legrand 412015 CX3 With Netatmo Starter Pack User Manual
- June 13, 2024
- Legrand
Table of Contents
legrand 412015 CX3 With Netatmo Starter Pack User Manual
Composition of this pack
This pack allows you to create a connected installation in your home.
Gateway module
| U|
P
consumption
|
F
---|---|---|---
-5°C +45°C| 100-240V~ 50/60Hz| 2W MAX| 2,4 à 2,4835Ghz
EN 60669-2-1
Connected Contactor
Control wiring authorized
F| | | | | | | | LED
**FLUO
| | | U| I**| Shedding
---|---|---|---|---|---|---|---|---|---|---|---|---|---
2,4 à 2,4835Ghz| Silent < 10dB| Planning| Measure| 4800W| 2400VA| EV plug
remote| 3840W| 650W| 3000W| 5°C +45°C| 100-240V~ 50/60Hz| 20A MAX| Connected
shedding compatible
_ **Imperative security precaution
** The instructions for installation and use must be strictly observed in order to avoid the risk of electric shock or fire._
Your products are compatible with technology Apple Home Kit for control of your connected home. This allows you, for example, to control your products by voice through the wizard Siri voice from your iPhone, iPad, Home Pod or Apple Watch.
Unique code of installation Apple HomeKit to keep
Apple Home Kit: During the installation of the iOS mobile app, you will be
asked for this code.
Home Kit (using the House application)
To control this Home Kit-enabled accessory, the latest version of iOS or
iPadOS is recommended.
Controlling this HomeKit-enabled accessory automatically and away from home
requires a HomePod, Apple TV, or iPad set up as a home hub.
It is recommended that you update to the latest software and operating system.
Legal notice
Using products with the Apple HomeKit logo means that an electronic accessory
has been designed to connect specifically to the iPod, iPhone or iPad, and has
been certified by the developer to meet Apple’s performance standards.
Apple is not responsible for the operation of this device or its compliance
with safety and regulatory standards. Please note that using this accessory
with the iPod, iPhone, or iPad may affect wireless performance.
iPhone, iPod and iPad are registered trademarks of Apple Inc., registered in
the US and other countries.
App Store is a service mark of Apple Inc., registered in the U.S. and other
countries.
HomeKit and iPadOS are trademarks of Apple Inc. iOS is a trademark or
registered trademark of Cisco in the U.S. and other countries and is used
under licence.
Android, Google Play and Google Play badge are trademarks of Google LLC.
Installation step by step
-
Choose a location for the Gateway module, in the electrical cabinet :
If an internet box is present in the house, check with a smartphone that the Wifi signal level is sufficient. If the signal is not enough, try to bring the internet box to the electrical panel or add a WiFi repeater at the installation. -
Install the Gateway module in the electrical cabinet
OFF
Turn OFF the power at
**general circuit breaker
**
Cable the Gateway module under a circuit breaker
- Add the contactor to your connected installation
C1, C2:
MAX 2x 1.5mm² 2.5mm²
N, L, Load:
MAX 2x 2.5mm² 6mm
C1,C2, N, L, Load
MIN : 0.8Nm
MAX : 1.4Nm
Wiring examples
Thanks to its control circuit with integrated power and protection, you no
longer need to install a circuit breaker 2A to protect the control circuit if
you wire a contact between C1 and C2.
For the protection of the Connected Contactor, it is recommended to use a
circuit breaker or a gG fuse with current rating ≤ 20A.
controled by the energy supplier electric meter
Swimming pool pump and anothers motors
EV plug remote
Control of heaters through an installed central remote
Control of a power single line contactor by a connected contactor *
Control of a power three lines contactor by a connected contactor
: Non-functional consumption measurement when controlling a single line or a three lines power contactor by a connected contactor
N (neutral) = blue
L (Line) = Everything but blue and green/yellow
Line after contact = usually purple, orange…
- Complete your connected installation with additional products (not included in this pack):
Modules for the electrical cabinet
Sockets, switches and micromodules
Accessories and wireless push buttons
Wire wired products using the individual instructions provided in the
packaging of each of them.
The Legrand ecosystem is growing regularly, do not hesitate to consult the
website legrand.com to keep you informed.
- Configure the Gateway module and the Contactor
OFF
Turn off the power at
general circuit breaker
ON
Turn on the power at the
**general circuit breaker*
once the installation completed and controlled
-
In order to restart all connected products at the same time.
**: After wiring the installation, refit the front plate so that no active live part is accessible.- Finalize the installation in the Legrand Home + Control app
You also have the option of controlling your installation via a voice assistant. and can customize your scenarios via the Home + Control App.
Reset a Connected Contactor to remove it from a connected installation
Press the configuration button of the Connected Contactor (> 5 seconds) until the configuration indicator lights up in fixed red. It is no longer associated with the gateway present in the installation.
Use by manual control and status LED
Automatic Mode
OFF AUTO OFF AUTO ON
O
**ON
ON/OFF Mode
OFF
ON
To add this connected product and peripheral items in your connected installation, you must follow the instructions:**
- with Legrand Home + Control app (Parameters/Add new product)
- or consult the guides and instructions sheets on legrand.fr
www.legrand.fr/reference/412191
LEGRAND – Pro and Consumer Service – BP 30076
87002 LIMOGES CEDEX FRANCE • www.legrand.com
**UE SIMPLIFIED DECLARATION OF CONFORMITY
The undersigned,
Legrand
declares that the radio equipment listed on this instruction sheet are
compliant to the directive 2014/53/UE.
The full text of the UE declaration of conformity is available at the
following website:** www.legrandoc.com
References
- Legrand - Spécialiste des infrastructures électriques et numériques du bâtiment
- Welcome to Legrand - Legrand
- Legrand E-catalog International | Electrical Ranges of products & Connected Solutions