Model | Channels | Frequency | Certifications |
---|---|---|---|
SK- 910RD3 | 3 | 315MHz* | FCC, IC |
SK- 910RD4 | 4 | 315MHz* | FCC, IC |
SK-910RD3-4 † | 3 | 433.92MHz ‡ | CE |
SK-910RD4-4 † | 4 | 433.92MHz ‡ | CE |
The ENFORCER 3- and 4-Channel RF receivers meet the growing demand for multi- channel receivers with multiple independently controlled output modes and can be used to remotely control a variety of devices including garage doors, lights, motorized gates, lifts, or others. Now also dual frequency, they are even more flexible and compatible with all ENFORCER transmitters of the same frequencies, including both fixed and code-hopping CODEBUMP™ variants.
-
Flexible 10~24 VAC/VDC operating voltage
Simultaneously receive 315 and 433.92MHz signals with optional Extended Range Antenna -
Range up to 500ft (150m) or up to 1,000ft (300m) with optional Extended Range Antenna§
-
Independently programmable channels and up to 60 transmitter button codes per channel
-
Pushbutton programming, no jumpers to cut or switches to set
-
5 Output modes per channel—timed pulse (0.5~99 sec), timed pulse (1~99 min), toggle, latch, and follow (validity)
-
Compatible with all SECO-LARM transmitters of the same frequency.
Specifications
Model| SK-910RD3| SK-910RD4| SK-910RD3- 4| SK-
910RD4- 4
---|---|---|---|---
Operating frequency| 315MHz*| 433.92MHz †
Memory capacity| 60 per channel
Operating voltage| 10~24 VAC/VDC
Operating current| Standby| 16mA@12 VDC, 12mA@24 VDC
Active| 60mA@12 VDC, 50mA@24 VDC (both per channel)
Relay output modes| 0.5~99 sec momentary (default, 1s), 1~99 min
momentary, toggle, latch, follow (validity)
Relay contacts| Number| 3| 4| 3| 4
Rating| Form C 10A@14VDC
Connectors| Screw terminals, +, -, with NO/NC/COM per relay
Digital display| 2-Digit, 7-segment LED
Operating humidity| 5~95%, non-condensing
Operating temperature| 32°~167° F (0°~75° C)
Dimensions| 43/16″x7/8″x23/8″ (107x23x60 mm)
- Can simultaneously receive 433.92MHz signals with optional SK-93ERSD Extended Range Antenna.
- Can simultaneously receive 315MHz signals with optional SK-91ERSD Extended Range Antenna.
Overview
LED Display
Selector Button Operation
Enter programming mode| Press and hold for three seconds or more to
enter programming mode.
---|---
Select channel for programming| Programming mode defaults to channel 1
on entering. Press again to switch through channels in sequence.
Memory display| After entering programming mode and the desired channel,
within 2 seconds the LED will flash x number of times (where “x” is the number
of codes learned for that channel).
Delete all codes from a channel| After entering programming mode and the
desired channel, when the LED stops flashing, press and hold the selector
button at least 3 seconds or until the LED flashes three times.
Program the output mode| In programming mode select the desired channel.
Press the button again to display the current mode (P1~P5). To change, press
to cycle through the modes in sequence.
Program the timed pulse duration| After programming the output mode and
in P1 or P5 mode, press and hold the selector button to change the number of
seconds or minutes, respectively.
Installation Notes
- Mount the receiver out of sight in a location not exposed to weather or moisture and not surrounded by metal. Metal will block the signal resulting in reduced range.
- An optional Extended Range Antenna can be used to extend the range or activate dual frequency. To install, open the case, plug the antenna cable into the antenna plug (see Overview, pg. 2), remove the knockout on the back of the case cover and reinstall the cover.
Receiver| Extended Range Antenna| Result
---|---|---
SK-910RD3 or
SK-910RD4 (315MHz)
| SK-93ERSD (433.92MHz)| Receiver can also receive 433.92MHz transmitter
signals
SK-91ERSD (315MHz)| Extends the range to up to 1,000ft (300m)*
SK-910RD3-4 or
SK-910RD4-4 (433.92MHz)
| SK-91ERSD (315MHz)| Receiver can also receive 315MHz transmitter signals
SK-93ERSD (433.92MHz)| Extends the range to up to 1,000ft (300m)*
Programming
Entering Programming Mode
- Press and hold the selector button for at least 3 seconds. The LED display will flash L1, indicating channel 1. Press the selector to switch to another channel, in sequence, if desired.
- After 2 seconds, the display slowly flashes the number of codes stored and enters programming mode.
