Hargrove HGESCS-ESATK ANSI Certified Aspen Twig Vent Free Gas Log Set Instruction Manual
- June 13, 2024
- Hargrove
Table of Contents
- Hargrove HGESCS-ESATK ANSI Certified Aspen Twig Vent Free Gas Log Set
- Product Information
- Product Usage Instructions
- IMPORTANT PRE-INSTALLATION AND FIREPLACE SAFETY INFORMATION
- PR EINSTALLATION REUIREMENTS
- PREINSTALLATION SPECIFICATIONS
- FIREPLACE PREPARATION
- GAS CONNECTION
- INSTAL LATION
- OPERATION
- PARTS AND ASSEMBLY IDENTIFICATION – MILLIVOLT VALVE
- TROUBLE-SHOOTING
- LIMITED WARRANTY
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Hargrove HGESCS-ESATK ANSI Certified Aspen Twig Vent Free Gas Log Set
Product Information
The VF Hargrove Vent Free Gas Logs, Element Series, is an unvented gas fired heater designed to operate as a room heater when fitted to a solid fuel burning masonry fireplace or UL 127 approved factory built fireplace with the flue damper closed. It can also be installed in an approved unvented fireplace. This appliance uses air (oxygen) from the room in which it is installed and requires provisions for adequate combustion and ventilation air. It is important to follow the installation and operation instructions provided in this manual for safe and proper usage.
Product Usage Instructions
- Installation and service of the VF Hargrove Vent Free Gas Logs must be performed by a qualified installer, service agency, or the gas supplier.
- Ensure that your fireplace has adequate ventilation for safety.
- Read the instructions fully before installing or operating the gas logs.
- If you smell gas, follow these steps:
- Open a window.
- Do not try to light any appliance.
- Do not touch any electrical switch or use the phone in your building.
- Immediately call your gas supplier from a neighbor’s phone and follow their instructions.
- If you cannot reach your gas supplier, call the fire department.
- The gas logs are designed to supplement a current heating system and should not be used as a primary heat source.
- Do not store or use gasoline or other flammable vapors and liquids near the gas logs or any other appliance.
- Installation and service of the gas logs should only be performed by a qualified professional installer, service agency, or the gas supplier. Improper installation, adjustments, alteration, service, or maintenance can cause personal injury or property damage.
- The gas logs are only suitable for use with the type of gas indicated on the rating plate and cannot be converted for use with other gases.
- Do not burn solid fuels in a fireplace where the gas logs are installed.
- Follow the important pre-installation and fireplace safety information provided in the manual to determine the safest and most efficient location for your Vent Free Fireplace.
- If installing in an approved vent free firebox, refer to their instruction guide for proper installation.
- Ensure that the gas type used is correct. Do not install if the gas type is incorrect. Contact your dealer for immediate assistance.
- Gas log sets must be installed by personnel qualified for installing gas appliances.
- The location of the gas logs must allow for proper clearances for accessibility of servicing and proper operation. Refer to the manual for specific clearance requirements.
IMPORTANT PRE-INSTALLATION AND FIREPLACE SAFETY INFORMATION
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage, personal injury, or loss of life.
WHAT TO DO IF YOU SMELL GAS
- 1.Open a window.
2.Do not try to light any appliance.
3.Do not touch any electrical switch; do not use thephone in your building.
4.Immediately call your gas supplier from aneighbor’s phone. Follow the gas supplier’sinstructions.
5.If you cannot reach your gas supplier, call the firedepartment.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
IMPORTANT: Installation and service must be performed by a qualified
professional installer, service agency, or the gas supplier. Improper
installation, adjustments, alteration, service, or maintenance can cause
personal injury or property damage. Refer to this manual.
This appliance operates as an unvented room heater when fitted to a solid fuel
burning masonry fireplace or UL 127 approved factory built fireplace with the
flue damper closed. It may also be installed in an approved unvented
fireplace.
WARNING: THIS IS AN UNVENTED GAS FIRED HEATER. IT USES AIR (OXYGEN) FROM
THE ROOM IN WHICH IT IS INSTALLED. PROVISIONS FOR ADEQUATE COMBUSTION AND
VENTILATION AIR MUST BE PROVIDED. REFERENCE FUEL GAS CODE NFPA 54, ANSI Z223.1
.
