VELIT 4000P Gas Oline Diesel Air Heater User Manual
- September 7, 2024
- VELIT
Table of Contents
4000P Gas Oline Diesel Air Heater
“`html
Product Information
Specifications
-
Heat output (Btu/h): 14000
-
Fuel: Gasoline, Diesel
-
Rated Voltage (V): 12
-
Operating voltage (V): 11-16
-
Fuel consumption (G/ h): Gasoline – 0.05~0.13, Diesel –
0.05~0.12 -
Rated power (W): 20~46
-
Working temperature: Not specified
-
Rated elevation (ft): 17000
-
Weight (Lb): 10
-
Dimensions (inch): 14.65.55.9
Product Usage Instructions
Overview
The Velit 4000P air heater consists of various components
including a drive unit, heat exchanger, burner, control unit, glow
plug, and housing. The heating process is controlled automatically
by the control unit where fuel is pumped into the combustion
chamber and ignited to heat the air pulled in by the heating air
fan before being distributed into the cabin area.
Structure and Components
Heater Components: List of components including
fan, motor, support frame, burner, control unit, and more.
Housing Components: List of components such as
inlet cap, upper housing, lower housing, and outlet cap.
Installation
Accessory Diagram: Refer to the accessory
diagram for installation details.
Installation Steps:
-
The heater can be installed inside or outside the vehicle.
-
If installed outside, ensure the location is not exposed to
rain or road debris. -
Maintain appropriate clearance in front of the inlet and outlet
for proper airflow. -
Ensure the inlet and outlet are free of obstructions.
FAQ
Q: Can the Velit 4000P air heater be used with both gasoline
and diesel?
A: Yes, the heater is compatible with both gasoline and diesel
fuels.
Q: What is the weight of the Velit 4000P air heater?
A: The weight of the heater is 10 lbs.
“`
4Kw/14000BTU Gasoline/Diesel
Air Heater User Manual
VER 1.3
4Kw Air Fuel Heaters
Thank you for purchasing this VELIT 4000P Gasoline/Diesel air heater. For
safety and best performance, please read and follow the instructions
carefully. The electronic version of this document is available under the
product page at velitcamping.com.
WARNING Improper installation or repair of Velit 4000P air heater can cause
fire or leakage of deadly carbon monoxide leading to serious injury or death.
To install and repair Velit heating and cooling systems, you need to strictly
follow this user manual and use only genuine Velit parts. ALWAYS carefully
follow Velit installation and repair instructions and heed all WARNINGS. Velit
rejects any liability for problems and damage caused by improper installation
or service.
WARNING 1. The heater shall not be used in areas with flammable and
explosive gas and dust. 2. The heater is prohibited to be used in the garage
and other
enclosed spaces to prevent suffocation or exhaust poisoning. 3. When
installing heaters on special vehicles, relevant specific
rules shall be followed, and it is strictly prohibited to install heaters in
violation of industry rules.
4. Explosive and flammable materials such as gas tank, compress air tank,
clothing, wood, plastic, etc. are strictly prohibited near the hot air outlet
and the exhaust outlet.
Table of Contents
4Kw Air Fuel Heaters
I. Overview························································································· 1
II. Structure and Components···························································· 2
III. Installation···················································································· 4
IV. Operation···················································································· 14
V. Electrical Diagram········································································ 18
VI. Error Codes and Troubleshooting··············································· 19
VII. Care and Maintenance······························································· 20
4Kw Air Fuel Heaters
I. Overview
1.1 Product introduction
2
Velit 4000P air heater consists of a drive unit (combustion air fan,
3
heating air fan and drive motor), heat exchanger, burner with
combustion chamber, control unit, glow plug and housing. The ignition
and fuel supply are automatically controlled by the control unit. After
starting up, fuel will be pumped into the combustion chamber and
ignited by the glow plug. Meanwhile the heating air fan pulls the indoor
cold air into the heat exchange channel. The air will be heated up by the
heat exchanger and then pushed into the cabin area.
1.2 Technical Specifications
1.3
Heat output (Btu/h)
14000
Fuel
gasoline
diesel
Rated Voltage (V)
12
Operating voltage (V)
11-16
Fuel consumption (G/ h)
0.05~0.13
0.05~0.12
Rated power (W)
20~46
Working temperature
-30°F – 75°F
Rated elevation (ft)
17000
Weight (Lb)
10
Dimensions (inch)
14.65.55.9
1
4Kw Air Fuel Heaters
II. Structure and Components
2.1 Heater components
1. Heater fan 2. Motor 3 Support frame 4. Fuel line rubber plug 5. Motor
mount 6. Control unit 7. Control unit mounting screw 8. Compressor wheel 9.
