The 207192 LI 40-10-390-450 I Light grids are a type of light grid system with evaluation electronics. They are designed for measuring and switching purposes. The system consists of a
transmitter, receiver, monitoring height, profile length, evaluation electronics, and profile cross section. The light grids have a compact design with an aluminum housing, making them easy to install. The light grids are available with different evaluation electronics options, including LVE, LVX, and LVB. They offer beam evaluation in horizontal or diagonal directions. The housing material is made of aluminum, and the protection class ensures durability and reliability.

Technical Data

  • Service voltage: (typ.)
  • Assembly: Profile cross section
  • Dimension: Profile length
  • Housing material: Aluminum
  • Protection class: (not specified)
  • Evaluation: Evaluation electronics
  • Output function: Switching output
  • Light source: (not specified)
  • Color: (not specified)
  • Wavelength: (not specified)
  • Beam evaluation: Horizontal or diagonal
  • Beam separation: (not specified)
  • Number of beams: (not specified)
  • Monitoring height: (not specified)
  • Range: (not specified)
  • Measuring range: (not specified)
  • Ambient temperature during operation: (not specified)
  • Protection type: (not specified)
  • Connection: (not specified)

Product Usage Instructions

  1. Unpack the light grid system and ensure all components are included (transmitter, receiver, monitoring height, profile length, evaluation electronics, and profile cross section).

  2. Identify the required evaluation electronics option (LVE, LVX, or LVB) based on your application needs.

  3. Choose the desired beam evaluation direction (horizontal or diagonal) for your specific application.

  4. Install the light grids by following the provided installation instructions. Ensure proper alignment and positioning between the transmitter and receiver.

  5. Connect the evaluation electronics to the light grids according to the specified connection instructions.

  6. Check the service voltage requirements and provide the necessary power supply.

  7. Configure the output function of the light grids based on your application requirements (switching output).

  8. If applicable, adjust the monitoring height and range settings according to your specific needs.

  9. Ensure that the ambient temperature during operation is within the specified range for optimal performance.

  10. Follow the recommended protection type guidelines to protect the light grids from external factors.

  11. If additional information or accessories are needed, refer to the provided link: https://www.di-soric.com/207192

    • With evaluation electronics LVE … / LVX … measuring and switching
    • With evaluation electronics LVB … switching
    • Beam evaluation horizontal or diagonal
    • Compact design
    • Aluminum housing
    • Easy to install
  12. Transmitter

  13. Receiver

  14. Monitoring height H

  15. Profile length L

  16. Evaluation electronics

  17. Profile cross section

To be used with evaluation electronics LVE …/ LVX ../ LVB …

  • di-soric -LI -40-10-390-450 -I -Light -Curtains -Grids -fig \(2\) BN: brown
  • GN: green
  • GY: grey
  • WH: white
  • YE: yellow

di-soric -LI -40-10-390-450 -I -Light -Curtains -Grids -fig
\(3\)

Technical data (typ.)

  • Service voltage     20 … 26 V DC (see evaluation electronics)
  • Assembly     Threaded bolt (2)
  • Profile cross section  12 x 24 mm
  • Dimension
    • A: 75 mm
    • B: 300 mm
    • X: 13,5 mm
    • Y: 38,5 mm
  • Profile length    450 mm
  • Housing material   Aluminum (natural)
  • Protection class    III, operation on protective low voltage
  • Evaluation    absolute, percentage, Configurable via evaluation electronics
  • Evaluation electronics      external
  • Output function        Configurable via evaluation electronics
  • Switching output     Configurable via evaluation electronics, NO, NC
  • Light source             LED
  • Color                        Infrared
  • Wavelength           880 nm
  • Beam evaluation  via external evaluation electronics
  • Beam separation    10 mm
  • Number of beams  40
  • Monitoring height  390 mm
  • Range            250 … 6.000 mm (adjustable via evaluation electronics)
  • Measuring range  390 mm
  • Ambient temperature during operation   -20 … +40 °C
  • Protection type   IP 54 (IP 65 optional)
  • Connection    Cable, 4,0 m (with plug connector, additional variants on request)

More information / accessories https://www.di-soric.com/207192
di-soric GmbH & Co. KG . Steinbeisstraße 6 . DE-73660 Urbach . www.di- soric.com
© di-soric . Right to change reserved . 13.08.2022 .

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals