FEATURES

  • Dual Control Modes: manual or trigger-input
  • High Frequency response
  • Capable of driving variable loads
  • BNC connectors

APPLICATIONS

  • Microscopy
  • Lighting
  • Machine Vision
  • Display
  • Semiconductor equipment
  • Testing instruments
  • Medical instruments

BLS-1000-2/BLS-3000-2 (Front Panel)
Overview

BLS-1000-2/BLS-3000-2 (Rear Panel)
Overview

BLS-13000-1/BLS-18000-1 (Front Panel)
Overview

BLS-13000-1/BLS-18000-1 (Rear Panel)
Overview

PRODUCT DESCRIPTION

Mightex BLS-1000-2, BLS-3000-2, BLS-13000-1, and BLS-18000-1 LED Controllers have two operation modes to control an LED:

Manual Mode: User can control the output current by a turn-counting knob manually.
Trigger Mode: Analog input signal to fully control the output current.

The control mode is selected with a slide switch on the front panel, the factory default is “Manual” mode. BLS-1000-2 and BLS-3000-2 provide Maximum Current Selection DIP switches on rear panel which allow the user to set maximum output current of the channel to 500 / 750 / 1,000mA for BLS-1000-2, and 1,000 / 2,000 / 3,000mA for BLS-3000-2. The factory default is set to 500mA for BLS-1000-2 and 1,000mA for BLS-3000-2. BLS-13000-1 and BLS18000-1 has only one maximum current setting of 13,000mA and 18,000mA, respectively.

When the controller is set to “Trigger” mode, the output current is fully controlled by the input analog signal (0-5V).

ELECTRICAL SPECIFICATIONS

**Parameters** Value Unit
BLS-1000-2 BLS-3000-2 BLS-13000-1
DC Input Voltage 9 ~ 12* 9
DC Input Current > total/combined channel currents** < 2.5
Channel Driving Voltage (Max) Vdc – 4.5 Vdc – 4
Current Accuracy ±3% mA
Channel Driving Current 0 ~ 1,000 0 ~ 3,000
Channel Output Power Limit < 20 < 15
Channel Frequency Response < 100 < 50
External Analog Input 0 ~ 5*** V
  1. When Vforward of LED load is more than 8V, 24V DC input might be used.
  2. The Input current should be more than the sum of output currents of two channels.

FRONT PANEL AND REAR PANEL

(BLS-1000-2/BLS-3000-2)

The Front Panel has power switch and power indicator. For each channel, it has a slide switch (for selecting Manual\ or Trigger mode) and a turn-counting dial (for adjusting output current).
FRONT PANEL

The Rear Panel has a DC input plug (9 ~ 24V DC). For each channel, it has a BNC connector for external trigger/ analog voltage signal (0-5V), a two-pin LED aero connector, and a pair of DIP switches to set the maximum current of the channel
REAR PANEL

(BLS-13000-1/BLS-18000-1):

Front Panel
Front Panel

Front Panel has power switch and power indicator. It also has a slide switch (for selecting Manual or Trigger mode) and a turn-counting dial (for adjusting output current

Rear Panel
Rear Panel

The Rear panel has a DC (12V or 48V) input plug, and it also has a BNC connector for analog input (0-5V), a two pin LED Fan aero connector to drive the fan of the LED light source, and a pair of LED+/LED- to drive the LED light source.

MECHANICAL SPECIFICATION

| BLS-1000-2 / BLS-3000-2| BLS-13000-1 / BLS-18000-1
---|---|---
Dimension| 160mm (L) x 157mm (W) x 68mm (H)| 221mm(L) x 156mm (W) x 96mm ( H )
Weight| 600g| 1300g

INSTALLATION DRAWING

BLS-1000-2 / BLS-3000-2
INSTALLATION DRAWING

BLS-13000-1 / BLS-18000-1
INSTALLATION DRAWING

Singapore Main Office
Telephone: +65 6996 0391
Email: [email protected]

China Main Office
Telephone: +86 15000853620
Email: [email protected]

SIMTRUM logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SIMTRUM User Manuals

Related Manuals