Intense Lighting IS-R1043R10 MX LED Adjustable Remodel Instruction Manual

June 13, 2024
intense LIGHTING

Intense Lighting IS-R1043R10 MX LED Adjustable Remodel

WARNING
Risk of electrical shock. Disconnect power before servicing or installing luminaire.
WARNING
Risk of injury or damage. Luminaire will fail if not installed properly. Follow installation instructions.
WARNING
Risk of injury. Wear safety glasses and gloves during installation and servicing. Allow ample time to cool before handling.

IMPORTANT SAFETY INSTRUCTIONS

  • Read all installation instructions before installing. It is important to save these instructions.
  • Only install and connect LED module with power disconnected at the circuit breaker. Hot plugging, or connecting the module with power on, could damage the LEDs and is not covered by warranty.
  • Connectors on modules and approved housings are keyed for specific voltage combinations; do not force or attempt to bypass connectors.
  • Observe and follow all label information and instructions regarding dry, damp and wet location listings, proper Intense LED module, warnings of installation near combustible materials and/or insulation.
  • Turn off power at circuit breaker before attempting to install or perform maintenance on the fixtures.
  • Be sure to connect ground wire to prevent electric shock or other potential hazards.
  • The product must be installed in a manner consistent with the intended use and in compliance with the national electrical codes and local codes by a person familiar with the construction and operation of the product and the hazards involved.
  • Do not block the trim aperture as this may cause unsafe operating conditions.
  • WARNING: RISK OF FIRE. Non-IC fixture requires that insulation must be kept at least 3” away from all sides of the fixture. Minimum of 90°C supply conductors. Consult a qualified electrician before installation.

WARNING: Use only Intense Lighting trims listed for use with this fixture. Use of trims other than those listed by Intense Lighting is a violation of N.E.C 110-3(B) and voids all warranties.

Installation Instructions

CEILING CUT OUT

  1. Cut out ceiling hole according to size:
    • Round: 4 1/8” (105mm) diameter
    • Square: 4 1/16” x 4 1/16” (103mm x 103mm)
      Note: Oversized holes will not allow fixture and/or trim to fit correctly.

Intense-Lighting-IS-R1043R10-MX-LED-Adjustable-Remodel-
FIG-1

REMOVE COVER PLATE

  1. Remove (2) M3 pan head screws and junction box cover plate.
  2. Remove knockout on cover plate and attach conduit or Romex® cable.

Intense-Lighting-IS-R1043R10-MX-LED-Adjustable-Remodel-
FIG-2

ELECTRICAL CONNECTIONS

  1. Connect ground from fixture to green (GROUND) supply wire, black wire from fixture to black (HOT) supply wire and white wire from fixture to white (NEUTRAL) supply wire. Use UL listed connectors or wire nuts to make the connections (provided by others). Connect dimming wires if applicable, see page 5.
  2. Replace cover plate and (2) M3 pan head screws.

Intense-Lighting-IS-R1043R10-MX-LED-Adjustable-Remodel-
FIG-3

INSTALL HOUSING

  1. Make sure swing out lugs are in a closed position.
  2. Insert driver housing through ceiling opening.
  3. Rest the driver housing in the ceiling plenum.
  4. Push remodel assembly into ceiling opening.

Intense-Lighting-IS-R1043R10-MX-LED-Adjustable-Remodel-
FIG-4

INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883
For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.
© 2022 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

REMODEL ASSEMBLY INSTALLATION
Use a #1 screwdriver to tighten the (3) swing out lugs into open position (Do not overtighten).
Note: Ceiling thickness must be between 5/16” [8mm] and 3/4” [19mm].

Intense-Lighting-IS-R1043R10-MX-LED-Adjustable-Remodel-
FIG-5

SQUARE REMODEL ASSEMBLY INSTALLATION
Adjust fixture to ensure that “TRIM ALIGNMENT” label is facing the wall that needs to be lit.

Intense-Lighting-IS-R1043R10-MX-LED-Adjustable-Remodel-
FIG-6

MODULE INSTALLATION

  1. Check that power is off at breaker, hot plugging may damage LEDs.
  2. Install module at 0º angle.
  3. Connect female quick connect from housing to male quick connect on module.
  4. Snap module into channel and confirm module sits parallel to ceiling line and is securely fastened into housing.

Intense-Lighting-IS-R1043R10-MX-LED-Adjustable-Remodel-
FIG-7

ADJUSTING HORIZONTAL ADJUSTMENT

  1. Loosen fastener with a #1 screwdriver to allow fixture to adjust 359º horizontally.
  2. Place screwdriver in adjustment assist to rotate module to desired horizontal position.
  3. Tighten fastener to lock horizontal adjustment.

ADJUSTING VERTICAL ADJUSTMENT

  1. Loosen knurled head thumb screw to allow fixture to adjust vertically.
  2. Place screwdriver in adjustment assist to rotate module to desired vertical position.
  3. Tighten knurled head thumb screw to lock vertical adjustment.

Intense-Lighting-IS-R1043R10-MX-LED-Adjustable-Remodel-
FIG-9

TRIM INSTALLATION

  1. Position trim alignment label to trim location tab in the fixture.
  2. Snap trim into fixture.
  3. Trim must line up parallel with the module when it is at the 35º position (as shown).

Intense-Lighting-IS-R1043R10-MX-LED-Adjustable-Remodel-
FIG-10

ACCESSORY HOLDER

  1. Rotate release cap by turning counter clockwise.
  2. Install accessories into accessory holder and replace accessory holder’s retaining clip.
  3. Place accessory holder and accessory flush against optic and replace release cap.

Intense-Lighting-IS-R1043R10-MX-LED-Adjustable-Remodel-
FIG-11

OPTIC REPLACEMENT

  1. Remove trim, then remove module from channel and disconnect quick connect.
  2. Rotate release cap by turning counter clockwise.
  3. Set cap and retainer ring aside and change optics.
  4. Align optic pins to slots in module.

Intense-Lighting-IS-R1043R10-MX-LED-Adjustable-Remodel-
FIG-12

DRIVER REPLACEMENT

  1. Adjust vertical angle to 0º and remove module from channel and disconnect quick connect.
  2. Unscrew all three swing out lugs with a #1 screwdriver. Make sure the swing lugs are in the closed position.
  3. Remove the remodel assembly and the driver housing will follow.
  4. Remove cover plate and slide out driver bracket.
  5. Replace new driver on driver bracket and replace module quick connect.

Intense-Lighting-IS-R1043R10-MX-LED-Adjustable-Remodel-
FIG-15

WIRING & DIMMING COMPATIBILITY

  • For use with all Intense Lighting product with supported dimming options.
  • Please check configuration of product for correct dimming protocol.

Phase Dimming or Lutron® LTEA2W Hi-Lume 2-Wire

  • 120V Only
  • Forward 1% / Reverse 5%

COMPATIBLE DIMMERS

  • Product Part Number(s) Type
  • Leviton IPE04 Reverse
  • Leviton IPI06-1LZ Forward
  • Leviton 6633-P Forward
  • Lutron DVELV300P Reverse
  • Lutron DVCL-153P Forward
  • Lutron S600P Forward
  • Cooper DLC03P Forward
  • Cooper DAL06P Forward

Intense-Lighting-IS-R1043R10-MX-LED-Adjustable-Remodel-
FIG-16

0-10V Dimming

  • 120V or 277V
  • Dims down to 1% or 0.1% light output
  • Consult dimming manufacturer for installation instructions and power packs

COMPATIBLE DIMMERS

Manufacturer Part Number(s)

  • HUNT PS-010-IV-120V, PS-010-WH-120V, PS-010-3W-IV-120, PS-010-3W-WH-120V,
  • PS-010-IV-277V, PS-010-WH-277V, PS-010-3W-IV-277V, PS-010-3W-WH-277V,
  • FD-010: PS-IFC-010-IV, PS-IFC-010-WH-120/277V, FD-010: PS-IFC-010-3W-IV,
  • PS-IFC-010-3W-WH-120/277V, FD-010-120V, FD-010-277V
  • Leviton Leviton Centura Fluorescent Control System, IllumaTech™ IP7 Series, DPSPE-212
  • Lightolier ZP600FAM120, MP1500FAM120, V2000FAMU
  • Lithonia LEQ BC, LEQ LVBC, SLD LVBC, SQ1DC
  • Lutron DVTV, NTFTV
  • Synergy ISD BC 120/277