This appliance is designed to supplement a current heating system. It is not
designed to be used as a primary heat source.
NOTE: This appliance is only for use with the type of gas indicated on
the rating plate. This appliance is not convertible for use with other gases.
Solid-fuels shall not be burned in a fireplace where a decorative appliance is
installed.
To determine the safest and most efficient location for your Vent Free Fireplace, you must take into consideration the following guidelines.
- This appliance operates as an unvented room heater certified under ANSI Z21.11.2a when fitted to a masonry or factory built fireplace with the flue damper open or closed. It may also be installed in approved vent free fireplace. If installing in an approved vent free firebox, refer to their instruction guide for proper installation. Solid fuels shall not be burned in a fireplace where an unvented room heater is installed.
- Do not use a natural gas set for propane or a propane set for natural gas. If the gas type is not correct. DO NOT INSTALL. Contact your dealer for immediate assistance. Any change to this heater or its controls can be dangerous.
- Gas log sets must be installed by personnel qualified for installing gas appliances.
- The location must allow for proper clearances for accessibility of servicing and proper operation (see section on Fireplace Clearances .
- Consider a location where heat output would not be affected by drafts, air conditioning ducts, windows or doors. Do not allow fans to blow directly into the fireplace, avoid any drafts that alter burner flame patterns.
- Inspect area surrounding the location chosen for the fireplace for possible air drafts that may affect the flames and possibly cause sooting. Air drafts may be caused by a ceiling fan near the fireplace, a hot furnace or an open door.
- Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies. Young children should be carefully supervised when they are in the same room with the appliance. It is recommended that adults be present when this gas appliance is operating. It is recommended that this unit is not left burning when unattended or while anyone is sleeping.
- Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
- Install in an area providing adequate combustion and ventilation air (see section on adequate combustion and ventilation air requirements.
- Do not install in a building that is of unusually tight construction. Unusually tight construction is defined as construction where:
- Walls and ceiling exposed to the outside atmosphere have a continuous wall vapor retarder with a rating of 1 perm or less with openings gasketed or sealed, and
- Weather stripping has been added on openable windows and doors, and
- Caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetration for plumbing, electrical and gas lines and at other openings.
- Do not install this heater in bedrooms, bathrooms or recreational vehicles.
- This appliance may be installed in an aftermarket manufactured (mobile) home, where not prohibited by state or local codes.
- Maintain adequate clearances around air openings.
- When glass fireplace doors are used, always operate gas log set with the doors fully open to allow for proper combustion air and to keep control valves from overheating.
- Keep appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids. Do not allow clothing or flammable materials on or near the fireplace. The flame in this appliance is not isolated from the air space it heats and it will ignite flammable vapors, dust particles or other combustible materials that come in contact with it which can result in an explosion or fire.
PR EINSTALLATION REUIREMENTS
COMBUSTION AND VENTILATION AIR REQUIREMENT WORKSHEET
WARNING: IF THE AREA IN WHICH THE HEATER MAY BE OPERATED IS SMALLER
THAN THAT DEFINED AS UNCONFINED SPACE OR IF THE BUILDING IS OF UNUSUALLY TIGHT
CONSTRUCTION, PROVIDE ADEQUATE COMBUSTION AND VENTILATION AIR BY ONE OF THE
METHODS DESCRIBED IN THE NATIONAL FUEL GAS CODE, ANSI Z223.1 SECTION 5.3 OR
APPLICABLE LOCAL CODES.
This heater shall not be installed in a confined space or unusually tight
construction unless provisions are provided for adequate combustion and
ventilation air.
The following formula can be used to determine the maximum BTU rating per the
definition of unconfined space:
THE SPACE IN THE ABOVE EXAMPLE IS AN UNCONFINED SPACE BECAUSE THE 61,000 BTU’S
AN HOUR USAGE IS LESS THATN THE 61,440 BTU’S AN HOUR AVAILABLE. IF THE TOTAL
BTU’S AN HOUR USAGE IS GREATER THAN 61,440 BTU’S AN HOUR THEN THE SPACE WOULD
BE A CONFINED SPACE AND ADDITIONAL AIR MUST BE PROVIDED.
The National Fuel Gas Code defines a confined space as a space whose volume is
less than 50 cubic feet per 1,000 BTU per hour (4.8 m3 per kw) of the
aggregate input rating of all appliances installed in that space and
unconfined space as a space whose volume is not less than 50 cubic feet per
1,000 BTU per hour (4.8 m3 per kw) of the aggregate input rating of all
appliances installed in that space. Rooms communicating directly with the
space in which the appliances are installed, through openings not furnished
with doors, are considered a part of the unconfined space.
PREINSTALLATION SPECIFICATIONS
BTU RATINGS AND PRESSURE REQUIREMENTS
LOG SET SIZE
GAS TYPE
MAX. HEAT INPUT (BTU/Hr.)
**GAS INLET PRESSURE MAX.**
MIN. REGULATOR PRESSURE
| 18” SETS
**Natural Propane**
33,000 28,000
10.5” WC 13” WC
5” WC 11” WC
**** 4” WC 10” WC
| 24” SETS
**Natural Propane**
36,000 35,000
10.5”WC 13” WC
5” WC 11” WC
**** 4” WC 10” WC
| 30” SETS
**Natural Propane**
36,000 35,000
10.5” WC 13” WC
5” WC 11” WC
**** 4” WC 10” WC
---|---|---|---
When operating the main burner, use the control knob to raise and lower the
min. and max. heat output. Turn the control knob counterclockwise for max.
heat and clockwise for min heat. Input ratings are shown in BTU per hour and
are for elevations up to 2,000 feet. For elevations above 2,000 feet, input
ratings should be reduced 4% for each 1,000 feet above sea level. Refer to the
National Fuel Gas Code.
WARNING: OPERATION OF THIS APPLIANCE ON GASES FOR WHICH IT IS NOT
EQUIPPED MAY LEAD TO CARBON MONOXIDE POISONING.
FIREPLACE DIMENSIONS AND CLEARANCES
Refer to the following charts to determine the proper size set for your
fireplace.
Minimum Fireplace Dimensions
Log Set| | Front| *Rear|
Size| Height| Width| Width| Depth
18”| 16”| 28”| 22”| 12”
24”| 16”| 34”| 28”| 12”
30”| 16”| 40”| 34”| 12”
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS AND MANTLE CLEARANCES
IMPORTANT: To insure a safe installation into a masonry or factory built
fireplace, the following instructions must be carefully observed. If
installing in a pre-manufactured fireplace follow the clearance requirements
accompanying that fireplace.
Refer to Fig. 1 for the following dimensions:
- A. Minimum left and right clearance to combustible walls = 15”.
- B. Minimum clearance to combustible ceiling = 42”.
- C. Minimum left and right side clearances to mantle = 6”.
Note: Clearances to Combustible Materials and Mantle Clearances are in place to provide adequate spacing to prevent a fireplace mantle or facing from catching fire. In most cases they should also be adequate to prevent any discoloration or warping due to heat. However, each Gas Log installation will present unique circumstances creating many variables beyond the control of the Gas Log Manufacturer, including paint or finish composition, previous heat exposure, quality of construction, air flow patterns etc. Because of these variables we cannot guarantee that heat warping or discoloration will never occur. The possibility of heat damage exists whether burning wood or gas logs.
- IMPORTANT: Woodwork such as mantles and other combustible material must be installed as tested per Fig 2 or Fig 3. Heat resistant material are materials such as gypsum board, sheetrock, slate, tile marble etc. If the mantle and wall are both non-combustible, mantle clearances are not applicable.
- NOTE: A hood (canopy) as shown in Fig 3 is used to deflect heat away from the fireplace face and mantle, reducing the chances of heat damage or discoloration. If using a hood, it must project a minimum of 4” from the face of the firebox. Contact your dealer to purchase a fireplace hood.
PREINSTALLATION CHECKLIST
- INSTALLER: Please leave these instructions with the homeowner.
- HOMEOWNER: Please retain these instructions for future reference.
- State or local codes may only allow operation of this unit in a vented application. Check your state and local codes. All Hargrove vent free room heaters comply with IAS U.S. Requirement 5-95.
- The installation must conform with state and local codes or, in absence of local codes, to the National Fuel Gas Code, ANSI Z223.1
FIREPLACE PREPARATION
IMPORTANT: Before installing in a solid fuel-burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes, and loose paint by a qualified chimney cleaner.
