genie GIP57S-U 2MP IP 18x PTZ with Starlight and PoE User Manual
- June 13, 2024
- GENIE
Table of Contents
genie GIP57S-U 2MP IP 18x PTZ with Starlight and PoE
Please read these instructions carefully before operating the unit and keep for further reference.
Special Declaration
Before connecting and using this product, please read these instructions
carefully and keep it for references in the future.
This manual might be not accurate technically or contains some minor type
errors. The contents in this manual about production description and program
might be updated without notice. Updated contents will be added in the new
version. We will change or upgrade the products or program any time.
CAUTION
Careful Transport
During transport, custody and installation should prevent damage to this
product by weight, severe vibration and soak.
Power Supply, Video Cable and Control Cable
For power supply cable, video cable and control cable, please adopt shielded
cable and independent wiring, can not mix with other cables.
Electric Safety
Should obey all kinds of electric standard when using speed dome camera, make
sure signal cable keep enough distance (at least 50m) with high voltage
equipment or cables. If it is possible, please take lightning and surge
protection measures.
Clean
When clean camera housing, please use dry soft cloth to wipe, If it is very
dirty , please use neutral cleanser to wipe lightly. Do not use strong or
grind cleanser to prevent its housing from scratching.
Strictly Sealed
Prevent liquid or other things from getting into speed dome housing, else it
will cause permanent damage.
Please do not use camera beyond limited temperature and humidity
Speed dome camera working temperature:-25℃ to 50℃, humidity less than 90%.
Please do not install camera near air conditioner ’s outlet
- Under following situation, lens will be fogged because of condensation.
- Use under the environment where the temperature rise and down frequently which caused by the air conditioner power on and of f frequently.
- Use under environment which can make glass fog.
- Use under environment full with smoke or dust.
Please do not make camera toward to strong light source, such as the sun
Toward camera to strong light source for a long time will damage the color filter on CCD, then it will make image lose color.
Product Overview
Product Features
Stronger Intelligent Function
- Support WEB access to visit and configure the devices, support OSD, support real time video transmission, support motion detection.
- Built in network code function, support ONVIF protocol.
- Support JPEG capture picture, unified client remote control monitoring software and easy connect the brand NVR.
- 10/100M auto adaptive, support RTSP/ FTP/PPPOE/DHCP/DDNS/NTPS and so on network protocol.
PTZ Control
- Pan 360 °, continuous rotation; Tilt 90°, no monitoring blind spot.
- Auto adjust PTZ speed according to the zoom function.
Night vision
- Auto open infrared lamps according to the light.
- Auto adjust the brightness of infrared lamps based on the lens far or near.
- Adopt the forth infrared array light technology coordinate with intelligent dimming technology, better night vision.
Speed Dome Parameter
Electric
Rated voltage| DC12V 2A ±10%| Power Consumption| Max 20W
Decoder| Built in| IR distance| 40m~60m
Operate
Pan Range| 360°endless| Tilt rotate| 90°
High Speed| Pan 0.6°~ 200°/s Tilt: 0.8°~ 75°/s| Preset| 220
Middle Speed| Pan 6°~ 30°/s Tilt: 5°~ 17°/s| Monitoring Method|
Preset/Patrol/Pan Scan
10/100M auto adaptive; support RTSP/FTP/PPPPOE/DHCP/DDNS/NTP/UPnP and so on
network protocol, support WEB,support OSD, support real time video
transmission, support motion detection, support JPEG capture picture; support
unified client remote control monitoring software, easy connect brand NVR in
the market.
Environment
Operate Environment| Outdoor:-20 ~ +60℃ Indoor: -10 ~ +50℃| Protection Grade|
IP66(outdoor speed dome camera)
Environment Humidity| 0~95% no condensation
Physical
Installation Method| Wall Mount or Ceiling Mount
Structure Dimension
Speed Dome Camera
Speed Dome Camera Brackets
Wall Bracket
Ceiling Bracket
Installation
Installation Instruction
Prepare before installation
Installation under professional technician and obey related rules in order to
avoid troubles.
Confirm all accessories complete or not, make sure the speed dome camera
application place and installation method meet the requirement.
Wall mount/ceiling mount speed dome camera composed by bracket, zoom module
and transparent cover and other parts.
Speed dome camera has been finished the installation test when export, user
can do installation directly.
Installation Method
Step 1 – Draw positioning holes Take out bracket from package box, mark
the hole’s position on wall or ceiling based on mount bracket bottom 4pcs
installation holes.
Step 2- Drill holes and put expansion screws in Drill 4pcs expansion
screw’s installation holes at pre-marked position, then put 4pcs expansion
screws in. Note: Please bring expansion screws own.
Step 3- Please unscrew the two screws on the transparent DIP switch
cover.
Use screwdriver open the 2 screw which used to fix the transparent DIP switch
cover as above picture.
Step-4: Please refer to the third section of this chapter- Baud rate
setup.
Step-5: Install the transparent DIP switch cover. Please put the 2 holes
of the transparent DIP switch cover focus to the two screw hole of the speed
dome cover, then use screwdriver to install that 2 screws.
Step 6 : Lead cable through bracket
Step 7: Ceiling mount connect speed dome and bracket. Put the connection
port of the speed dome into bracket hole and put the screw lock into
corresponding threaded holes.
Step 8: Fix the speed dome camera.
Lead cable drawn out from the holder recess, then put the 4 installation hole
of bracket of speed dome focus on the wall / ceiling’s 4pcs expansion screw
and tighten that 4pcs nut. Then seal the appeared groove via glass glue.
Step 9: Cable connecting Please refer to the Section VI of this chapter-
Connecting Method.
Step 10: Tear off protection film Teal off protection film of transparent
cover.
Note: please take care of transparent cover.
Baud Rate Setup
Baud rate and corresponding DIP status as bellow:
Baud Rate
RS485 control bus need all device which connect to it shall be in parallel mode, and each end of the system shall be connected to a 120Ω resistor. Our speed dome has a 120Ω resistor in it, you need only set it up through dip switch SW2, put the 4th switch on, then the resistor is connected, details as below:
ID Setup
ID setup (address code setup obey binary rules) address code shall be set
through 8 DIP switch (SW1).
Keyboard control speed dome through communication bus, one keyboard can
control max. 255pcs speed dome camera, each speed dome camera has its own
address code, user can set address code through 8 DIP switch, details as
bellow:
Address | SW1 Switch Setup |
---|---|
SW1-1 | SW1-2 |
1 | ON |
2 | OFF |
3 | ON |
4 | OFF |
5 | ON |
6 | OFF |
7 | ON |
8 | OFF |
9 | ON |
10 | OFF |
11 | ON |
12 | OFF |
– – – | – – – |
254 | OFF |
255 | ON |
Power supply and network cable connection
Power supply connection
Note: Please carefully check the rated voltage and power supply, rated
voltage and current as below:
Rated Voltage | Rated Voltage Range | Current |
---|---|---|
DC12V | ±10% | 2A |
Network connection
Network speed dome camera can connect with computer, NVR monitoring device
through router or switch or other network devices by network parallel cable;
also can connect with computer, NVR by network crossover cable.
Note:1) Network cable output distance less than 100m.
2) Network parallel and network crossover connection method details
please refer to appendix-Network cable connection method.
3) IP address of speed dome camera in Monitoring network should not be
the same.
Connection Method
Connection method as below program, order to connect network cable, power supply cable(connect order based on the keyboard model number, here just give one example). Details as below:
Connection Diagram Instructions
Port Mark | Port Instruction | Connection Instruction |
---|---|---|
Power Supply Cable | DC12V Power Input | Connect DC12V/4A Power Supply |
1: TX+ | ||
Network Port | Connect Network | 2: TX- |
3: RX+
| | 6: RX-
Typical Wiring Diagram
LAN Connection
WAN Connection
Basic Operation
The operation methods of different system platforms are not completely same. Generally, it is subject to the user manual provided by the manufacturer. There will be specific requirements and operation methods in different conditions. Please contact the supplier for required information.
