User Manual Spring series LFP Battery
RW-M6.1
V2.0A
About This Manual
The manual mainly describes the product information, guidelines for
installation, operation, and maintenance. The manual cannot include complete
information about the solar photovoltaicenergy storage hybrid system.
How to Use
This Manual Read the manual and other related documents before performing any
operation on the battery. Documents must be stored carefully and be always
available. Contents may be periodically updated or revised due to product
development. The information in this manual is subject to change without
notice. The latest manual can be acquired via service-ess@deye.com.cn
(www.deyeess.com).
Safety Introductions
Reminding
- It is very important and necessary to read the user manual carefully (in the accessories) before installing or using battery. Failure to do so or to follow any of the instructions or warnings in this document can result in electrical shock, serious injury, or death, or can damage battery, potentially rendering it inoperable.
- If the battery is stored for long time, it is required to charge them every six months, and the SOC should be no less than 50%.
- Battery needs to be recharged within 48 hours after fully discharged.
- Do not expose cable outside.
- All the battery terminals must be disconnected for maintenance.
- Please contact the supplier within 24 hours if there is something abnormal.
- Do not use cleaning solvents to clean battery.
- Do not expose battery to flammable or harsh chemicals or vapors.
- Do not paint any part of Battery, include any internal or external components.
- Do not connect battery with PV solar wiring directly.
- The warranty claims are excluded for direct or indirect damage due to items above.
- Any foreign object is prohibited to insert into any part of battery.
Warning
1.1 Before Connecting
- After unpacking, please check product and packing list first, if product is damaged or lack of parts, please contact with the local retailer.
- Before installation, be sure to cut off the grid power and make sure the battery is in the turned-off mode.
- Wiring must be correct, do not mistake the positive and negative cables, and ensure no short circuit with the external device.
- It is prohibited to connect the battery and AC power directly.
- Battery system must be well grounded and the resistance must be less than 1Ω.
- Please ensured the electrical parameters of battery system are compatible to related equipment.
- Keep the battery away from water and fire.
1.2 In Using
- If the battery system needs to be moved or repaired, the power must be cut off and the battery is completely shut down.
- It is prohibited to connect the battery with different type of Battery.
- It is prohibited to put the batteries working with faulty or incompatible inverter.
- It is prohibited to disassemble the battery.
- In case of fire, only dry fire extinguishers can be used. Liquid fire extinguishers are forbidden.
- Please do not open, repair, or disassemble thebattery except staffs from DEYE or authorized by DEYE. We do not undertake any consequences or related responsibility which because of violation of safety operation or violating of design, production, and equipment safety standards.
Introduction
- RW-M6.1 lithium iron phosphate battery is one of new energy storage products developed and produced by DEYE, it can be used to support reliable power for various types of equipment and systems.
- RW-M6.1 is especially suitable for application scene of high power, limited installation space and long cycle life.
- RW-M6.1 has built-in BMS battery management system, which can manage and monitor cells information including voltage, current and temperature. What’s more, BMS can balance cells charging and discharging to extend cycle life.
- Multiple batteries can connect in parallel to expand capacity and power in parallel for larger capacity and longer power supporting duration requirements.
2.1 Product Features
- The whole module is non-toxic, non-polluting, and environmentally friendly.
- Cathode material is made from LiFePO4 with safety performance and long cycle life.
- Battery management system (BMS)has protection functions including over-discharge, over-charge, over-current and high & low temperature.
- The system can automatically manage charge and discharge state and balance current and voltage of each cell.
- Flexible configuration, multiple battery modules can be in parallel for expanding capacity and power.
- Adopted self-cooling mode rapidly reduced system entire noise.
- The module has less self-discharge, up to 6 months without charging it on shelf, no memory effect, excellent performance of shallow charge and discharge.
- Battery module communication address auto networking, easy maintenance, support remotely monitoring and upgrade the firmware.
- High-power density: flat design, wall-mounted and floor-mount, saving installation space.
2.2 Product Overview
This section details the front and side panel of the interface functions.