- Turn the gas supply to OFF.
- Turn OFF all electrical power to blower (if applicable) before installing, servicing, or removing.
- Clean the fireplace floor, walls, and chimney (if used) of any ashes, soot creosote, obstruction. This will minimize any smell from the fireplace. We recommend cleaning by a chimney sweep.
- Any outside air ducts and/or ash dumps in the fireplace must be permanently closed at the time of appliance installation.
- A mesh fireplace screen must be in place when the appliance is operating unless other provision for combustion air are provided, the screen shall have an opening(s) for introduction of combustion air.1
This unit complies with 527 CMR 30.00 vent free appliance requirements for Massachusetts.
INSTALLATION
NOTE: Before you proceed, make sure your gas supply is OFF!
-
Check Gas Type: The gas supply must be the same as stated on the heater’s rating plate. If the gas supply is different, DO NOT INSTALL the heater. Contact your dealer for the correct model.
-
IMPORTANT: This appliance cannot be used with or converted to a gas other than the type for which it was equipped at the factory.
-
WARNING: OPERATION OF THIS APPLIANCE ON GASES FOR WHICH IT IS NOT EQUIPPED MAY LEAD TO CARBON MONOXIDE POISONING.
This product must be installed by a licensed plumber or gasfitter when installed within the Commonwealth of Massachusetts. -
WARNING: CONNECTING DIRECTLY TO AN UN-REGULATED L.P. TANK CAN CAUSE AN EXPLOSION.
GAS CONNECTION
WARNING: ANY MODIFICATION TO THIS UNVENTED GAS HEATER OR ITS CONTROLS CAN BE DANGEROUS. IMPROPER INSTALLATION OR USE OF THE HEATER CAN CAUSE SERIOUS INJURY OR DEATH FROM FIRE, BURNS, EXPLOSION OR CARBON MONOXIDE POISONING .
IMPORTANT STEPS TO FOLLOW WHEN MAKING THE GAS LINE CONNECTION
- Consult your gas supplier for proper gas pipe sizing. Normally up to 50’ of ½” inside diameter (ID) gas pipe will supply adequate volume for all vent free units.
- The incoming gas line may be routed into the fireplace either from the left or right side.
- Include a manual shutoff valve in the gas supply line so the appliance may be disconnected for servicing.
- Center the burner system from side to side in the firebox. In a vented firebox, if the damper is used, the burner assembly should be located directly under the damper.
- Use the 3/8” flex connector (provided in the accessory kit) to connect the gas supply line to the regulator on the burner assembly.
- Always use an external regulator for all L.P. appliances to reduce the supply tank pressure to a maximum of 13” W.C. This is in addition to the regulator fitted to the heater.
- Test all connections after turning gas supply on for leaks using a soap and water solution. DO NOT USE AN OPEN FLAME FOR LEAK TESTING.
- It is most convenient to light the pilot and check the operation of the main burner with the logs not in place. After carefully checking the gas supply line for leaks and correcting any found, refer to the “LIGHTING INSTRUCTIONS” section to test the burner assembly.
WARNING: DO NOT USE A BLOWER INSERT, HEAT EXCHANGER INSERT OR OTHER ACCESSORY NOT APPROVED FOR USE WITH THIS HEATER.
GAS PRESSURE CHECK
NOTE: The appliance and the appliance main gas valve must be disconnected
from the gas supply system during any pressure testing of that system at test
pressures in excess of 0.5 psig (3.5 kPa). The appliance must be isolated from
the gas supply piping system by closing its equipment shut-off valve during
any pressure testing of the gas supply piping system at test pressures equal
to or less than 0.5 psig (3.5 kPa).
- The gas valve controls the gas pressure, which can be checked at the pressure test point (1/8” NPT plug) located on the side of the valve (see schematic below).
- The pressure should be checked with the heater burner and the control set to high (HI).
- The pressure is preset and locked to avoid tampering. If the pressure is not as specified in “BTU Rating and Pressure Requirements” (pg. 3), contact your dealer.
- Replace the test plug after measuring gas pressure. Check for gas leaks.