Screw 10. Screw 11. Burner 12. Fuel inlet 13. Fuel line gasket 14. Glow plug
15. Combustion chamber flange seat 16. Combustion chamber 17. Screw 18. Motor
sealing gasket 19. Screw 20. Combustion chamber sealing gasket 21. Heat
exchanger 22. Heat exchanger rubber ring 23. Glow plug cap 24. Temperature
sensor.
2
4Kw Air Fuel Heaters 2.2 Housing components
1.Inlet cap 2. Upper housing 3. Lower housing 4. Outlet cap
3
4Kw Air Fuel Heaters
III. Installation
3.1 Accessory diagram
3.2 Installation 3.2.1.1 The heater can be installed inside or outside the
vehicle. When
the heater is installed outside the vehicle, the installation location must
not be exposed to rain and debris on the road. 3.2.1.2 Appropriate clearance
must be kept in front of the inlet and outlet, as shown in the following to
ensure proper air flow. The inlet and outlet must be free of obstruction.
4
4Kw Air Fuel Heaters
3.2.2 The unit CAN NOT be installed sideway, meaning that the fuel port (E)
must face the ground.
3.2.3 The genuine sealing gasket must be used for installation and the
mounting surface must be flat. Four M6 nuts for securing the unit need to be
tightened at 67Nm.
NOTICE When the heater is reinstalled, the sealing gasket must be replaced.
3.2.4 If the thickness of the installed panel is less than 1.5mm, an
additional reinforcing plate must be installed.
5
4Kw Air Fuel Heaters
3.2.4. When a hose is connected to the hot air outlet, the inner diameter of the hose shall not be less than 60mm, and the material must have a temperature rating higher than 130 °C.
3.2.5. The maximum pressure difference between the intake side and the outlet side of the heater shall not be greater than 0.15 KPa.
3.2.6. The hot air outlet shall not be directed towards the non-heatresistant surfaces.
3.2.7. When the heater operates in external circulation mode, no water and debris shall enter the cold air intake.
3.2.8.
When the heater operates in internal circulation mode, the hose placement needs to prevent heated air from entering the air intake again. The intake air should always come from the cooler area.
6
4Kw Air Fuel Heaters
7
4Kw Air Fuel Heaters 3.3 Installation of fuel supply system
The fuel supply system of the heater is shown in the following figure. NOTICE
We strongly recommend installing the standpipe instead of using the auxiliary
fuel port for better reliability and performance. Auxiliary fuel port may be
used only under 5000ft ASL. Any standpipe with an internal diameter of 2-2.5mm
will work.
3.3.1
The clip with rubber mounting bracket shall be used to secure the fuel pump. The outlet of the fuel pump should be inclined upward at 15~35 degrees. The fuel line from the fuel pump to the heater shall rise gradually.
8
3.3.2
4Kw Air Fuel Heaters The installation location of the fuel pump shall avoid high temperature components. Do not use the fuel pump at a temperature higher than 20 °C.
3.3.3
The height difference between the fuel surface level and the fuel pump, and the height difference between the fuel pump and the heater will generate pressure in the fuel line. As a result, these dimensions should meet the following requirements: a 3m, b 0.5m, c2m. (b 0.15m is required for a sealed fuel tank due to negative pressure)
NOTICE
1. Check the air vent of the fuel tank during installation.
2. After the fuel line is cut, ensure that the cut surface is round and does not affect the fuel supply.
9
4Kw Air Fuel Heaters 3.3.4 Installation of fuel filter
The fuel filter must be installed before the inlet of the fuel pump. Notice
the fuel flow direction icon. It should point upward at 0-90° as shown. NOTICE
The fuel filter needs to be replaced every two years and the fuel line
connector and clip must be replaced at the same time.
3.3.5 Installation of fuel line 3.3.5.1 The fuel pipe shall be installed to
prevent scratching and hitting
by sharp objects and debris. It should be installed away from hot components
of the vehicle. If necessary, nylon corrugated sleeves and other protective
accessories shall be installed. The fuel line must be secured with zip tie,
and the distance between zip ties shall not be greater than 100cm. 3.3.5.2 To
prevent air from entering the fuel line, use the genuine rubber connectors and
clamps to connect fuel lines as shown in the images below.
10
4Kw Air Fuel Heaters
A Correct
B Wrong
3.3.6 Installation of fuel standpipe
3.3.6.1 The fuel standpipe draws fuel from the vehicle fuel. A 25 ± 0.2mm hole
needs to be opened on a flat surface of the fuel tank or the fuel sender unit.
The gap between the lower end of the standpipe and the bottom of the fuel tank
needs to be at least of 25mm.
NOTICE: The genuine standpipe can only be used with metal fuel tanks. For
plastic fuel tank, alternative standpipe needs to be purchased separately.