RW-M6.1 Product Interface
- Battery negative
- Battery positive
- Pressure release valve
- Parallel communication port IN
- Inverter CAN/RS485 port PCS
- Battery indicators (RUN, ALM, SOC)
- Foldable handle
- USB port for update firmware
- Parallel communication port OUT
- Grounding bolt
- Power switch
Power Switch
Power Switch: to turn ON/OFF the whole battery BMS standby, no power output.
RUN
RUN LED: 1 green LED lighting to show the battery running status
ALM
Alarm LED: 1 red LED lighting to show the battery is under protection.
SOC
SOC LED: 5 green LEDs to show the battery’s current capacity.
PCS
Inverter communication terminal: (RJ45 port) follow the CAN protocol (baud
rate: 500K), used to output battery information to the inverter. IN
Parallel Communication Terminal: (RJ45 port) Connect “out” Terminal of
Previous battery for communication between multiple parallel batteries.
OUT
Parallel Communication Terminal: (RJ45 port) Connect “IN” Terminal of Next
battery for communication between multiple parallel batteries. LED Status Indicators Instructions
RUN LED, green, long lighting when charging and blink when discharging.
ALM LED, red, long bright if equipment protected.
SOC LED, Battery capacity indicator,5 green LED, each light represents 20%
capacity.
Condition | RUN | ALM | SOC1 1 SOC 2 1 SOC 3 1 SOC 4 1 SOC 5 |
---|---|---|---|
Power off | off | ||
Charge | Blink | off | ****Show SOC & highest LED blink |
Discharge or Idle | off | Show SOC & long bright | |
Alarm | off | Other LEDs are same as above. | |
System error/Protect | |||
Upgrade | Blink Fastly | ||
Critical Error | Blink Slowly |
Grounding bolt
For the battery connecting to the PE.
BMS function:
Protection and Alarm | Management and Monitor |
---|---|
Charge/Discharge End | Intelligent Protect Mode |
Charge Over Voltage | Intelligent Charge Mode |
Discharge Under Voltage | Protect, Charge Current Limit |
Charge/Discharge Over Current | Intelligent Protect Mode |
High/Low Temperature(cell/BMS) | Intelligent Protect Mode |
Short Circuit | Protect |
2.3 Product Size 2.4 Technical Data
Main Parameter | RW-M6.1 |
---|---|
Battery Chemistry | LiFePO4 |
Capacity (Ah) | 120 |
Scalability | Max.32 pcs in paralle1(196kWh) |
Nominal Voltage (V) | 51. |
Operating Voltage(V) | 43.2-57.6 |
Energy (kWh) | 6. |
Usable Energy (kWh) (II | 6. |
Charge/Discharge Current (A) | Recommend 121 |
Max. 121 | 100 |
Peak(2mins,25°C) | 150 |
Other Parameter
Recommend Depth of Discharge| 90%
Dimension (W/H/D, mm)| 475’720.145 (Without Base, depth of 161mm with
Hanging Board)
Weight Approximate(kg)| 58
Master LED indicator| 5 LED (SOC 20%-100%)
3 LED (working, alarming, protecting)
IP Rating of enclosure| IP65
Working Temperature| C
Charge: 0°C – +55°C
Discharge: -20°C – +55°C
Storage Temperature| -20°C – +35°C
Humidity| 5%-95%
Altitude| s2000m
Installation| Wall-Mounted, Floor-Mounted
Communication Port| Certification
Certification| UN38.3, IEC62619, CE
[1] DC Usable Energy, test conditions: 90% DOD, 0.5C charge & discharge at
25°C. System usable energy may vary due to system configuration parameters.
[2] The current is affected by temperature and SOC.
2.5 Product application solutions
The following illustration shows basic application of this battery.
It also includes following devices to have a complete running system.
– Generator or Utility
– PV modules
– Hybrid Inverters (Charge & Discharge)
Consult with your system integrator for other possible system architectures
depending on your requirements.
The picture is only an effect picture, please refer to the actual product, the final interpretation right belongs to DEYE.
Parts List
Check the equipment before installation. Please make sure nothing is damaged in the package. You should have received the items in the following package.
Preparations for Installation
4.1 Explanation of Symbol
DANGER/HIGH VOLTAGE INSIDE
CAUTION:
– Do not disassemble or alter the battery in any way.
– Do not use the battery for purposes not described in its documentation.
