Paruu R10 Wearable Breast Pump Hands Free Electric Portable Breast Pump User Manual

June 13, 2024
Paruu

Paruu R10 Wearable Breast Pump Hands Free Electric Portable Breast Pump User Manual

Paruu R10 Wearable Breast Pump Hands Free Electric Portable Breast Pump User
Manual

SAFETY INFORMATION

⚠ Warning

  1. Do not use this device if you have a cardiac pacemaker, implanted defibrillator, or other implanted metallic or electronic device. Such use could cause electrical interference or death.

  2. This breast pump is not intended for use by persons (including children) with impaired physical, sensory. or mental capabilities, or those lacking experience and knowledge. Such persons can only use this breast pump under the supervision of adult or after having received proper instruction concerning the use of the appliance by the person responsible for their safety.

  3. Danger: To reduce the risk of electrocution:
    • Always unplug electrical devices immediately after charging.
    • Do not use electrical devices while bathing, showering, driving, or swimming.
    • Do not reach for electrical products that have fallen into water, please unplug the power adapter from the wall outlet immediately.

  4. The wearable breast pump is a personal care item and for hygienic reasons should never be shared between mothers or resold from one mother to another. Either of these actions will void the warranty.

  5. If you are a mother who is infected with Hepatitis B, Hepatitis C, or Human Immunodeficiency Virus (HIV), pumping breast milk using the wearable breast pump will not reduce or remove the risk of transmitting the virus to your baby through your breast milk.

  6. Close supervision is necessary when the product is used near children or those with disabilities. Do not allow children or pets to play with the motor unit, packaging materials, or accessories.

  7. Use the product only for its intended use as described in this manual.

  8. Only use attachments or milk collection components recommended by the manufacturer.

  9. Check the power adapter before charging, never use the damaged power adapter.

  10. Never leave the device unattended when charging.

  11. Keep the product and all attachments away from heated surfaces.

  12. Never use it while sleeping or drowsy.

  13. Do not operate where aerosol spray products are being used or where oxygen is being administered.

  14. Do not use the device around explosive or flammable material, in an MRI environment, in a hyperbaric chamber, or near a fireplace or radiant heater.

  15. Avoid strangulation resulting from charging cables.

  16. Users are not allowed to repair the product on their own. Doing so invalidates any warranty. For repairs, send the product to the manufacturer or a designated franchise distributor.

  17. Always switch off the breast pump before attempting to remove the pump body from your breast, in order to release the vacuum.

  18. If irritation or discomfort occurs, discontinue use and see a doctor.

  19. Powered breast pumps that are designed for single users should never be rented or shared.

  20. Never use the breast pump while you are pregnant, as pumping can induce labor.

  21. The temperature of the portion of the device applied to the skin can reach temperatures as high as 43.9 “C. Excessively high temperatures may cause skin burns. Therefore, please ensure that the skin of your breast is intact and healthy before use. If you feel the device is overheating, please turn off the device. In order to avoid high-temperature burns, the maximum period of continuous use shall not exceed 30 min per instance, with at least 5 min intervals between uses to allow the device to cool down.

  22. For product service life (i.e. working life)
    The device has no shelf life but a product service life of one year. Please check to ensure the product operates normally prior to use. Use beyond the indicated service life may lead to degradation of product performance. For example. the product may not be able to correctly control the vacuum, resulting in excessive vacuum pressure which may cause injuries.

PRODUCT DESCRIPTION

Paruu R10 Wearable Breast Pump Hands Free Electric Portable Breast Pump User
Manual - Product Description

Parts

  1. Flange
  2. Linker
  3. Silicone diaphragm
  4. Pump motor
  5. USB Type-C cable
  6. Valve
  7. Milk collector

CONTROL PANEL

Paruu R10 Wearable Breast Pump Hands Free Electric Portable Breast Pump User
Manual - Control Panel Paruu R10 Wearable
Breast Pump Hands Free Electric Portable Breast Pump User Manual - Control
Panel

Note:
This product has a built-in lithium battery. When the battery indicator flashes, we recommend charging the pump motor promptly with the 5V=0.6A power adapter.

CLEANING AND DISINFECTION

Warning: Breast pumps are personal care items intended for a single user only and should never be rented or shared.

  1. Separate and wash all parts that come in contact with the breast and breast milk immediately after use, so as to avoid breast milk residue and prevent bacteria growth.
  2. Only use Potable water for cleaning.

⚠ WARNING

  1. The pump motor contains electronics that should be kept dry. Use a clean, damp cloth to clean the pump motor. Do not immerse the pump motor and USB charging cable in water.
  2. Please be careful when cleaning the valve. and silicone diaphragm, the machine will not work properly if one of the parts is broken.
  3. Clean the valve, do not rub it, do not insert anything, otherwise it may cause damage.

CHARGING

Paruu R10 Wearable Breast Pump Hands Free Electric Portable Breast Pump User
Manual - Charging

ASSEMBLY

Follow our step-by-step instructions to assemble the breast pump.

Paruu R10 Wearable Breast Pump Hands Free Electric Portable Breast Pump User
Manual - Assembly Paruu R10 Wearable Breast Pump Hands Free Electric Portable
Breast Pump User Manual - Assembly Paruu R10 Wearable Breast
Pump Hands Free Electric Portable Breast Pump User Manual -
Assembly

Caution:
Our products are packaged with a charging cable but not with a power adapter. Please purchase the power adapter by yourself before charging. Make sure the input power of the power adapter is AC 100~240V 50/60 Hz and the output power is DC 5V=0.6A.

PRODUCT SPECIFICATION

Paruu R10 Wearable Breast Pump Hands Free Electric Portable Breast Pump User
Manual - Product Specification

STORING YOUR BREAST MILK

Freshly expressed or pumped milk can be stored:

Paruu R10 Wearable Breast Pump Hands Free Electric Portable Breast Pump User
Manual - Storing your breast milk

These guidelines are for healthy full-term babies only and may vary for premature or sick babies. Check with your health care provider

Caution

  1. Use breast milk storage bags or clean, food-grade containers to store expressed breast milk. Make sure the containers are made of glass or plastic and have tightfitting lids, and label them with the date and time. Avoid bottles with the recycle symbol number 7, which indicates that the container may be made of BPA containing plastic.
  2. Refrigerate or freeze expressed milk immediately or keep it at a temperature of 16 °c ~ 25 °C for 2-4 hours before you feed your baby.
  3. Never refreeze breast milk after it has thawed. If your baby did not finest, the thawed breast milk, please throw it away instead of putting it back in the refrigerator or freezer.
  4. Please use a new bag to store freshly expressed breast milk, don’t mix fresh milk with older, previously cooled, or frozen milk.
  5. Store small amounts to avoid wasting milk that might not be finished. Store in 2 to 4 ounces or the amount offered at one feeding.

Note
Only store breast milk collected from a sterilized breast pump.

Thawing of breast mil

  1. Always thaw the oldest breast milk first. Remember first in, first out. Over time, the quality of breast milk can decrease.

  2. There are several ways to thaw your breast milk:
    · In the refrigerator overnight.
    · Set in a container of warm or lukewarm water.
    · Under lukewarm running water.

  3. Never thaw or heat breast milk in a microwave. Microwaving can destroy nutrients in breast milk and create hot spots, which can bum a baby’s moutti.

  4. If you thaw breast milk in the refrigerator, use it within 24 hours. Start counting the 24 hours when the breast milk is completely thawed, not from the time when you took it out of the freezer.

  5. Once breast milk is brought to room temperature or warmed, use it within 2 hours.

Warning

  1. Always check the temperature of your breast milk before feeding your baby.
  2. Do not heat the milk storage bottle by immersing it in boiling water to prevent it from cracking.

DECLARATION OF CONFORMITY

Hong Kong Lute Technology Co., Limited declares that the device conforms to the following standards
IEC60601-1. IEC60601-1-2. IEC60601-1 11. IEC62304.1S010993-5.1S010993-10. 1S010993-1, ISO 14971.

Disposal
This product bears the selective sorting symbol for Waste electrical and electronic equipment (WEEE). This means that this product must be handled pursuant to European directive 2O12/19/EU in order to be recycled or dismantled to minimize its impact on the environment. User has the choice to give his product to a competent recycling organization or to the retailer when he buys a new electrical or electronic equipment.

EMC GUIDANCE

Warning: Don’t use near active HF surgical equipment and the RF shielded room of an ME system for magnetic resonance imaging, where the intensity of EM disturbances is high.
Warning: Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are
operating normally.
Warning: Use of accessories, transducers, and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation.
Warning: Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 12 in (30 cm) to any part of the equipment, including cables specified by the manufacturer Otherwise, degradation of the performance of this equipment could result.

Paruu R10 Wearable Breast Pump Hands Free Electric Portable Breast Pump User
Manual - Guidance and Manufacture's Declaration Paruu R10 Wearable Breast Pump Hands Free Electric Portable Breast Pump User
Manual - Guidance and Manufacture's Declaration Paruu R10 Wearable Breast Pump Hands Free Electric Portable Breast Pump User
Manual - Guidance and Manufacture's Declaration

Note* -As an alternative to FM modulation, 50 % pulse modulation at 18 Hz may be used because while it does not represent actual modulation, it would be worst case.
Note** – The carrier shall be modulated using a 50 % duty cycle square wave signal.

GLOSSARY &SYMBOLS

Paruu R10 Wearable Breast Pump Hands Free Electric Portable Breast Pump User
Manual - Glossary & Symbols Paruu R10 Wearable
Breast Pump Hands Free Electric Portable Breast Pump User Manual - Glossary &
Symbols Paruu R10 Wearable Breast Pump Hands Free Electric Portable
Breast Pump User Manual - Glossary & Symbols

Manufactured for Hong Kong Lute Technology Co., Limited
Room 02, 21/F, Hip Kwan Commercial Building, 38 Pitt Street, Yau Ma Tei, Kowloon, Hongkong

US Importer: Company: PACIFIC FORTUNE MANAGEMENT INC
Address: 145 E Duarte RD Suite AA 198 Arcadia CA 91006
support@paruulife.com
MADE IN CHINA

FCC COMPLANCE
Note:
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Note:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and. if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals