Product Information
- Product Name: USGT 40/13 IU-B4
- Model Number: 213498
- Function: IND. CONT. EQ. 29W7
- Enclosure Type: 1
- Supply Class: 2
- NFPA 79 Applications only. For adapters providing field wiring means refer to product information or customer support.
- Operating Principle: Fork opening
- Measuring Range: +/- 0.1 mm to 30 mm
- Reproducibility: 6 x
- Service Voltage: Not specified
- Analog Output Voltage: Not specified
- Analog Output Current: Not specified
- Ambient Temperature during Operation: Not specified
- Protection Type: IP 67
- Safety Instructions: Not a safety component pursuant to 2006/42/EG and EN 61496-1/-2! May not be used for personal protection! Non-compliance can lead to death or serious injuries! Only use as directed!
Product Usage Instructions
- Detecting an object:
- Insert the object to be detected.
- Press button A until all three LEDs are shining.
- Removing the object from the detection area:
- Remove the object from the detection area.
- Press button B until all three LEDs are shining.
- Teach process:
- The teach process is completed successfully if the voltage output is 0 V when an object is inserted.
- Inverting the signal:
- Press buttons A and B at the same time for 5 seconds until the LED for A (yellow) lights up.
- Release buttons A and B.
- Acknowledgment is signalled by all 3 LEDs flashing (6 times).
- Resetting to factory setting:
- Press buttons A and B at the same time for 10 seconds until the LED (green) lights up.
- Release buttons A and B.
- Acknowledgement is signalled by all 3 LEDs flashing (6 times).
- Button lock:
- Press buttons A and B at the same time for 15 seconds until the LED for B (yellow) lights up.
- Release buttons A and B.
- Acknowledgement is signalled by all 3 LEDs flashing (6 times).
- The buttons are unlocked in the same way.
- Change of the output function U/I:
- Press buttons A and B at the same time for 20 seconds until all 3 LEDs light up.
- Release buttons A and B.
- Acknowledgement is signaled by all 3 LEDs flashing (6 times).
- Reset the analog output to U (factory setting) in the same way.
Safety instructions
General safety notice
WARNING! Not a safety component pursuant to 2006/42/EG and EN 61496-1/-2!
May not be used for personal protection! Non-compliance can lead to death or
serious injuries! Only use as directed!
DIMENSION
- Teach dampened
- Teach undampened
- Radial run-out +/- 0.1 mm within 30 mm
Wiring
Technical data
Operating principle +20°C, 24 V DC
Fork opening
Ultrasonic through- beam sensor
Measuring range
40 mm
Reproducibility
13 mm (typ.)
Service voltage
± 0,1 mm
Analog output voltage
12 … 30 V DC
Analog output current
0 … 10 V
Ambient temperature during operation
4 … 20 mA
Protection type
0 … +60 °C
Function
How to use
Detecting an object:
Insert object to be detected:
Press button A until all three LEDs are shining.
Remove object from detection area.
Press button B until all three LEDs are shining.
The teach process is completed successfully if the voltage output is 0 V when an object is inserted.
|
---|---
|
Inverting the signal:
Press buttons A and B at the same time for 5 seconds until the LED for A (yellow) lights up. Release buttons A and B. Acknowledgement is signalled by all 3 LEDs flashing (6 times).
|
Resetting to factory setting:
Press buttons A and B at the same time for 10 seconds until the LED (green) lights up. Release buttons A and B. Acknowledgement is signalled by all 3 LEDs flashing (6 times).
|
Button lock:
Press buttons A and B at the same time for 15 seconds until the LED for B (yellow) lights up. Release buttons A and B. Acknowledgement is signalled by all 3 LEDs flashing (6 times).
The buttons are unlocked in the same way.
|
Change of the output function U/I:
„Press buttons A and B at the same time for 20 seconds until all 3 LEDs light up. Release buttons A and B. Acknowledgement is signaled by all 3 LEDs flashing (6 times).
Reset the analog output to U (factory setting) in the same way.“
|