– Do not drop,strike, puncture, or step on the battery.
– In case of electeolyte leakage, keep leaked electrolyte away from contact
with eyes or skin, immediately clean with water and seek help from a doctor.
– Do not put the battery into a fire. Do not use it or leave it in a place
near fire, heaters, or high temperature sources
– Do not submerge the battery in water, or expose it to moisture.
– Do not allow the terminals to contact exposed wire or metal.
– The battery is heavy and can cause injury if not handled safely.
– Keep out of reach of children or animals.
4.2 Tools
These tools are required to install the battery. NOTE:
Use properly insulated tools to prevent accident tale electric shock or short
circuits. If insulated tools are not available, cover the entire exposed metal
surfaces of the available tools, except their tips, with electrical tape.
4.3 Safety Gear
It is recommended to wear the following safety gear when dealing with the
battery pack.
Mounting instructions
5.1 Installation Precaution
Lithium battery is designed for outdoor use (IP65). But please avoid direct
sunlight, rain exposure, snow laying up during installation and operation.
Please make sure the installation site meets below conditions:
- Not in direct sunlight.
- Not in areas where highly flammable materials are stored.
- Not in potential explosive areas.
- Not in the cool air directly.
- Not higher than altitude of about 2000 meters above sea level.
- Not in environment of precipitation or humidity (>95%).
5.2 Installation Location
Make sure that the installation location meets the following conditions:
- The area is completely water proof.
- The wall is flat and level.
- There are no flammable or explosive materials.
- The ambient temperature is within the range from -20°C to 50°C.
- The temperature and humidity are maintained at a constant level.
- There is minimal dust and dirt in the area.
- The distance from heat source is more than 2 meters.
- The distance from air outlet of inverter is more than 0.5 meters.
- Do not cover or wrap the battery case or cabinet.
- Do not place at a children or pet touchable area.
- The installation area shall avoid of direct sunlight.
- There are no mandatory ventilation requirements for battery module, but please avoid of installation in confined area. The aeration shall avoid of high salinity, humidity, or temperature.
CAUTION
If the ambient temperature is outside the operating range, the battery pack
stops operating to protect itself. The optimal temperature range for the
battery pack to operate is 15°C to 35°C.
Frequent exposure to harsh temperatures may deteriorate the performance and
life of the battery pack.
5.3 Mounting the Battery
CAUTION
Remember that this battery is heavy! Please be careful when lilting out from
the package.
5.3.1 Wall-Mounted method
The installation location description should meet the size requirements of the
figure below:a) Use the 6 screws of
M610 to fix the backplane to the back of the battery as shown in Figure 5-1.
b) Choose the recommend
drill head (as shown in Figure 5-2) to drill 4 holes on the wall,100mm-110mm
deep.
c) Use a proper hammer to fixing the hanging plate to the wall, fit the
expansion bolt into the holes, as shown in Figure 5-2. d) Fasten the screw head of the expansion bolt to finish the
mounting.
e) Carry the battery and holding it, Fix the battery on the plate after fixing
the hanging plate to the wall. Ensure that the upper and lower positions of
the battery backplane hook are accurately buckled on the hanging plate, as
shown in Figure 5-3. 5.3.2 Floor-Mounted method
a) Use the 4 screws of M610 to fix the left and right retaining ears to the
back of the battery, as shown in Figure 5-4.b) Stand the battery on the side of the wall, mark the
location of the fixing hole, Choose the recommend drill head (as shown in
below picture) to drill 2 holes on the wall,100-110mm deep, as shown in Figure
5-2 and Figure 5-5. c) Use a
proper hammer to fixing the battery to the wall, fit the expansion bolt into
the holes, as shown in Figure 5-2.
d) Adjust the left and right screws to the appropriate position to ensure that
the battery is perpendicular to the ground, as shown in Figure 5-6. 5.3.3 The installation is complete(Reference)
5.4 Batteries in parallel
5.4.1 Parallel mode 1 (It is suitable for scenarios where the inverter
power ≤ 12kW)
CAUTION
It should be noted that the maximum current of the battery terminals is 250A
(inverter power must not exceed 12kW), exceeding 250A will cause heating of
the connectors and cable, and in severe cases, it willcause a fire accident.
If the inverter total power
exceeds 12kW, the parallel mode must be used mode 2. Schematic diagram of
parallel connection of low-power system batteries: 5.4.2 Parallel mode 2 (It is suitable for scenarios where the
inverter total power ≥ 12kW)
Schematic diagram of parallel connection of high-power system batteries:
5.5 Visual Inspection of the
Connection
After connecting the battery, check for:
- Usage of positive and negative cables.
- Connection of the positive and negative terminals.
- All the bolts are tightened.
- Cables fixation and the appearance.
- The installation of the protecting cover.
5.6 Activate the Product
A. Hang the RW-M6.1 battery on the wall as shown on 5.4.
B. Connect the wires according to the picture on 5.4.
C. Turn on all battery power in turn.
Start the Battery:
After installation, wiring, and configuration are completed, you must check
all the connection.
When the connections are correctly, and then press power button to activate
the battery. The green working light on the front panel of the battery
flashes, indicating that the battery system is normal.
Inspection, Cleaning and Maintenance
6.1 General Information
- The battery product is not fully charged. It is recommended that the installation be completed within 3 months after arrival;
- During the maintenance process, do not re-install the battery in the battery product. Otherwise, the performance of the battery will be reduced;
- It is forbidden to dismantle any battery in the battery product, and it is forbidden to dissect the battery;
- After the battery product is over-discharged, it is recommended to charge the battery within 48 hours. The battery product can also be charged in parallel. After the battery product is connected in parallel, the charger only needs to connect the output port of any product battery.
- Never attempt to open or dismantle the battery! The inside of the battery does not contain serviceable parts.
- Disconnect the Li-Ion battery from all loads and charging devices before performing cleaning and maintenance activities
- Place the enclosed protective caps over the terminals before cleaning and maintenance activities to avoid the risk of contacting the terminals.
6.2 Inspection
- Inspect for loose and/or damaged wiring and contacts, cracks, deformations, leakage, or damage of any other kind. If damage to the battery is found, it must be replaced. Do not attempt to charge or use a damaged battery. Do not touch the liquid from a ruptured battery.
- Regularly check the battery’s state of charge. Lithium Iron Phosphate batteries will slowly self-discharge when not in use or whilst in storage.
- Consider replacing the battery with a new one if you note either of the following conditions:
– The battery run time drops below 70% of the original run time. – The battery charge time increases significantly. ‘
6.3 Cleaning
If necessary, clean the Li-Ion battery with a soft, dry cloth. Never use
liquids, solvents, or abrasives to clean the Li-Ion battery.
6.4 Maintenance
The Li-Ion battery is maintenance free. Charge the battery to approximately >
80% of its capacity at least once every year to preserve the battery’s
capacity.
6.5 Storage
- The battery product should be stored in a dry, cool, and cool environment;
- Generally, the maximum storage period at room temperature is 6 months. When the battery is stored over 6 months, it is recommended to check the battery voltage. If the voltage is higher than 51.2V, it can continue to store the battery. In addition, it is needed to check the voltage at least once a month until the voltage is lower than 51.2V. When the voltage of the battery is lower than 51.2V, it must to be charged according to the charging strategy.
- The charging strategy is as follows: discharge the battery to the cutoff voltage with 0.2C(24A) current, and then charge with 0.2C(24A) current for about 3 hours. Keep the SOC of the battery at 40%-60% when stored;
- When the battery product is stored, the source of ignition or high temperature should be avoided and it should be kept away from explosive and flammable areas.
Troubleshooting
To determine the status of the battery system, users must use additional
battery status monitoring software to examine the protection mode. Refer to
the installation manual about using the monitoring software. Once the user
knows the protection mode, refer to the following sections for solutions.
Table 7-1: Troubleshooting
Fault Type| Fault Generation condition| Possible Causes|
Troubleshooting
---|---|---|---
BMS fault| The cell voltage sam- pling circuit is faulty. The cell temperature
sampling circuit is faulty| The welding point for cell voltage sampling is
loose or disconnected.
The voltage sampling terminal is disconnected.
The fuse in the voltage sam- pling circuit is blown.
The cell temperature sensor has failed.| Replace the bat-tery.