11
4Kw Air Fuel Heaters 3.4 Installation of electrical components
3.4.1
The heater control switch is connected with a 4pin connector. Do not install the control switch right near the hot air outlet or the cabin door to avoid constant turning on and off at thermostat mode.
3.4.2 A 20A fuse is used at the in-line fuse box. The red and black cable connect to the power supply.
3.4.3
The fuel pump connector is not pre-installed for easier routing through the floor. Install the connector by inserting the wires all the way into the connector until hearing a click. The fuel pump cable is non-polarized. Installing the connector is irreversible.
3.5 Installation of air intake and exhaust pipe
3.5.1
The air intake pipe of the heater is an aluminum coated plastic corrugated pipe. It connects to the air intake of the heater and is secured with the clamp. The air intake must be placed outside the vehicle and away from any other exhaust.
3.5.2
The air intake pipe shall be arranged to prevent water from entering the pipe, and prevent it from being scratched by sharp objects. The intake pipe shall be fixed on the vehicle with the clamp.
3.5.3
Exhaust pipe is stainless steel corrugated pipe. It connects to the exhaust port of the heater and is secured with a clamp. The exhaust gas from the exhaust pipe shall be discharged directly to the outside of the vehicle. The outlet of the exhaust pipe should be at least 4ft away from any openings on the vehicle.
12
3.5.4
4Kw Air Fuel Heaters The caps on the intake and exhaust pipes shall be intact and shall not be damaged or removed. If the working environment contains solid particles or dust for a long time, an air filter should be installed
3.5.5 The exhaust pipe shall be arranged to minimize bending to ensure smooth exhaust.
3.5.6 The outlet of the exhaust pipe must not have any upward bends and must not face the vehicle moving direction.
3.5.7 The intake and exhaust pipe shall be arranged so that the pipe will not be blocked by mud, rain, snow and other objects.
3.5.8
When the heater is operating, the temperature of the exhaust pipe is very high. The exhaust pipe should be placed away from non-heat-resistant surfaces. The exhaust outlet shall point vertically downward with an angle of 90 °± 10.
3.5.9 A heat shield should be installed if there is risk for people to touch the exhaust pipe.
13
4Kw Air Fuel Heaters 3.5.10 The air intake pipe and exhaust pipe shall always
bend
downward. Otherwise, a 5mm condensate drain hole shall be opened at the lowest
point of the pipe. If bending is required, the bending radius of the pipe
shall not be less than 50mm. In addition, the sum of all bending angles shall
not exceed 270°.
IV. Operation
4.1 Basic Operation To turn on/off the unit, long press 2s at temp mode/ power
mode page. When the unit is turned off, note that the actual fan on the unit
will not stop until the heat exchanger reaches a safe temperature. To switch
between modes and pages, short press the knob and the screen will cycle
through all the pages. To change the setting in a page, turn the knob to move
the cursor till the target option is flashing. Short press and turn the knob
to edit. To move to the next page, move the cursor to “NEXT” and short press.
To switch between modes, turn the knob in either direction at the desired mode
page. You will need to slightly change the set temperature/ output to change
the mode. For example, if you want to switch from power mode to thermostat
mode, change the set temp from 75 to 76 or 74 and the heater will operate in
thermostat mode. Th heater always operates in the mode at which you changed
settings. The mode can be switched when the heater is operating. A turning fan
icon indicates which mode the unit is in.
WARNING DO NOT turn the unit on when the cooling program is in progress. The
screen will display “COOLING DOWN, DO NOT RESTART”. You may restart the unit
when the message is gone.
14
4Kw Air Fuel Heaters WARNING Do not cut off the power from the heater in any
other way. Doing so will cause the burner carbon build-up and various damage
to the accessories.
4.2 Elevation Display An onboard barometer measures the air pressure and
adjust the fuel-air mix ratio depending on the elevation you are at. Due the
characteristic of the sensor and the temperature variance, the normal error
range for the displayed elevation number is ±1500ft relative to the actual
elevation. When operate below 1500ft ASL, the display will show “AT SEA LEVEL”
or “000 ft.
4.3 Start the heater for the first time For fuel line within 6ft, no priming
is required, and the heater can be started as usual. It may take 2-3 tries for
the fuel to reach to heater. For fuel line longer than 6ft, it is recommended
to enter “QUICK PUMP FUEL” page to prime the fuel line manually. See detailed
instructions in the “QUICK PUMP FUEL” section.
4.4 Temp Mode (Thermostat) In thermostat mode, the unit will adjustment power
output automatically to the maintain the room temperature at the set value. In
temp mode page, the screen displays the following info: cabin temperature,
system time, elevation, operating status, timer status and error codes. If
there is an auto run scheduled, an alarm clock icon will show. Long press 2s
to turn/ off the unit. The fan icon rotates when the unit is running.