IMPORTANT: Do not use the appliance if any part has been submerged under water. Immediately call a qualified technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
MILLIVOLT WIRING SCHEMATIC
CAUTION: Label all wire prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation. Verify proper
operation after service.
If installing a remote control, thermostat, or timer, attach the leads from
the optional item to the same terminals as the Wall Switch on the Millivolt
Valve.
INSTAL LATION
Element Series 18”/24”/30”
- BURNER MEDIA- refer to Figure 1 to determine the recommended amount of media for your burner. The chart is just a guideline and more or less can be used depending on the desired effect. Refer to FIG 2 & 3 for placement.
- ADDITIONAL KITS- additional logs/twigs, stones, and other decorative pieces may be used with this system. Refer to Fig 2 &3 for placement.
The flame should not come into contact with any media or logs.
Volcanic Cinder Placement
-
Once the burner system is in place, pour the Volcanic Cinder on the floor of the fireplace. DO NOT POUR ANY VOLCANIC CINDER ON THE BURNERS OR AROUND THE PILOT.
-
You may use the Volcanic Cinder to cover up the Lighting Tags that are attached to the set. DO NOT REMOVE THE LIGHTING TAGS FROM THE BURNER SYSTEM. THIS WILL VOID THE MANUFACTURER’S WARRANTY.
The Volcanic Cinder is the large bag of black rock that is included in the log set. The purpose of it is to cover the fireplace floor surrounding the set. The Volcanic Cinder will also cover the metal Lighting Instruction tags and help keep them out of sight. -
You may use the Volcanic Cinder to cover the horizontal portion of the front of the grate. DO NOT POUR VOLCANIC CINDER ON THE BURNER OR AROUND THE PILOT.
OPERATION
FOR YOUR SAFETY READ BEFORE LIGHTING
-
A. This appliance has a pilot which is lighted by a spark igniter system. When lighting the pilot, follow these instructions exactly.
-
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:- Do not try to light any appliance.
- Do not touch any electric switch; do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire department.
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
-
C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Force or attempt repair may result in a fire or explosion and may void your warranty.
-
D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
LIGHTING INSTRUCTIONS
WARNING: At no time should the “LIGHTING INSTRUCTION” tags be detached
from the burner system. Removing the tags will void the manufacturer’s
warranty.
- STOP! Read the safety information above on this label.
- Turn off all electrical power in firebox before installing.
- Depress the control knob and turn clockwise as far as it will go to reach the “OFF” position.
- Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above on this label. If you do not smell gas, go to the next step.
- Depress the Control knob and turn counterclockwise to the “PILOT” position.
- Push in control knob all the way and hold in.
- If the control knob is not held in all the way the pilot will not stay lit when the knob is released. * Do not turn the knob when pushing it in.
7. Light the pilot (mounted in front of the back burner) by pushing the spark igniter button several times. This will cause a spark at the pilot which will ignite the pilot gas. If the spark does not work, light the pilot with a match.
- When lighting the pilot it may take several seconds for gas to reach the pilot.
- Continue to hold the control knob in all the way for about 30 seconds after the pilot is lit.
- Release the knob and it will pop back out. The pilot should remain lit. If it goes out, repeat steps 3 through 9.
- If knob does not pop up when released, stop and immediately call your service technician or gas supplier.
- If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier.
- Depress the control knob and turn counterclockwise to “ON”. Turn flame heightl knob counterclockwise to select desired comfort level.
IMPORTANT: The gas control has an interlock device. After shutting off all gas flow, the pilot burner cannot be relit until the thermocouple has cooled, allowing the electromagnet to be released (approx. 60 sec.). The gas control knob is designed to be operated by hand. DO NOT use any tools during this operation. Damaged knobs may result in serious injury.
NOTE: A periodic visual check of the pilot flames (Figure 11) and main burner flames (Figure 12) should be made. The pilot flame should always be present when the appliance is in operation. See illustrations below.
WARNING: TAMPERING WITH THE ODS PILOT WILL VOID THE MANUFACTURER’S WARRANTY.
TO TURN OFF GAS TO APPLIANCE
- TEMPORARY SHUTDOWN PROCEDURE: To turn off main burner only, depress the knob and turn it clockwise as far as it will go. Do not force.
