro Inverter
and network has problem. The items below refer to Micro Inverter issues, not
communicat -ion issues:
One quick way to tell whether the issue is the Micro Inverter or the
communication problem: Diagnosing from the network:
a. No-Data-Display: The website and APP don’t display any data.Check the
network configuration.
b. Only display Micro Inverter is online but no data.This maybe because server
is updating.
– –
To troubleshoot a non-operating Micro Inverter, Follow the steps below in
order:
. Verify the utility voltage and frequency are within ranges shown in the
Technical Data section of this manual.
. Check the connection to the utility grid.Disconnect AC firstly,then
disconnect DC and make sure the utility grid voltage can be measured at AC
connector. Never disconnect the DC wires while the Micro Inverter is producing
power. Re-connect the DC module connectors and watch for three short LED
flashes.
. Check the AC branch circuit interconnection between all the microinverters.
Verify each inverter is energized by the utility grid as described in the
previous step.
. Make sure that any AC breaker are functioning properly and are closed. .
Check the DC connections between the Micro Inverter and the PV module. .
Verify the PV module DC voltage is within the allowable range shown in the
Technical
Data of this manual. . If the problem still persists, please contact technical
support.
WARNING: Do not attempt to repair the Micro Inverter.If troubleshooting
methods fail,
please call for Technical Support
– –
Replacement Follow the procedure to replace a failed Micro Inverter
A. Disconnect the Micro Inverter from the PV Module, in the order shown below:
. Disconnect the AC by turning off the branch circuit breaker. . Disconnect
the AC connector of the Micro Inverter. . Cover the module with an opaque
cover. . Disconnect the PV module DC wire connectors from the Micro Inverter.
. Remove the Micro Inverter from the PV array racking.
B. Install a replaced Micro Inverter to the bracket then remove the opaque
cover. Remember to observe the flashing LED light as soon as the new Micro
Inverter is plugged into the DC cables.
C. Connect the AC cable of the replacement Micro Inverter.
Technical Data
WARNING: Be sure to verify the voltage and current specifications of your PV
module
match with those of the Micro Inverter. Please refer to the datasheet or user
manual.
WARNING: You must match the DC operating voltage range of the PV module with
the allowable input voltage range of the Micro Inverter.
WARNING: The maximum open circuit voltage of the PV module must not exceed
the specified maximum input voltage of the inverter.
– –
MG/G/G Microinverter Datasheet
Model
Input Data (DC)
Recommended input power(STC) Maximum input DC voltage MPPT Voltage Range MPPT
Full Power Voltage Range(V) Min.DC input voltage(V) Max DC short circuit
current Max input current
Output Data (AC)
Rated output Power Max.AC Output Apparent Power
3BUFE”$PVUQVUDVSSFOU
Max.AC Output Current Nominal voltage / range Nominal frequency Extended
frequency / range Power factor Maximum unit per branch Max. allowed altitude
operating Max.inverter backfeed current to the array Max output fault current
Efficiency
CEC weighted efficiency Peak inverter efficiency Static MPPT efficiency Night
time power consumption
Mechanical Data
Ambient temperature range Dimensions(W×H×D mm) Weight (kg) Cooling Enclosure
environmental rating Protective class Topology
Features
Compatibility Communication Compliance Warranty
SUN-MG -EU-Q
SUN-MG -EU-Q
SUN-MG -EU-Q
8 1JFDF
8 1JFDF
8 1JFDF
7
_7
77
77
77
7
“Y
“Y
8 7″
” ”
8 7″
” ” 76O6O )[
)[)[
N
”
”
8 7″
” ”
N8
¥_¥
¥EFSBUJOH 8)% 8JUIPVUNPVOUJOHCSBDLFUBOEDBCMF
/BUVSBMDPPMJOH
1 $MBTT *TPMBUFE)’5SBOTGPSNFS
$PNQBUJCMFXJUI
DFMM17NPEVMFT
8J’J &/
7%&
7%&
&$
$&
/.&530
:FBST
- Note : years warranty (only installed in Germany and Austria)
– –
Technical Data
Model:SUN-MI-RELAY- AC Intput Data(Inverter) Nominal Voltage Nominal Frequency
Max AC Current Nominal AC Current Matching Inverter AC Output Data(Grid)
Nominal Voltage Nominal Frequency Max AC Current Nominal AC Current General
Data Ambient Temperature Range Humidity
Cabinet Size (WxHxD)
Weight Enclosure Environmental Rating Communication
Safety EMC / Standard
WiFi information: Frequency range WiFi maximum transmitting power Antenna
Antenna Gain
Network and System Protection Device
V/V /Hz A A Micro Inverter
V/V /Hz A A
–, > derating %-% RH mmmm.mm (Excluding Connectors and Brackets) g IP
Wireless/Wifi IEC/EN–/, IEC/EN -, IEC/EN -,VDE-AR-N
.~.GHz dBm ± .dBm External Antenna dBi
– –
GRID GRID
GRID
Wiring Diagram
Sample Wiring Diagram Three Phase
– –
MG/G/G (MPPT)
RED L
BLACK N
YELLOW PE
JUNCTION
INVERTER
INVERTER
INVERTER
GRID
BOX
GRID
meter
INVERTER
INVERTER
INVERTER
GRID
GRID
INVERTER
INVERTER
INVERTER
GRID
GRID
WIFI Boost
GROUND Router
Monitoring system
MAX SUN-MG-EU-Q per Branch MAX SUN-MG-EU-Q per Branch MAX SUN-MG-EU-Q per Branch
GRID GRID
GRID
Sample Wiring Diagram Single Phase – –
MG/G/G (MPPT)
RED L
BLACK N
YELLOW PE
JUNCTION
BOX
GRID
GRID
INVERTER
INVERTER
INVERTER
meter
INVERTER
INVERTER
INVERTER
GRID
GRID
INVERTER
INVERTER
INVERTER
GRID
GRID
WIFI Boost
MAX SUN-MG-EU-Q per Branch MAX SUN-MG-EU-Q per Branch MAX SUN-MG-EU-Q per Branch
GROUND Router
Monitoring system
Monitoring Platform
This series Micro Inverter has built-in WIFI modular which is able to connect router
directly. For WIFI configuration, please check the manual o”f Built-in WIFI modular
Micro Inverter
WIFI configuration Manualp
Web monitoring address:https:////pprroo..ssoollaarrmmaannppvv..ccoomm;;(for Solarman distributor account) hhttttppss::////hhoommee..ssoollaarrmmanpv.com(for Solarman end user account)
For mobile phone monitoring system, scan the QR code to download the APP.
Also you can find it by searching”solarman business”in App store or Google Play store,
and this App is for distributor/installer.
Find it by searching”solarman smart”in App store or Google Play store and choose
“solarman smart”, this app is for plant owner.
SOLARMAN Smart for end user
SOLARMAN Business for distributor/installer
– –
How to connect the SUN-MI-RELAY- to the Micro Inverterr via web
. Turn on the wireless network of your PC or smartphone. . Select network of
SUN-MI-RELAY- (network name: RE_) and the default password of the network is
listed on the nameplate of PWD”: cdbd”.
You can also access this Wi-Fi network by sharing the password from a nearby iPhone, iPad, or Mac which has connected to this network and has you in their contacts.
Password:
Show Password
Cancel
Join
. Open a browser and enter …. Both username and password are “admin”. (Recommended browser: IE +, Chrome +, Firefox + ).
Sign in to …
Sign in to …
Your password wil be sent unencrvpted.
admin
Remember this password.
Cancel
Sign in
If can’t access the … for a long while, please disconnect the AC and then
waiting for S and try again.
– –
. Browser jumps to” Status “page, the basic information is listed there.
Status Wizard Quick Set Advanced Upgrade Restart Reset
Inverter information
Inverter serial number Firmware version(main) Firmware version(slave) Inverter
model Rated power Current power Yield today Current power Alerts Last updated
Device information
Remote server information
W W kWh kWh
English
Help
The device can be used as a wireless access point(AP mode) to facilitata users
to configure the device, or it can also be used as a wireless information
terminal (STA mode) to connect the remote server via wireless router.
Status of remote server Not connected: Connection to server failed last time.
