SignalShark 3320 Remote Unit
Quick start guide
SignalShark 3320 Remote Unit
Narda Safety Test Solutions GmbH
Sandwiesenstraße 7
72793 Pfullingen, Germany
® Names and Logo are registered trademarks of Narda Safety Test Solutions GmbH
– Trade names are trademarks of the owners.
© 2022
Order no.: 3320/98.12
Issue: 02/01.2022
Previous issues: 01/01/2019
Subject to change.
Our normal terms of warranty and delivery apply.
Printed in Germany
About this guide
Following instructions are supplied with the device:
- This Quick Start Guide: These instructions offer a quick introduction on how to use the product. The Quick Start Guide does not replace the detailed operation manual.
- Online help: The complete operation manual can be found on the device (see Operating the SignalShark 3320 on page 34) and on the enclosed USB device.
- General safety instructions: The enclosed document Narda General Safety Instructions (3300/98.10) contains important information on how to avoid injury from incorrect use and on the correct handling of the product.
⇒ Be sure to read the Quick Start Guide and the General safety instructions before operating the device and follow all instructions provided there.
⇒ Store both documents with the device and make them available to all users.
⇒ When transferring the device to third parties, also forward these instructions to them.
About this product
The SignalShark 3320 Remote Unit exists in different module versions which are
adapted for remote control applications. It can be used as a stand-alone unit
for desktop (optionally with equipment feet) and system operation. Narda also
offers the SignalShark 3320 as modular units for installation in a 19” rack.
All SignalShark types support the same GUI. The SignalShark 3320 can be
operated via a remote desktop connection or by using an external monitor, a
keyboard and a mouse. The SCPI command reference and VITA 49 compliant I/Q
streaming allow easy integration into any software environment.
The SignalShark 3320 features a highly sensitive and dynamic RF front-end with
four switchable RF inputs. The spectrum analyzer works ultrafast in scan mode
(40 MHz real-time bandwidth). It calculates FFTs of up to 16,384 points with
at least 75% overlap.
There is also an independent receiver path (40 MHz real-time bandwidth). The
center frequency and the channel bandwidth are freely selectable. The path
allows you to perform channel level measurements, modulation analysis, audio
demodulation, and I/Q streaming.
The SignalShark 3320 supports the automatic direction finding antennas from
Narda. Bearing cycles down to 1.2 ms are possible. The integrated map and
localization software allow reliable localization, even in urban environments.
Due to its precise time stamp synchronization and Vita 49 I/Q streaming, the
SignalShark 3320 offers an excellent TDOA-based localization system. As
reference clock, you can select the PPS signal of the internal GNSS receiver,
or that of the ADFA’s GNSS receiver, or from a dedicated PPS input.
The CPU of the SignalShark 3320 is designed to run third-party software and
scripts. This allows you to easily extend its capabilities or build your
customized stand-alone system.
Unpacking
3.1 Packaging
The packaging is designed to be re-used if it has not been damaged during
previous shipping. Please keep the original packaging and use it again
whenever the device is shipped.
3.2 Package contents
The package contents are listed on the delivery note. Please check that you
have received all the items listed. Contact your supplier if anything is
missing.
3.3 Checking the device for shipping damage
After unpacking, check the device and all accessories for any damage that may
have occurred during shipping. Damage may have occurred if the packaging
itself has been clearly damaged. Do not attempt to use a device that has been
damaged.
3.4 Recovery after shipping and storage
Condensation can form on a device that has been stored or shipped at a low
temperature when it is brought into a warmer environment. To prevent damage,
wait until all condensation on the surface of the device has evaporated. The
device is not ready for use until it has reached a temperature that is within
the guaranteed operating range. For temperature ranges see the corresponding
datasheet (https://www.narda-sts.com).
Device overview
The technical specifications may change due to product developments. The
latest technical specifications can be found in the datasheet of the product.
The datasheet can be downloaded from the Narda website www.narda-
sts.com under the corresponding product
page. Front
panel
1| ON/OFF button
The device starts automatically when connected to the power supply
---|---
2| LED to indicate the operating status of the device
For more information, refer to Displaying the operating status on page 32
3| stereo jack, 3.5 mm headphone jack
4| LEDs indicating the status for remote control and I/Q streaming
For more information, refer to Display the LAN interface status: on page 33
5| Product description on the top of the device
QR codes including P/N, S/N, Mac address, etc.
6| Display port
7| USB 2.0 connection
Back panel
1 | 3 x RF SMA(f) input |
---|---|
2 | RF N(f) input |
3 | 12-pin jack for connecting the antenna control cable |
4 | 10 MHz Ref SMA(f) input, 600 Ω |
5 | USB 3.0 connection |
6 | External GNSS SMA(f) input, 50 Ω |
DC voltage for active antenna is supplied
7| Product description including P/N, S/N, Mac address
8| Micro SD card slot (microSDXC)
9| PPS/trigger SMA(f) input, 100 kΩ
10| 1 GigE connector
For remote control, I/Q streaming, and network connection, e.g. the Internet
access for Win10
11| DC input
Assembling the SignalShark 3320
NOTICE
Overheating
Overheating of the device due to poor air circulation (i.e., as a result when
the ventilation slots of the device are covered) can lead to malfunctions and
damage.
⇒ Make sure that the device is operated within the ambient temperature range
stated in the specifications of the datasheet.
⇒ Make sure that there is adequate space around the device and that there is
sufficient ventilation.
⇒ Do not cover the ventilation slots on the front and back (and, if possible,
also not on the top and bottom).
5.1 Stand-alone operation
The SignalShark 3320 can be used as a stand-alone unit. For desktop use, the
device can be mounted with equipment feet to ensure surface protection.
