FRICO ICF Series Ceiling Fan Instruction Manual
- June 13, 2024
- FRICO
Table of Contents
FRICO ICF Series Ceiling Fan
Product Information
Product Name: ICF 20/55
Product Code: 5.671.084.210
Dimensions:
- Height: 545mm
- Weight: 6.2kg
Installation:
- Item Number: 11800, 11729
- Type: ICF20, ICF55
- Recommended Installation Height: 2.7m – 2.3m
Maintenance:
- Enclosure Class ICF20: IPX0
- Enclosure Class ICF55: IPX5
Product Usage Instructions
General Instructions:
- Read the instructions carefully before installation and use.
- Keep the manual for future reference.
- The guarantee is only valid if the units are used as intended by the manufacturer and in accordance with the Frico mounting and operating instructions.
Areas of Use:
- Roof fans are primarily used to even out the temperature in premises with high ceilings.
- The warm air that collects under the ceiling is pressed down to heat the occupied areas underneath.
- This form of air mixing also has a quicker heating effect on cold goods, improves drying, and reduces the risk of cold irradiation.
Placement:
- Place the fans symmetrically in the premises to achieve optimum temperature spread.
- Ensure that the fans are installed where there is no risk to people or contact with rotating blades.
- Avoid placing the fans where they blow air directly on people to prevent discomfort from draughts.
Fan Installation and Electrical Connection:
Refer to figures 1-19 in the user manual for detailed instructions on fan installation and electrical connection.
Service and Maintenance:
Refer to figures 20-22 in the user manual for detailed instructions on service and maintenance.
Safety:
- This appliance can be used by children aged 8 years and above, as well as individuals with reduced physical, sensory, or mental capabilities.
- Children should not play with the appliance.
- Cleaning and user maintenance should not be performed by children without supervision.
Power Supply Specifications:
- The power supply must correspond to the electrical data on data plate A (refer to figure 2).
- The roof fan(s) should only be wired by a competent electrician and in accordance with the latest edition of IEE wiring regulations.
Contact Information:
- Tel: +46 31 336 86 00
- Email: mailbox@frico.se
- Website: www.frico.net
Note: For the latest updated information and information about your local contact, please visit the website.
Dimension
Item number| Type| Height [mm]| Ø
[mm]
| Weight [kg]
---|---|---|---|---
11800| ICF20| 545| 1422| 6,2
11729| ICF55| 545| 1422| 6,2
Assembly and operating instructions
General Instructions
Read these instructions carefully before installation and use. Keep this
manual for future reference.
The guarantee is only valid if the units are used in the manner intended by
the manufacturer and in accordance with the Frico mounting and operating
instructions.
Areas of use
- Roof fans are chiefly used to even out the temperature in premises with high ceilings. The warm air that collects under the ceiling is pressed down so that it can heat the occupied areas underneath. Warm air escape via the ceiling are thereby reduced. This form of air mixing also has a quicker heating effect on cold goods, makes for better drying, and reduces the risk of cold irradiation.
- Enclosure class ICF20: IPX0
- Enclosure class ICF55: IPX5
Placement
The fans should be placed symmetrically in the premises where they can provide optimum temperature spread. Make sure the fans are always installed where there is no risk to people or of contact with objects from the rotating blades. Nor should they be placed where they blow air directly on people. Generally fan speed should be regulated so that they don’t cause draughts.
Fan installation and electrical connection
See fig. 1-19.
Max. surrounding temperature is +40 °C.
The roof fan(s) should only be wired by a competent electrician and in
accordance with the latest edition of IEE wiring regulations.
Service and maintenance
See fig. 20-22.
ICF20/55 is basically maintenance free, but should be checked on a regular
basis. Important! Check the hanging brackets to avoid the risk of the fan
falling down.
Before cleaning the unit or carrying out maintenance operations, turn the main
switch off and remove the plug from the power supply. When several units are
controlled with a common control device the fan speed could differ from one
unit to another. In most cases these differences will disappear when the fans
have been running for some time (about a week). Another reason could be that
the lower protective cover is squeezed to tight to the fan, adjust the coves
if necessary.
Safety
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Specifications for the power supply must correspond to the electrical data on data plate A (fig. 2).
Wiring diagrams ICF20/55
Main office
Frico AB
Industrivägen 41
SE-433 61 Sävedalen mailbox@frico.se
Sweden www.frico.net
For latest updated information and information about your local contact:
www.frico.net
Tel: +46 31 336 86 00
References
Read User Manual Online (PDF format)