DIVERSITECH CP-M115 Condensate Pump for Ductless Mini Splits Owner’s Manual
- June 13, 2024
- DIVERSITECH
Table of Contents
DIVERSITECH CP-M115 Condensate Pump for Ductless Mini Splits
Product Information
The Condensate Pump Ductless is a nonsubmersible pump designed for standard applications. It is available in two models: CP-M115 and CP-M230. The pump has a power supply consumption of 19W and operates at different voltage and frequency levels depending on the model. It has a liquid capacity of 4 gallons per hour (GPH) at zero head and 1.3 GPH at 20 ft head. The maximum discharge and suction distances are specified in the flow rate chart. The pump is equipped with thermal protection and has a noise level of less than 21 dBA at a distance of 3.3 ft. It meets the Ingress Protection standards and is suitable for indoor use only.
Product Usage Instructions
- Disconnect power before installation and ensure the pump is not installed in zones of air circulation.
- Install the reservoir tank and pump module as shown in Figure A.
- Use the supplied cables for installation and ensure the discharge tube of the pump module is higher than the tank reservoir.
- Connect the 1/4 discharge tube to the 0.16 x 0.25 reducer (supplied).
- Ensure all electrical components are installed above the top-grade level of the pump to reduce the risk of electric shock.
- Connect the alarm consisting of Common(C)/Orange, Normally open(NO)/Purple, and Normally closed(NC)/Grey wires as per the wiring diagram.
- Use the normally open (NO) connection to activate an audible or light alarm for potential overflow and use the normally closed (NC) connection to shut off unit power and prevent further condensate generation.
- Ensure proper maintenance by rinsing the heat exchanger and water tank of the air conditioner with water.
- Position the tank reservoir in an acceptable position and ensure the vent tube is positioned upward with the black cap fitted on the unused outlet.
- Tighten clamps and ensure the float magnet is positioned upward.
- Ensure the pump is not run without water to avoid damage or decreased performance.
For any warranty-related inquiries, please contact DiversiTech Corporation at 800.995.2222.
Standard Applications
Models : CP-M115, CP-M230
Installation Instructions
Description
Due to its small size, the Asurity™ Mini-Split Pump is easy to use in all
ductless systems (ceiling, wall or floor-standing) with a cooling capacity of
36,000 BTU/h or less. The Mini-Split Pump comes in two modules:
- Pump module (pump + control circuits)
- Tank reservoir (three-level float: Pump shut-down, Pump start-up, and alarm)
Technical Data
Liquid Type: | Condensate water from mini-split system – maximum 35°C/95°F |
---|---|
Power Supply | CP-M115: 115V 60 Hz |
CP-M230: 230V 50/60 Hz | |
Consumption | 19 W |
Rating | 70% duty cycle (ex: 7 sec.ON/3 sec. OFF) |
Working Temperature | 41°F to 113°F – 5°C to 45°C |
Storage Temperature | 37°F to 158°F – 3°C to 70°C |
Class | Class 1 appliance |
Capacity | 4 GPH @ zero head, 1.3 GPH @ 20 ft head |
Maximum Discharge | See Flow Rate Chart |
Maximum Suction | 6.6 ft |
Thermal Protection | Yes – with auto-restart |
Ingress Protection | IP64 |
Noise Level | < 21 dBA* at 3.3 ft distance |
*= Average level pressure at 3.3 ft, calculated on acoustic power level Lwad = 32.80 dBA (ref 1pw) NF EN Iso 3744 standards
Installation
This pump must not be installed in zones of air circulation.
- Disconnect power before installation. Only use the supplied cables.
Installation of the Pump Module
- Disconnect the power supply before installation. The pump module may be installed in the mini-split unit, in a line set cover like SpeediChannelTM (See Figure A) or in a false ceiling. Double-sided adhesive foam tape
is provided for that purpose. A space must be left around the pump module for it to cool in the event of prolonged operation. The pump module should not be insulated. The discharge tube must have an inside diameter of 1/4” and be used with the 0.16” x 0.25” reducer (supplied). Use the included cable ties to properly secure the discharge hose to the pump. Make sure to observe the flow direction indicated by the arrow on the pump module. White/Neutral, Black/Line, Green/Ground.
WARNING : Nonsubmersible Pump
- The discharge tube of the pump module must always be higher than the tank reservoir and must have an inside diameter of 1/4” in order to prevent siphoning. Connect the 1/4” discharge tube to the 0.16” x 0.25” reducer (supplied).
- Risk of Electric Shock – This pump has not been tested for use in swimming pools or marine applications.
- To reduce the risk of electric shock, install all electrical components above the top-grade level of the pump. This pump is not submersible. For indoor use only.