Power-On Self Test
When the power is on, camera will pan / tilt rotate automatically, which is to make sure camera works well by self test. Configuration of the IP camera can be done by Web, Client or NVR(Please find the details in CD, << Client User Manual>> ). Pan / Tilt rotation, presets call, and specific functions can be controlled by PTZ control interface.
Preset Setting
Following is the steps:
(1) Adjust to picture of camera through PTZ control interface.
(2) Choose preset number in control interface, click “Add”, camera saves
the parameters of preset scenario.
Preset Call
Following is the steps:
(1) Choose preset number in control interface, click call;
(2) Camera moves to preset position immediately, the zoom of lens will
change to preset parameter automatically.
Function Realization By Preset
Adopting the method of double-layer presets, achieve all the functions of the camera by preset call, Specific correspond <> and <>. Call mode: call mode is on in general preset of call, specific function is achieved by the mode of preset call; for example: [92] + [SHOT] + [1] + [SHOT], which is to call patrol 1; Setting mode: setting mode is on in general preset of setting, specific function is achieved by the mode of preset call; for example: [92] + [PRESET] + [1] + [SHOT], which is to set patrol 1.
Preset Function Table of General Function
General Function | Preset | Remarks |
---|---|---|
IR | 90 | |
Zoom module | 91 | |
Patrol scan | 92 | |
Pattern scan | 93 | |
PTZ control | 94 | |
Menu | 95 | Support dome menu |
System Setting | 96 | |
Reservation | 97 | |
High speed auto scan | 98 | |
Low speed auto scan | 99 |
Preset Function Of Specific Function
General Function| Preset No.| Call Mode| Setting Mode|
Remarks
---|---|---|---|---
IR Function only support IRspeed dome camera| 1| Auto ON/OFF|
|
2| Forced ON| |
3| Force OFF| |
11| High Sensitivity| |
12| Middle Sensitivity| |
13| Low Sensitivity| |
| **| IRCUT-ON| |
**| IRCUT-OFF| |
**| IRCUT -AUTO ON| |
**| IRCUT-AUTO OFF| |
**| Zoom Camera
Automatic Diagnosis| |
**| SONY| |
52| HITACHI| |
53| SAMSUNG| |
54| HIK| |
55| MYTECH| |
56| LG| |
57| LG-XDI| |
58| CNB| |
59| CNB 36 x Optical Zoom| |
PTZ Control| 1-8| Park preset 1-8| |
| 9-16| Park patrol 1-8| |
| 17-20| Park pattern 1-4| |
| 21| Park auto scan| |
| 22| Park AB lines scan| |
| 30| Park time 0(off)| |
| 31| Park time 1 Os| |
| 32| Park time 30s| |
| 33| Park time 60s| |
| 41| A line-scan setting| |
| 42| Bline-scan setting| |
| 43| High speed line-scan start| |
| 44| Middle speed
line-scan start| |
| 45| Low speed
line-scan start| |
| 46| Inner arc line-scan| |
| 47| Outer arc line-scan| |
| 50| Open autotracking| |
| 51| Off autotracking| |
| 52| Off zoom self-adaption| | support speed
dome camera with autotracking
| 53| Open zoom self-adaption| | support IP
speed dome camera with autotracking
| Continuous call 10,12,14| Restore factory settings| |
System Setting| 30| On/off Auto-flip| | Support flip
Dome Camera
Patrol Setting
Start patrol order “set preset 92+ call corresponding preset of patrol
number”,then add preset “call preset”, every patrol path can add Max. 32
presets. After adding, save the setting by “set preset 92 + call preset 9” The
setting of preset standing time: “set preset 92 + call preset 10 + call
corresponding preset of time”.
The setting of preset running speed in patrol: “set preset 92 + call preset 11
- call corresponding preset of speed;
[For example] add 1-4 presets in patrol 1, standing time 30s, speed 40, follow the instructions below:
Add preset in patrol path:
(1) Set preset 92, call preset 1, start patrol 1 setting.
(2) Call preset 1, add preset 1 to patrol 1.
(3) Call preset 2, add preset 2 to patrol 1.
(4) Call preset 3, add preset 3 to patrol 1.
(5) Call preset 4, add preset 4 to patrol 1.
(6) Call preset 92, then call preset 9, save patrol 1.
The setting of preset standing time in patrol:
(1) Set preset 92,then call preset 10,start the setting of preset
standing time.
(2) Call preset 30, set standing time to 30s. The setting of preset
running speed in patrol:
(1) Set preset 92,then call preset 11,start the setting of preset running
speed.
(2) Call preset 40, set preset running time to 40.
Simple Troubleshooting
Failure Mode | Parts For Checking | Possible Cause | Solution |
---|---|---|---|
No actions and no images after power on | External electricity | Power supply is | |
abnormal | Replace | ||
Main board exists problems | Replace | ||
There is image, but camera can’t self test after power on | Motor is abnormal | ||
Mechanical fault | Whether something get stuck | ||
The swing of camera | Very oblique | Adjust | |
Power is not enough | Use the right power supply | ||
Main board exists problems | Replace | ||
Camera can self test after power on, but no image | No connect cable between | ||
power board and connecting plate | Disconnected | Connect again | |
Network cable | Disconnected | Connect well | |
Cable is too long | The normal length is 100m | ||
IP addresses conflict | Change IP address | ||
Line-sequential of network cable is wrong | Equivalent devices use crossover |
cable; Incoordinate devices use parallel cable
There is image, camera can self test after power on, but can’t control|
Client, Web configuration| The settings of PTZ address, protocols, and baud
rate| PTZ address, protocols, and baud rate must correspond with the
information of camera dial code
Image is faint| | Camera is in the status of manual focus| Set the zoom module
to auto focus
Transparent protective cover| It is dirty| Clean the cover
Clean The Transparent Cover
The transparent cover must be cleaned regularly to make imaging clear.
Please be careful when you clean it. Don’t touch the transparent cover
directly; the acidic perspiration stains may corrode the surface coating of
this transparent cover. Hard objects may scratch the transparent cover, which
will lead to faint imaging.
Please use soft dry cloth or other substitutes to clean it.
If dirty is serious, you can use neutral cleanser. It also can be cleaned by
any senior furniture cleaning products.
Appendix
Lighting Protection, Surge Protection
- Outdoor speed dome camera must consider thunder-proof and surge immunity. On the premise of guaranteeing electrical safety, we can take following lightning protection measures: At least keep 50m distance between signal transmission line and high voltage equipment or high voltage cable.
- Outdoor wiring under the eaves.
- For open field, adopt seal steel pipe buried wiring way, and adopt one-point earthing with the steel pipe. Do not adopt aerial wiring.
- It need to add extra high-frequency thunder-proof device and lightning rod in strong thunderstorms area or high inductive voltage region(such as high voltage substation).
- Thunder-proof and grounding design of Exterior installation and circuit must be in accordance with building lightning proof requirements; It must meet national standard and industry standard.
- System must be equipotential grounding. Grounding device must meet anti- jamming and electric safety dual requirements. The connection with strong electrified wire netting can’t be short connection or mixed connection. When system is in the condition of single-phase grounding, ground impedance is less than 4Ω, ground wire cross-section area must be more than 25 mm.
Pressing Line Method And Line-sequential Of Network Cable
There are two kinds of network cable: crossover cable and parallel cable.
Crossover cable: one end uses the standard of 568A, the other end uses the
standard of 568B.
Parallel cable: Both the two ends use 568A or 568B (568B is mostly adopted).
The standard of 568A: green-and-white, green, orange-and-white, blue, blue-
and-white, orange, brown-and-white, brown.
The standard of 568B: orange-and-white, orange, green-and-white, blue, blue-
and-white, green, brown-and-white, brown.
If the two equipments are incoordinate, use parallel cable to connect. For
example, connect PC to the router or switch.
If the two equipments are equivalent, use crossover cable to connect. For
example, connect PC to PC.
Customer Service
Sales +44(0)1707 330541
Enquiries sales@genieproducts.co.uk
Website www.genieproducts.co.uk
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>