- COMPLETE SHUT-DOWN PROCEDURE: clockwise as far as it will go. Do not force. Turn off all electrical power in firebox. Turn gas control knob clockwise to the “OFF” position.
Controlling Heat Output
-
The heat output can be controlled by adjusting the vent free burner control knob.
-
Another way to regulate the heat output is to open the fireplace damper.
If you want:- a. more heat radiated into the room – Keep the damper completely closed
- b. less heat radiated into the room – open the fireplace damper to varying degrees.
Important Safeguards
-
To avoid personal injury, do not touch hot surfaces when the appliance is operating. Touch only the piezo ignitor and control knob.
Hot Surfaces- a. Grate
- b. Burner
- c. Logs
- d. Surfaces above the opening of the fireplace
-
Although your gas logs are very realistic in appearance, it is not a real wood-burning fireplace and must not be used for burning any material.
To avoid irreparable damage to the appliance or personal injury, matches, paper, garbage, or any other material must not be placed or thrown on top of the logs or into the flames. Close supervision is necessary when the appliance is being operated near children. Avoid any drafts that alter burner patterns. Do not allow fans to blow directly into the fireplace. Ceiling fans may create drafts that alter burner flame patterns. Sooting and improper burning will occur.
Cleaning And Servicing
Installation and repair should be done by a qualified service person. The
appliance should be inspected before use and at least annually by a
professional service person. More frequent cleaning may be required due to
excessive lint from carpeting, bedding, and material, etc. It is imperative
that control components, burners and circulating air passageways of the
appliance be kept clean.
- If the flames show any unusual shapes or behavior, or the burners fail to ignite properly, then the burner holes may require cleaning.
WARNING: TURN OFF VENT FREE BURNER SYSTEM AND ALLOW TO COOL BEFORE CLEANING OR SERVICING.
MONTHLY CLEANING
- If removing logs, when reinstalling, refer to “Log Assembly Diagram” for correct log placement.
- Do not use cleaning fluids to clean logs or any part of the heater.
- Brush logs with a soft bristle brush or vacuum with brush attachment.
- Vacuum loose particles and dust from the front and rear burner ports, gas control, piezo cover, and grate.
- Inspect and clean ODS pilot for operation and accumulation of lint at air intake holes.
- Verify flame pattern and log placement for proper operation.
- Verify smooth and responsive ignition of main burner and rear burner. Refer to page for proper pictorial sketch of proper operation.
ANNUAL CLEANING AND INSPECTION
- Dealer or qualified inspector – follow the above steps for proper servicing and inspection.
PARTS AND ASSEMBLY IDENTIFICATION – MILLIVOLT VALVE
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.
Millivolt Vent Free Burner Assembly
ITEM| DESCRIPTION| QTY| ESCS18(N,P)2C| ESCS24(N,P)2C|
ESCS30(N,P)2C
---|---|---|---|---|---
A.| BURNER SUB-ASSEMBLY| 1| SFES-18| SFES-24| SFES-30
B.| MILLIVOLT VALVE (2C)| 1| DEX-MIL-VF-V| DEX-MIL-VF-V| DEX-MIL-VF-V
C.| OXYGEN DEPLETION SYSTEM (2C) (NG)| 1| OP-8205-MODS-NG| OP-8205-MODS-NG|
OP-8205-MODS-NG
| OXYGEN DEPLETION SYSTEM (2C) (LP)| 1| OP-8405-MODS-LP| OP-8405-MODS-LP|
OP-8405-MODS-LP
D.| SPARK IGNITOR| 1| PIEZO| PIEZO| PIEZO
E.| SPARK IGNITOR CABLE| 1| SIT-16 CABLE| SIT-24 CABLE| SIT- 24CABLE
F.| ON/OFF SWITCH| 1| RS| RS| RS
G.| 3/8” FL X 3/8” MIP BRASS 45| 1| 409-6-6-45| 409-6-6-45| 409-6-6-45
H.| 3/8”FL X 3/8” MIP BRASS| 1| 48-6| 48-6| 48-6
I.| BRASS ELBOW FOR ORIFICE| 1| 49-6-6Z2| 49-6-6Z2| 49-6-6Z2
| ORIFICE SPUD| 1| PPH-2| PPH-2| PPH-2
J.| FLEX CONNECTOR| 1| FC-16| FC-24| FC-24
K.| FEET FOR REFLECTIVE PANEL| 2| CNT-FT| CNT-FT| CNT-FT
L.| REFLECTIVE BACK PANEL| 1| CNT-SSBACK18| CNT-SSBACK24| CNT-SSBACK30
TROUBLE-SHOOTING
Hargrove Manufacturing test fires all Vent Free burner systems before shipment. Each test consists of lighting the pilot, checking for proper ignition, and leak testing at each connection. Even though all of these precautions are taken sometimes problems do arise. The following Trouble- Shooting chart lists several problems with their probable cause and remedy.