15
4Kw Air Fuel Heaters To set target temperature, rotate the dial. Once set,
leave the control switch for 3s and the new target temperature will be saved.
Display will go back to main screen and show ambient temperature.
If the ambient temperature is six degrees higher than the set temperature, the
heater will automatically enter standby mode. At standby mode, fan icon does
not turn, and the display shows SET TEMP REACHED. Once the temperature is six
degrees lower than the set temperature, the heater will automatically start.
4.5 Power Mode In power mode, the unit always runs at set power output level.
There are five output levels. In power mode page, the screen displays the
following info: output level, system time, elevation, operating status, timer
status and error codes. To change the power output, turn the dial.
16
4Kw Air Fuel Heaters 4.6 Auto Run
After an auto run is scheduled, the unit will automatically turn on and
operate in the last mode the unit was in with the previous setting (target
temperature or power output level). To schedule an auto run, turn on auto run
at “AUTO START TIME” page and set a starting time. The second row shows the
system time. Toggle the ON/OFF option to ON at the left bottom corner of the
screen. When the auto run is scheduled, an alarm clock icon will appear in the
mode page. The unit will automatically start every day at the scheduled time
till the feature is turned off. Move the cursor to “NEXT” and press the knob
to save.
In “AUTO RUN TIME” page, turn the knob to set the duration for auto run. Move
the cursor to “NEXT” and press the knob to save.
4.7 Set System Time This page sets the time for the system. Notice the system
time resets when the power is disconnected. Move the cursor to “NEXT” and
press the knob to save.
17
4Kw Air Fuel Heaters
4.8 Quick Pump Fuel The fuel pump can be turned on manually through this page
to prime the fuel line. Long press the knob for 2s and the fuel pump will
start. Closely monitor the fuel level in the fuel line and short press to stop
the fuel pump when the fuel gets close to the unit. Excessive fuel in the
combustion chamber could cause incomplete combustion and difficulty in
starting up.
To maximize the lifespan of the unit, the maximum continuous run time is 48h.
Once 48h is reached, the unit will power cycle and continue operation.
18
4Kw Air Fuel Heaters
V. Electrical Diagram
19
4Kw Air Fuel Heaters
VI. Error Codes and Troubleshooting
Error Code 01 02 03 04
05 06 07 08 09 10 11 12 13
Failure
Troubleshooting
Ignition failure
Check the fuel line to make sure the fuel can
flow freely. Add fuel if fuel level is low.
Combustion interruption
Check the fuel line to make sure the fuel can
flow freely. Add fuel if fuel level is low.
Power supply voltage abnormal
Make sure the battery is charged and the
voltage matches.
Heat exchanger overheat
Check the indoor air intake and outlet and
make sure there is no obstruction. Check
whether the housing leaks air.
Ignition sensor abnormal
Check the green temperature sensor
connector or replace the composite sensor
Outlet temperature sensor abnormal Check the blue temperature sensor connector
or replace the sensor
Fuel pump abnormal
Check the fuel pump wiring harness and
connector
Fan motor abnormal
Check the motor connector or replace motor
Inlet temperature sensor abnormal Replace control unit
Glow plug abnormal
Replace glow plug
Environment temperature abnormal The heater cannot operate below -40°C or
above 40 °C
Elevation too high or too low
Triggers when lower than -100m ASL or higher
than 5100 m ASL. Disregard
Fan speed abnormal
Check whether the fan is stuck or blocked
20
4Kw Air Fuel Heaters
VII. Maintenance
7.1 During the season when the heater is not used, the heater power should be
disconnected, and the heater should be kept clean and dry. The heater circuit
connector should be routinely inspected for rust and loosening.
7.2 The heater should be operated at least once a month, for no less than 15
minutes per run, to prevent mechanical components such as the fuel pump and
the motor from malfunctioning.
7.3 The fuel line needs to be inspected frequently for leakage.
7.4 The inlet end of the housing, air intake. and exhaust ducts should be
checked frequently for any foreign materials blocking the channel.
7.5 After ten years, the heat exchanger, exhaust pipe and the composite sensor
must be replaced with genuine part supplied by the manufacturer.
7.6 During welding operations to the vehicle, the positive end of the heater
should be removed from the battery and properly isolated to prevent damage to
the control unit. During transport, storage, the heater’s ambient temperature
should not exceed – 40 °C to 85°C.
8 The heater may have circuit failure due to the following reasons: corrosion
of connector, poor contact of connector, incorrect connector insertion,
corrosion of wire or fuse, etc. Quarterly inspection is recommended to prevent
circuit failure.
21
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>