LI 272-5-1355-1390 T
Light grids

  • With evaluation electronics LVE … / LVX … measuring and switching
  • With evaluation electronics LVB … switching
  • Beam evaluation horizontal or diagonal
  • Compact design
  • Aluminum housing
  • Easy to install
  1. Transmitter
  2. Receiver
  3. Monitoring height HO
  4. Profile length L
  5. Evaluation electronics
  6. Profile cross section

Function

Technical data

Technical data (typ.)                               +20°C, 24 V DC

  • Service voltage                                          20 … 26 V DC (see evaluation electronics)
  • Profile cross section                                        12 x 58 mm
  • Dimension
    • X: 17,5 mm
    • Y: 17,5 mm
  • Profile length                                                       1.390 mm
  • Housing material                                        Aluminum (natural)
  • Protection class                                        III, operation on protective low voltage
  • Evaluation                                                    absolute, percentage, Configurable via evaluation electronics
  • Evaluation electronics                                        external
  • Output function                                        Configurable via evaluation electronics
  • Switching output                                     Configurable via evaluation electronics, NO, NC
  • Light source                                                  LED
  • Color                                                              Infrared
  • Wavelength                                                  880 nm
  • Beam evaluation                                           via external evaluation electronics
  • Beam separation                                           5 mm
  • Number of beams                                           272
  • Monitoring height                                           1.355 mm
  • Range                                                                 250 … 6.000 mm (adjustable via evaluation electronics)
  • Measuring range                                           1.355 mm
  • Ambient temperature during operation   -20 … +40 °C
  • Protection type **** IP 54 (IP 65 optional)
  • Connection                                               Cable, 4,0 m (with plug connector, additional variants on request)
  • More information / accessories                             https://www.di-soric.com/206760