If under such status, please check the issues as follows: ()check the device
information to see whether IP address is obtained or not; ()check if the
router is connected to internet or not; ()check if a firewall is set on the
router or not;
Web Ver:1.0.24
. Click to enter the “Quick Set” page and click the “Search” button to start searching for network hotspots near the NS protection device.
Status Wizard Quick Set Advanced Upgrade Restart Reset
Network name (SSID) (Notecase sensitive)
Search
Encryption method
WPAPSK
Encryption algorithm
AES
Password (- bytes) (Note: case sensitive)
Obtain an IP address automatically Enable
IP address Subnet mask Gateway address DNS server address
… … …
Note: After clicking Save, the system will restart immediately.
Save
Help
In this page, you can click the “Search” button to automatically search for
nearby wireless access point, and connect your device to it by setting the
network parameters.
Note: If you haven’t set this kind of device before please follow the setup
wizard.
Note: After clicking Save, tho system will restart immediately.
You need to re-login the configuration interface after restart.
– –
. Click to select your micro-inverter’s WLAN hotspot and enter the inverter hotspot password.
Status Wizard Quick Set Advanced Upgrade Restart Reset
Please select your current wireless network:
Site Survey SSID AP_
BSSID EC:FD:F:A::A
RSSI Channel
Please enter the password!
English
Help
Please refresh repeatedly if there is no desirable wireless access point
available
Note: When RSSI of connection may be
tuhnestsaeblelec,tepdleWasiFeisneeletwctoortkhiesrloawvaeirlatbhlaennetw%o, rtkhceolorse
shorten the distance between the device and router.
OK
Refresh
. The default password of the AP network is if there’s no nameplate that includes PWDXXXXXXXX on the inverter body. If there’s nameplate that includes PWDXXXXXXXX on the inverter body then the AP network password is the”XXXXXXXX”.
Status Wizard Quick Set Advanced Upgrade Restart Reset
Network name (SSID) (Notecase sensitive)
AP_
Search
Encryption method
WPAPSK
Encryption algorithm
AES
Password (- bytes) (Note: case sensitive)
Obtain an IP address automatically Enable
IP address Subnet mask Gateway address DNS server address
… … … …
Note: After clicking Save, the system will restart immediately.
Save
Help
In this page, you can click the “Search” button to automatically search for
nearby wireless access point, and connect your device to it by setting the
network parameters.
Note: If you haven’t set this kind of device before please follow the setup
wizard.
Note: After clicking Save, tho system will restart immediately.
You need to re-login the configuration interface after restart.
– –
Status Wizard Quick Set Advanced Upgrade Restart Reset
Setting completel Please close tis page manually!
Please login our management ponal to monitor and manage your PV system.(Please
register an account if you do not have one.) To re-login the configuration
interface, please make sure that your computer or srnart phone and our device
are in the same network sqy ent, and enter the new IP address of the dovice to
access the interface.
English
Help
Note: The IP address of the device may have changed, please refer to User
Manual to check the procedures to obtain the new IP address.
Web Ver:1.0.24
. Click to enter the Status page,You can view the current connection
information on the Device information page.if you need helpPlease contact
Deye’s official after-sales service or authorized service provider.
Status Wizard Quick Set Advanced Upgrade Restart Reset
Inverter information Inverter serial number
Firmware version(main)
Firmware version(slave)
Inverter model
Rated power
W
Current power
W
Yield today Current power
kWh kWh
Alerts
Last updated
Device information Device serial number Firmware version Wireless AP mode
SSID IP address MAC address Wireless STA mode Router SSID Signal Quality IP
address MAC address
LSWBLE_MW_RELAY.
-D Enable RE …
:A:F:B::F Enable
AP %
… :A:F:B::F
Remote server information Remote server A
Remote server B
Not connected Not connected
English
Help
The device can be used as a wireless access point(AP mode) to facilitata users
to configure the device, or it can also be used as a wireless information
terminal (STA mode) to connect the remote server via wireless router.
Status of remote server Not connected: Connection to server failed last time.
If under such status, please check the issues as follows: ()check the device
information to see whether IP address is obtained or not; ()check if the
router is connected to internet or not; ()check if a firewall is set on the
router or not;
Connected: connection to server successful last time;
Unknown: No connection to server.Please check again in minutes.