Alarm
- Consisting of: Common(C)/Orange, Normally open(NO)/Purple and, Normally closed(NC)/Grey. The switch is rated to 5A max. Use normally open (NO) to activate audible or light alarm to signal potential overflow. Use normally closed (NC) to shut off unit power to prevent further condensate generation.
CONNECTION OF THE OVERFLOW SWITCH IS MANDATORY. FAILURE TO DO SO WILL INVALIDATE THE MANUFACTURER’S WARRANTY AND MAY INDUCE FLOODING AND WATER DAMAGE. ALSO, NOTE THAT THE OVERFLOW SWITCH IS ELECTRONIC AND DRAWS ITS POWER DIRECTLY FROM THE PUMP, SO THE SWITCH ITSELF CAN OPERATE UNLESS THE PUMP IS POWERED.
Installation of the Tank Reservoir
- The tank reservoir must be connected to the pump using the supplied four-conductor cable and connectors. The supplied flexible elbow may be used to connect the inlet of the tank reservoir to the air conditioner condensate tray. Connect the supplied 6.6 ft long flexible tubing (0.2” ID) to one of the tank reservoir outlets. Ensure the black cap is installed on the unused tank outlet. Connect the supplied 6” long vent tubing (0.16” ID) to the vent port on the tank reservoir lid. Extend the vent tube upwards, ensuring that it maintains a position above the level of the tank.
The tank reservoir must be installed and fastened in a horizontal position with the mounting clip (supplied) in a dry location. Choose the most appropriate place and plug the outlet not being used with the black cap.
- Before plugging the connectors, check they are clean, dry, and not live
- Connect the four-conductor plug and receptacle while aligning the arrows
Operation
Ensure that the tank is installed so that the alarm will activate before the condensate tray overflows (the top of the tank is below the rim of the condensate tray). Before finishing the installation, it is recommended that you test the correct operation of the condensate removal pump.
- Never try to run the pump “dry” without water (may damage the pump)
- Rinse the condensate water tray thoroughly to eliminate all metallic particles and foreign bodies
- Ensure that the reservoir tank is connected to the condensate tray to collect the condensate from the mini-split unit
- Pour water into the condensate tray of the air conditioner
- Check to ensure the pump starts, pumps water, then stops
- Test the alarm by pouring water in at a rate faster than the pump discharge until the float activates the pump alarm
Maintenance
Any maintenance on the condensate pump MUST BE DONE WITH THE POWER SUPPLY
SWITCHED OFF. At the beginning of the season, or regularly if the mini-split
unit is used all year long:
Remove the cap of the tank reservoir, the filter and the magnet. Clean inside
the tank reservoir and the float with water containing 5% bleach. Ensure that
the rubber seal is installed and seated properly in the tank lid, install the
float with the magnet facing upward, and replace the filter. Replace the tank
lid and do a full operational test.
Safety
- Asurity™ strongly recommends connecting the high-level alarm cable to a light or audible alarm
- The pump module features a thermal cut-out set at 70°C with AUTO-RESET
- Ensure that the ground wire of the pump is connected properly
- Conforms to UL STD 778 certified to CAN/CSA STD C22.2 NO. 108 Recognized ETL
Mini-Split Pump Recommendations
-
Please read the instructions carefully.
-
Rinse the heat exchanger, and water tank of the air conditioner with water.
-
Acceptable positions for tank reservoir.
-
Position the vent tube upward.
-
Tighten clamps.
-
Position the float magnet upward.
-
Alarm connection: See wiring diagram. Breaking capacity: 5A Max. (resistive load) Mains 110-120V – 60 Hz or 220-240V – 50/60Hz
CAUTION! Never run the pump without water. This can destroy or decrease the pump performance. -
Negative discharge is not allowed.
Warranty
All pumps manufactured by or for DiversiTech Corporation (the Company) and
sold by the Company under the Asurity™ and DiversiTech brand are warranted to
be free of defects in workmanship and materials for a period of 24 months from
date of sale from the distributor to the contractor. The Company will credit,
repair or replace, at its option, any pump if deemed defective within this
time period. All products returned to the Company must include a return
authorization issued by the Company. The returned product should be suitably
packaged and shipped prepaid from the point of shipment to the point
designated in the Company’s return authorization. This warranty is a limited
warranty and shall be in lieu of any other warranties, expressed or implied,
including, but not limited to, any implied warranty of merchantability or
fitness for a particular purpose. There are no other warranties that extend
beyond the description of the face hereof. The liability of the Company
arising out of its supply of said products, or their use shall not in any case
exceed the cost of correcting defects in the products as set forth above. The
Company shall not be liable for any costs or damage incurred by its customers
in the removal or replacement of defective products from units in which the
products have been assembled. In no event shall the Company be liable for loss
of profits, indirect, consequential, or incidental damages.
AsurityTM is a registered trademark of DiversiTech Corporation
©2021 DiversiTech Corporation