mr steam MS90EC1 Residential 100 cu ft Steam Shower Instruction Manual
- June 13, 2024
- Mr.Steam
Table of Contents
mr steam MS90EC1 Residential 100 cu ft Steam Shower
Product Information
The SteamLinx Module and Mobile App allow for seamless control of time and temperature using your smartphone or mobile device. It is compatible with all MrSteam controls for MS generators SN 1174000 and up. The SteamLinx hardware is required for control with the SteamLinx Skill for Alexa. These installation instructions contain safety alert symbols and panels, which identify potential safety hazards and provide important information for the installation and use of SteamLinx. It is recommended to read the Installation, Operation, and Maintenance Manual for Steambath Generator Systems (PUR100472) before installing SteamLinx to ensure the safety and proper installation of the steam generator.
Product Usage Instructions
Connecting SteamLinx A to the Steam Generator
To prevent shock hazards, disconnect the power at the breaker box before
removing the generator cover. It is important to note that MrSteam steam
generators are connected to 240V line voltage and contain live electrical
components. Therefore, all installation and service must be performed by a
licensed and qualified electrician.
Steps:
-
Remove the circuit board cover screws and generator cover.
-
Locate the knock-out in the generator jacket.
-
Connect SteamLinx A to the steam generator using the provided instructions.
-
Connecting SteamLinx B to the Home Router
Steps:- Locate an ethernet slot on the back of the home router.
- Connect SteamLinx B to the home router using an ethernet cable (3′).
-
Connect the power supply to a 120V outlet.
Connecting SteamLinx to the Internet
This step assumes that SteamLinx A and B are already connected as described in the previous steps.
Steps:- Follow the provided instructions to connect SteamLinx to the internet.
Troubleshooting: Blinking LED
If the units are out of range or not paired, follow these troubleshooting steps:
- Check the indicator lights LEDs.
- If the yellow LED is blinking, the units are in pairing mode.
- If the red LED is on, there might be a problem with the connections, router configuration, or steam generator circuit board.
- If the green LED is on, SteamLinx B is detected but not connecting to the internet.
- If the blue LED is on, the units are connected correctly.
PUR 100518 1.21
INSTALLATION INSTRUCTIONS
SteamLinx Module and Mobile App allow for seamless control of time and
temperature using your smartphone or mobile device. SteamLinx hardware is
required for control with the SteamLinx Skill for Alexa. SteamLinx works with
all MrSteam controls (for MS generators SN 1174000 and up). These instructions
contain safety alert symbols and panels. These alert symbols and panels
identify potential safety hazards and provide important information for the
installation and use of SteamLinx. Read the Installation, Operation, and
Maintenance Manual for Steambath Generator Systems (PUR100472) before
installation of SteamLinx to ensure safety and proper installation of the
steam Generator.
All drawings for schematic purposes only.
WARNING
Indicates a potentially hazardous situation, which, if not avoided, may
result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation, which, if not avoided, may
result in minor or moderate injury or product damage.
NOTICE
is used to address practices not related to physical injury.
Notice alert SteamLinx A and B signal range is limited max. distance of 60ft.
Connecting SteamLinx A to the Steam Generator
-
Disconnect power to the generator at the breaker box.
-
Locate the SteamLinx A (with the integral cable)
WARNING
To prevent shock hazards, disconnect the power at the breaker box before removing the generator cover -
Remove knock-out.
-
Remove the generator cover.
-
Route the SteamLinx A cable through the knockout
WARNING
ELECTRICAL SHOCK HAZARD. MrSteam steam generators are connected to 240V line voltage and contain live electrical components. All installation and service must be performed by a licensed and qualified electrician. -
Locate the circuit board.
-
Plug the SteamLinx A into the white connector located at the far left side of the circuit board.
-
Replace the cover and screws.
-
Restore power.
WARNING
ELECTRICAL SHOCK HAZARD. MrSteam steam generators are connected to 240V line voltage and contain live electrical components. All installation and service must be performed by a licensed and qualified electrician.
Connecting SteamLinx B to the Home Router
- Plug the blue ethernet cable provided, into an ethernet slot on the back of the home router.
- Plug the power supply into a 120V outlet.
Connecting SteamLinx to the Internet
- Ensure the mobile device is on the WiFi network.
- Download the SteamLinx App from the Apple Store or Google Play by following the prompts.
- Enable the SteamLinx Skill for Alexa through your Alexa App.
Troubleshooting
Blinking LED Units are out of range or not paired
- Turn the breaker off.
- Ensure SteamLinx A is connected to the steam generator.
- Use a paperclip or similar blunt end object to press the reset button (above the LED) on SteamLinx B.
- The LED will flash yellow (it stays in pairing mode until it is paired or powered off).
- Turn the breaker to the steam generator ON, if the two transmitters are functioning correctly and within range the LEDs will turn blue.
- If the Blue, Green or Red LEDs are blinking the units are not pairing because they are out of range. Using an extension cord for power, move the SteamLinx B closer to SteamLinx A. Disconnect the ethernet cable (the router connection is not required for this test). If the LEDs stop blinking this confirms the units were out of range.
Indicator Lights LEDs
- Yellow Blinking units are in pairing mode.
- Red Router not detected: problem with connections, router configuration or steam generator circuit board.
- Green SteamLinx B: The router is detected but is not connecting to the internet.
- Blue Units are connected correctly.