– –
How to connect the Micro Inverter to the router via web
. Turn on the wireless network of your PC or smartphone. . The default
password of the AP network is if there’s no nameplate that includes
PWDXXXXXXXX on the inverter body. If there’s nameplate that includes
PWDXXXXXXXX on the inverter body then the AP network password is the”XXXXX
XXX”: for example, the default password of AP network is”cdbd”of the inverter
SN:.
AP_ 4BGF
4BGF 4BGF
Micro Inverter SN
4BGF Micro Inverter SN: Built-in datalogger :
Also, the default password can be changed. If forgetting the modified
password, please contact service@deye.com.cn for help.
. Open a browser and enter …. Both username and password are “admin”.
(Recommended browser: IE +, Chrome +, Firefox + ).
…
Status Wizard Quick Set Advanced Upgrade Restart Reset
http://… Please input username and password”. USER LOGIN”
Username: admin Password:
Sure
Cancel
Help
The setup wizard will assist you to complete the device setting within one
minute.
. Browser jumps to” Status “page, the basic information is listed there.
– –
Status Wizard Quick Set Advanced Upgrade Restart Reset
Inverter information Inverter serial number Firmware version(main) Firmware
version(slave) Inverter model Rated power Current power Yield today Current
power Alerts Last updated
Device information Device serial number Firmware version Wireless AP mode
SSID IP address MAC address Wireless STA mode Router SSID Signal Quality IP
address MAC address
Remote server information Remote server A Remote server B
W W kWh kWh
LSW_FFFF..
Enable AP_
… C:D:B::D:B
Disable
Help
The device can be used as a wireless access point(AP mode) to facilitata users
to configure the device, or it can also be used as a wireless information
terminal (STA mode) to connect the remote server via wireless router.
Status of remote server Not connected: Connection to server failed last time.
If under such status, please check the issues as follows: ()check the device
information to see whether IP address is obtained or not; ()check if the
router is connected to internet or not; ()check if a firewall is set on the
router or not;
Connected: connection to server successful last time;
Unknown: No connection to server.Please check again in minutes.
Not connected Not connected
. Turn to “Wizard” page, click “Refresh” to search the wireless network. Select the target network and click “Next” .
Status Wizard Quick Set Advanced Upgrade Restart Reset
Please select your current wireless network:
IE-.G-TEST
:A::::
AP_ IGENoffice.G IGENTEST
IGENoffice.G
AP_ IGENoffice.G
:BE:D::B:C :EA:E::B: :BE:D::B:C E::D:F::B :D:C::: :D:C::: :D:C::C:E :EA:E::CF:B :D:C::C:E
TESR+””= IGENoffice.G AP_
A:E:EC:E:C:E :BE:D::B:EE :D:::BA:
Note: When RSSI of the selected WiFi network is lower than %, the connection may be unstable, please select other available network or shorten the distance between the device and router.
Reeffresh
Add wireless network manually:
Network name (SSID) (Note:case sensitive)
Encryption method
IE-.G-TEST WPAPSK
Encryption algorithm AES
Next
1
2
3
4
Help
The setup wizard will assist you to complete the device setting within one
minute.
– –
. Enter the password and click Next.
Status Wizard Quick Set Advanced Upgrade Restart Reset
Please fill in the following information:
Password(- bytes) (Note: case sensitive)
Obtain an IP address automatically IP address Subnet mask
Gateway address DNS server address
Show Password Enable
Back
Next
Help
Most systems support the function of DHCP to obtain IP address automatically.
Please select disable and add it manually if your router does not support such
function.
. Users can select any options below to enhance the security and click Next.
Status Wizard Quick Set Advanced Upgrade Restart Reset
Enhance Security
You can enhance your system security by choosing the following methods Hide AP
Change the encryption mode for AP Change the user name and password for Web
server
Help
Change the encryption mode for AP If you set password for the AP network, you
will need to enter the password to connect to AP.
Change the user name and password for Web server If you change the username
and password for the web server, you will need to enter the new username and
password to get access to the setting page.
Back
Next
. If the setup is successful, the following page will pop up and click OK to
reboot the
micro inverter. – –
Status Wizard Quick Set Advanced Upgrade Restart Reset
Setting complete!
Click OK, the settings will take effect and the system will restart
immediately.