Intense-Lighting-IS-R1043R10-MX-LED-Adjustable-Remodel-
FIG-17

Lutron® LDE1 Hi-Lume EcoSystem

  • 120V or 277V
  • Dims down to 1%
  • Consult dimming manufacturer for installation instructions

COMPATIBLE DIMMERS

  • Product Part Number(s)
  • EcoSystem CS-1L-WM, CS-2L-WM, CS-1L-CM, CS-2L-CM,
  • EcoSystem ESN, Grafik Eye QS with EcoSystem, Quantum

Intense-Lighting-IS-R1043R10-MX-LED-Adjustable-Remodel-
FIG-18

DMX512 RDM (Downlights with RJ45)

  • 120V or 277V
  • Dims Down to 0.1% Light Output
  • RDM Channel Programmable

Intense-Lighting-IS-R1043R10-MX-LED-Adjustable-Remodel-
FIG-19

WIRING & DIMMING COMPATIBILITY

  • For use with all Intense Lighting product with supported dimming options.
  • Please check configuration of product for correct dimming protocol.

DMX512 RDM (Cylinders without RJ45)

  • 120V or 277V
  • Dims Down to 0.1% Light Output
  • RDM Channel Programmable

Intense-Lighting-IS-R1043R10-MX-LED-Adjustable-Remodel-
FIG-20

0-10V With Dynamic Beam

  • 120V or 277V
  • Dims down to 1% or 0.1% light output
  • Consult dimming manufacturer for installation instructions and power packs

COMPATIBLE DIMMERS
Manufacturer Part Number(s)

  • HUNT PS-010-IV-120V, PS-010-WH-120V, PS-010-3W-IV-120, PS-010-3W-WH-120V,
  • PS-010-IV-277V, PS-010-WH-277V, PS-010-3W-IV-277V, PS-010-3W-WH-277V,
  • FD-010: PS-IFC-010-IV, PS-IFC-010-WH-120/277V, FD-010: PS-IFC-010-3W-IV,
  • PS-IFC-010-3W-WH-120/277V, FD-010-120V, FD-010-277V
  • Leviton Leviton Centura Fluorescent Control System, IllumaTech™ IP7 Series, DPSPE-212
  • Lightolier ZP600FAM120, MP1500FAM120, V2000FAMU
  • Lithonia LEQ BC, LEQ LVBC, SLD LVBC, SQ1DC
  • Lutron DVTV, NTFTV
  • Synergy ISD BC 120/277

Intense-Lighting-IS-R1043R10-MX-LED-Adjustable-Remodel-
FIG-21

0-10V With Tunable White

  • 120V or 277V
  • Dims down to 1% or 0.1% light output
  • Consult dimming manufacturer for installation instructions and power packs

COMPATIBLE DIMMERS
Manufacturer Part Number(s)

  • HUNT PS-010-IV-120V, PS-010-WH-120V, PS-010-3W-IV-120, PS-010-3W-WH-120V,
  • PS-010-IV-277V, PS-010-WH-277V, PS-010-3W-IV-277V, PS-010-3W-WH-277V,
  • FD-010: PS-IFC-010-IV, PS-IFC-010-WH-120/277V, FD-010: PS-IFC-010-3W-IV,
  • PS-IFC-010-3W-WH-120/277V, FD-010-120V, FD-010-277V
  • Leviton Leviton Centura Fluorescent Control System, IllumaTech™ IP7 Series, DPSPE-212
  • Lightolier ZP600FAM120, MP1500FAM120, V2000FAMU
  • Lithonia LEQ BC, LEQ LVBC, SLD LVBC, SQ1DC
  • Lutron DVTV, NTFTV
  • Synergy ISD BC 120/277

Intense-Lighting-IS-R1043R10-MX-LED-Adjustable-Remodel-
FIG-22

DALI With Tunable White

  • 120V or 277V
  • Dims down to 0.1%

Intense-Lighting-IS-R1043R10-MX-LED-Adjustable-Remodel-
FIG-23

INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883 For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321. © 2022 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

intense LIGHTING User Manuals

Related Manuals