WARNING: TURN OFF AND LET COOL BEFORE SERVICING. ONLY A QUALIFIED SERVICE PERSON SHOULD SERVICE AND REPAIR.
LIMITED WARRANTY
-
Logs
Hargrove gas logs carry a limited lifetime warranty against any manufactured defect or breakage. A replacement will be available from the dealer at which the appliance was purchased. This warranty does not cover breakage caused by excessive handling once installed and fired. -
Burner & Grate
If the burner or grate fails due to deterioration within five (5) years of the verified purchase date, a free replacement will be made available from the dealer at which the appliance was purchased. -
Valves, Remote Controls, & Switching Devices
Hargrove warrants all valves, remote controls and switching devices against manufacturing defects which appear within two (2) years of the verified purchase date. Warranty does not cover products that have been damaged by misuse from overheating. Before any product is returned a Return Goods Authorization number (RGA) must be issued by Hargrove’s Customer Service Department. All returns must be accompanied by an explanation of the problem and all necessary parts. -
All Other Parts
If any assembled part should fail to operate or be found defective which appear within two years of the verified purchase date, a replacement will be available from the dealer at which the appliance was purchased. Buyer shall notify Hargrove Mfg Corp. of any defect covered by this warranty no later than thirty (30) days after defect is discovered. Failure to provide notice within thirty (30) days shall void the limited warranty.
WHAT IS NOT COVERED
- Removal and reinstallation costs.
- Labor costs for replacement or repairs.
- Transportation or shipping cost.
- The cost of a service call to diagnose trouble.
- Painted Surfaces.
- Damage or defect caused by improper installation, accident, misuse, abuse, alteration, or authorized service technician.
- Replacement of burner or combustion chamber resulting from improper storage of the appliance.
LIMITATIONS AND EXCLUSIONS
- No one has authority to add to or vary this limited warranty, or to create for Hargrove Manufacturing Corporation any other obligation or liability in connection with this appliance.
- Any implied warranty applicable to this appliance is limited in duration to the same period of time as this written Warranty. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.
- HARGROVE MANUFACTURING CORPORATION WILL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL, SPECIAL OR CONTINGENT DAMAGES YOU MIGHT SUFFER AS A RESULT OF A CLAIM UNDER THIS WRITTEN WARRANTY OR ANY IMPLIED WARRANTY. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusion may not apply to you.
- This warranty applies only to the original purchaser and may not be transferred or assigned.
- If you cannot verity the purchase date of the appliance, the warranty period will begin on the date of which the appliance was manufactured.
- Replacement or repair parts are warranted for the remaining period of the original part warranty. Warranty parts must be obtained through authorized dealers of this product who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty.
- The maximum liability of Hargrove Mfg Corp. in connection with this limited warranty shall not in any case exceed the contract price paid for the product claimed to be defective or unsuitable.
- Purchaser or user agrees to hold Hargrove Mfg Corp. harmless from any and all claims by the buyer as a result of injury or damage to an ultimate user or other person caused by the product sold herein by the seller to the buyer, whether the injury or damage results from the assembly, installation, operation, shipment, storage, or manufacture of this product. Hargrove Mfg Corp. makes no warranties, expressed or implied, other than those expressly stated herein.
YOUR DUTIES
This appliance must be installed by a qualified installer, operated and
maintained in accordance with all applicable codes and the instructions
furnished with the appliance. You must provide a receipt verifying the
purchase date of the appliance when making a warranty claim with the dealer
from which the appliance was purchased. This warranty gives you specific legal
rights, and you may also have other rights, which vary from state to state.
CONTACT INFO: Hargrove Manufacturing Corp.
Tele: 800-725-4166