NOTE : If the selector button or no transmitter button is pressed within 15 seconds, the receiver exits programming mode.
Learning a New Transmitter Button Code
In programming mode with the desired channel selected and the LED indicator
still flashing, press the desired transmitter button once. The 3 horizontal
bars on the display will flash twice and the receiver will exit programming
mode. Repeat the entire process to learn other codes.
NOTES
- After entering programming mode, do not press the selector button again as it will then go to output mode programming.
- The indicator LED will flash a maximum of 15 seconds. If no transmitter button is pressed during this time, the receiver will exit code programming mode, and the LED will turn off.
- If a code has already been learned, the indicator LED slowly flashes two dashes. The code will not be learned twice.
- One channel can learn the codes of up to 60 transmitter buttons. If you try to learn an additional transmitter code, the earliest code learned will be deleted and the new code will be learned.
Clearing a Channel’s Memory
In programming mode, select the desired channel. While the display is flashing
the correct channel, press and hold the selector button 3 seconds or until the
LED flashes twice. All codes for the channel will be cleared.
Displaying a Channel’s Number of Codes Learned
In programming mode, select the channel. The LED will flash the channel’s
number of codes stored (15sec).
Programming a Channel’s Relay Output Mode
Each channel relay can be independently programmed to one of five output modes
for any transmitter button.
- P1 – 0.5~99 Second Timed Pulse (default, 1 second) – The transmitter button turns the relay ON for the programmed number of seconds.
- P2 – Toggle – Works like a toggle to alternately turn a device ON & OFF. Press the transmitter button once, and the relay turns ON. Press the transmitter button again, and the relay turns OFF.
- P3 – Latch – The transmitter button turns the relay ON. It stays ON even if a compatible transmitter button is pressed again. To turn OFF, press the selector switch on the receiver once to reset.
- P4 – Follow (Validity) – The relay status follows the transmitter button status and will remain active for as long as the transmitter button is pressed.
- P5 – 1~99 Minute Timed Pulse – The transmitter button turns the relay ON for the preset number of minutes.
In programming mode, and with the desired channel selected, follow the steps below to set the output mode:
- While the LED is flashing, press the selector button. The LED displays the current output mode (default P1).
- To change, press the selector button to scroll sequentially through the 5 output modes as shown in Fig. 1 until the desired mode appears.
- In mode P1 or P5, press and hold the selector button to change the seconds or minutes, respectively.
- When complete, wait 15 seconds for the receiver to automatically exit programming mode.
Sample Applications
FCC COMPLIANCE STATEMENT FCC ID: K4E951T4
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
Notice : The changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
IMPORTANT NOTE: To comply with the FCC RF exposure compliance
requirements, no change to the antenna or the device is permitted. Any change
to the antenna or the device could result in the device exceeding the RF
exposure requirements and void user’s authority to operate the device.
IMPORTANT : Users and installers of this product are responsible for
ensuring that the installation and configuration of this product complies with
all national, state, and local laws and codes.
SECO-LARM will not be held responsible for the use of this product in
violation of any current laws or codes.
California Proposition 65 Warning: These products may contain chemicals
which are known to the State of California to cause cancer and birth defects
or other reproductive harm. For more information, go to
www.P65Warnings.ca.gov.
WARRANTY : This SECO-LARM product is warranted against defects in
material and workmanship while used in normal service for one (1) year from
the date of sale to the original customer. SECO-LARM’s obligation is limited
to the repair or replacement of any defective part if the unit is returned,
transportation prepaid, to SECO-LARM. This Warranty is void if damage is
caused by or attributed to acts of God, physical or electrical misuse or
abuse, neglect, repair or alteration, improper or abnormal usage, or faulty
installation, or if for any other reason SECO-LARM determines that such
equipment is not operating properly as a result of causes other than defects
in material and workmanship. The sole obligation of SECO-LARM and the
purchaser’s exclusive remedy, shall be limited to the replacement or repair
only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any
special, collateral, incidental, or consequential personal or property damage
of any kind to the purchaser or anyone else.
NOTICE : The SECO-LARM policy is one of continual development and
improvement. For that reason, SECO-LARM reserves the right to change
specifications without notice. SECO-LARM is also not responsible for
misprints. All trademarks are the property of SECO-LARM U.S.A., Inc. or their
respective owners. Copyright © 2023 SECO-LARM U.S.A., Inc. All rights
reserved.
16842 Millikan Avenue, Irvine, CA 92606
Phone:949-261-2999 |
800-662-0800
Website:www.seco-larm.com
Email:sales@seco-larm.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>