If you leave this interface without clicking OK, the settings will be
ineffective.
Help
After clicking OK,the system will restart immediately.
Back
OK
. Connect to loggeer AP network again, then log in to … by Browser, and check the system info of “Status” page. After the network setting is done, the remote server A or B should be “connected”.
Status Wizard Quick Set Advanced Upgrade Restart Reset
Inverter information Inverter serial number Firmware version(main) Firmware
version(slave) Inverter model Rated power Current power Yield today Current
power Alerts Last updated
Device information Device serial number Firmware version Wireless AP mode
SSID IP address MAC address Wireless STA mode Router SSID Signal Quality IP
address MAC address
Remote server information Remote server A Remote server B
W W —kWh —kWh
LSW_FFFF..
Disable
Enable IE-.G-TEST
% … :D:::D:B
connected Not connected
Help
The device can be used as a wireless access point(AP mode) to facilitata users
to configure the device, or it can also be used as a wireless information
terminal (STA mode) to connect the remote server via wireless router.
Status of remote server Not connected: Connection to server failed last time.
If under such status, please check the issues as follows: ()check the device
information to see whether IP address is obtained or not; ()check if the
router is connected to internet or not; ()check if a firewall is set on the
router or not;
Connected: connection to server successful last time;
Unknown: No connection to server. Please check again in minutes.
. When it shows “connected” which means this Micro Inverter has connected
solarman platform successfully. Generally speaking, it will be online after
-min after configuration successfully at the first time.
– –
How to connect in APP
. Registration Open the app of SOLARMAN Smart and register an account. Click
“Register” and create your account here.
English
SOLARMAN Smart
E-mail Phone Number Username E-mail E-mail Password password
Register
Phone Number
E-mail Please enter E-mail
Verification Code Please enter verification code Retrieve Xs
Register
Log In Forgot Password?
Password Password Password length must be greater than bits
. Create a Plant Click “Add Now” to create your plant. Please fill in plant basic info and other info here.
MY Plants
YOU have no plants for now.
Add Now
plant
Me
Basic Info Plant Name
Plant Details Demo plant -Commercial
Plant Loc
Zhwjiang yuyao
Time Zone
((UTC+:)Beijing,Chongqing, HongKong,Urumqi)
Creation Date
—
Founder SSyysstteemmIInnffoo Plant Type
Clavin Residential Rooftop
System Type
All on Grid
Installed Capacity(kWp)
Finish
– –
. Add a Logger
Optional : Enter the logger SN manually. Optional : Click the icon in the
right and scan the QR code to enter logger SN. You can find logger SN on the
carton packaging or on the logger body.
MY Plants
Create a Plant Add a device
Add a logger
Please enter the logger SN belongs to the olant.System will calulate plant
data according to the logger.
SN Please enter device SN Cannot Find SN/Barcode ?
Demo plant-Micro inverter shared
.W
Current Production Power
.MWh
Production-Today
.K CNY
Anticipated YieldToday
.K CNY
Anticipated Yield-This Month
Add
More
. Network Configuration After the logger is added, please configure the
network to ensure normal operation. Go to “Plant Details”-“Device List”, find
the target SN and click ” Device Networking”. If showing”online” which means
the datalogger of the inverter connects the solarman platform successfully.
Then you will be able to check the plant info on the platform.
Inverter Logger Meter
Device Details
NO. of Connections:
Logger
SN:
Normal
Select associated device Device Networking
Module
Logger
SN:
Offine Device Networking
– –
EU Declaration of Conformity
within the scope of the EU directives · Radio Equipment Directive //EU (RED) ·
Restriction of the use of certain hazardous substances //EU)(RoHS) NINGBO DEYE
INVERTER TECHNOLOGY CO.,LTD confirms herewith that the products described in
this document are in compliance with the fundamental requirements and other
relevant provisions of the above mentioned directives. The entire EU
Declaration of Conformity can be found at www.deyeinverter.com. Please scan
the QR code to download the certification.
– –
References
- マックスサーバ... CGI、PHP、ASP、フロントページ対応...安心と快適のウェブホスティング!
- Solar Grid-Tie Inverter Manufacturers, PV On-Grid Inverter | Deye
- home.solarmanpv.com
- pro.solarmanpv.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>