Electrochemical cell fault| The voltage of the cell is low or unbalanced.| Due
to large self- discharge. the cell over discharges to below 2.0V after long
term storage.
The cell is damaged by external factors, and short circuits, pinpricks, or
crushing occur.| Replace the bat-tery.
Overvoltage protection| The cell voltage is greater than 3.65 Vin charging
state.
The battery voltage is greater than 58.4 V.| The busbar input voltage ex-
ceeds the normal value. Cells are not consistent. The
capacity of some cells deterio- rates too fast or the internal resistance of
some cells is too high.| If the battery can-not be recovered due to protection
against abnormal-ity contact local engineers to rectify the fault
Under voltage protection| e battery voltage is The
less than 40V.
The minimum cell volt- age is less than 2.5V| The mains power failure has
lasted for a long time.
Cells are not consistent The capacity of some cells deterio- rates too fast or
the internal resistance of some cells is too high.| Same as above
Charge or dis- charge high temperature protection| The maximum cell
temperature is greater
than 60t| The battery ambient tempera-. ture is too high
There are abnormal heat sources around| Same as above
Charge low temperature protection| The minimum cell tem- perature is less than
0 C| The battery ambient tempera-ture is too low.| Same as above.
Discharge low temperature protection| The minimum cell tem- perature is less
than
-20 C| The battery ambient tempera-ture is too low.| Same as above.
By checking the above data and sending the data to the service personnel of our company, the service personnel of our company will reply the corresponding solution after receiving the data.
Battery recovery
Aluminum, copper, lithium, iron, and other metal materials are recovered from
discarded LiFePO4 batteries by advanced hydrometallurgical process, and the
comprehensive recovery efficiency can reach 80%. The specific process steps
are as follows:
8.1 Recovery process and steps of cathode materials
Aluminum foil as collector is amphoteric metal. Firstly, it is dissolved in
NaOH alkali solution to make aluminum enter the solution in the form of
NaAlO2. After filtration, the filtrate is neutralized with sulfuric acid
solution and precipitated to obtain Al (OH)3. When the pH value is above 9.0,
most of the aluminum precipitates, and the obtained Al (OH)3 can reach the
level of chemical purity after analysis.
The filter residue is dissolved with sulfuric acid and hydrogen peroxide, so
that lithium iron phosphate enters the solution in the form of Fe2 (SO4) 3 and
Li2SO4, and is separated from carbon black and carbon coated on the surface of
lithium iron phosphate. After filtration and separation, the pH value of the
filtrate is adjusted with NaOH and ammonia water. First, iron is precipitated
with Fe (OH) 3, and the remaining solution is precipitated with saturated
Na2CO3 solution at 90 ℃.
Since FePO4 is slightly dissolved in nitric acid, the filter residue is
dissolved with nitric acid and hydrogen peroxide, which directly precipitates
FePO4, separates impurities such as carbon black from acid solution, leaches
Fe (OH) 3 from filter residue respectively, and precipitates Li2CO3 with
saturated Na2CO3 solution at 90 ℃.
8.2 Recovery of anode materials
The recovery process of anode materials is relatively simple. After the
separation of anode plates, the purity of copper can be more than 99%, which
can be used for further refining electrolytic copper.
8.3 Recovery of diaphragm
The diaphragm material is mainly harmless, and has no recycling value.
8.4 List of recycling equipment
Automatic dismantling machine, pulverizes, wet gold pool, etc.
Transportation Requirements
The battery products should be transported after packaging and during the
transportation process, severe vibration, impact, or extrusion should be
prevented to prevent sun and rain.
It can be transported using vehicles such as cars, trains, and ships.
Always check all applicable local, national, and international regulations
before transporting a Lithium Iron Phosphate battery.
Transporting an end-of-life, damaged, or recalled battery may, in certain
cases, be specially limited or prohibited.
The transport of the Li-Ion battery falls under hazard class UN3480, class 9.
For transport over water, air and land, the battery falls within packaging
group PI965 Section I.
Use Class 9 Miscellaneous Dangerous Goods and UN Identification labels for
transportation of lithium-ion batteries which are assigned Class 9. Refer to
relevant transportation documents. Figure 9-1: Class 9 Miscellaneous Dangerous
Goods and UN Identification Label