⇒ Mount the enclosed equipment feet to the intended mounting positions on the
bottom of the SignalShark 3320. 5.2 Modular operation
The SignalShark 3320 can be used as modular units in a 19“ rack. The modular
system is available in both single (Figure 3) and dual (Figure 4) versions and
are supplied with mounted front panel. Mounting the SignalShark 3320 in the rack:
- Place the SignalShark 3320 in the intended compartment.
- Screw the SignalShark 3320 to the rack using the holes in the front panel (see arrows in Figure 3 and Figure 4).
Installing connections
6.1 Power supply
The SignalShark 3320 is operated via an AC/DC adapter.
⇒ Connect the AC/DC adapter to the DC power input of the SignalShark 3320. If
you use a screw connection, you must screw the cable connector to the power
input to ensure a reliable power supply.
The device starts automatically when connected to the power supply.
6.2 Connecting RF connectors
Use the RF inputs (three RF SMA inputs + one RF N input) located on the back
of the SignalShark 3320 to connect RF connectors.
When using an RF SMA input:
⇒ Connect the SMA plug to the SMA socket (see Figure 2: caption 1) and
carefully tighten the SMA connection with a torque wrench.
NOTICE
Exceeding the maximum torque
The SMA connection may be damaged, when exceeding the maximum torque.
⇒ Do not exceed the maximum torque of 0.6 Nm.
⇒ Do not tilt and turn the cable while screwing.
6.3 Installing the Narda automatic DF antennas
The SignalShark 3320 is intended for use with the automatic DF antennas. For
the use of other Narda antennas as well as cables and antennas from other
manufacturers, refer to the operation manual. The operation manual can be
found on the USB device or in the SignalShark online help (for details on how
to access the online help, refer to Operating via the graphical user interface
(GUI) on page 34).
A detailed procedure on how to replace the RF cable on the Automatic DF
Antenna can be found in the Narda Automatic DF Antenna Handling and Safety
Instructions (3360/98.12).
Connecting the RF cable to the SignalShark 3320
The RF cable has two connections:
- Control connection (1): for power supply as well as for the transmission of compass data and control signals
- N connection (2): for transmitting the RF signal
Connecting the RF cable:
- Place the control cable plug of the RF cable on the control connector of the basic unit (1), so that the red marking on the plug points downwards and forms a line with the slot in the control connector.
- Press the plug with the locking bush into the connection until the plug lock is engaged.
- Place the N connector plug of the RF cable on the N connector of the basic unit (2) and screw down carefully the union nut and without tilting.
NOTE: Make sure that the cable does not turn while screwing. Otherwise,
the electrical properties of the high-quality coaxial cable could be impaired
by tor- sional forces. If you notice any resistance when tightening, the union
nut must be loosened, cleaned and
tightened again. Approx. 4 rotations are necessary to create a tight
connection.
Unscrewing the plug:
- Unscrew the union nut (2) at the N connection.
- Pull the control cable connector (1) on the ribbed plug head backwards until the lock disengages.
6.4 Setting up the device control
The SignalShark 3320 can be connected in the following ways:
Connecting the SignalShark 3320 to a network
This is the standard connection type. The default setting of the SignalShark
3320 is DHCP = On. The SignalShark 3320 can then be operated via remote
commands or remote desktop.
- Connect the SignalShark 3320 to a network using a standard Ethernet cable (patch cable).
- Configure your network. For more information, refer to Setting up the network configuration on page 32.
Connecting a monitor and accessories to the
SignalShark 3320
This type of connection allows you to operate the SignalShark 3320 without a
network. In this way you can, for example, assign an IP address manually if no
DHCP server is available.
- Connect a monitor to the display port (see Figure 1, caption 6).
- Connect a keyboard and a mouse to the USB ports (see Figure 1: caption 7, and Figure 2: caption 5 ).
Starting up the SignalShark 3320
7.1 Switching the device on and off
Make sure that all the connections have been made properly (see Installing
connections on page 29).
⇒ Connect the AC/DC adapter to the DC power input of the device.
⇒ The device turns on automatically.
⇒ To switch the unit off, press the key for at least 0.5 second. For a hard
shutdown, press the key for several seconds (5–10 seconds).
⇒ To restart the device, press the key again.
Displaying the operating status
The LED light (see Figure 1: caption 2) indicates the operating status:
- LED lights up green: Device is operational
- LED lights up red: Device is in initialization phase or an error occurred
7.2 Setting up the network configuration
For details on the possible connection types, refer to Setting up the device
control on page 31.
Automatic configuration
The SignalShark 3320 is connected to a network using a DHCP server.
The configuration parameter DHCP is set to ON by default.
The IP address is automatically assigned to the SignalShark 3320 by the DHCP
server.
Manual configuration
NOTE: Changing the network settings requires admin privileges.
The SignalShark 3320 is connected to a network.
The SignalShark 3320 is running on the same subnetwork and there are no
firewalls or network gateways, etc., that prevent data communication.
A monitor, keyboard and mouse are connected to the SignalShark 3320 (for more
information, refer to Connecting a monitor and accessories to the SignalShark
3320 on page 31).
Set the network parameters on the SignalShark 3320:
- Tap > Network.
- Set DHCP to OFF.
- Enter the IPv4 address and Subnet mask (if already defined for the SignalShark 3320 in the network server).
- Tap Accept Settings.
- In the confirmation dialog, enter your password and confirm.
Set the network parameters on the network server:
- Enter the IPv4 Address assigned to the SignalShark 3320 (if not already assigned).
- Enter the Mac address of the SignalShark 3320 if required. You can find the Mac address on the label on the back (see Figure 2: caption 7) of your SignalShark 3320 or in the network settings menu.
7.3 Checking the remote interface ready status
The Status LED glows green as soon as the boot process is completed, and the
communication function is working for the remote interface. This process takes
at least 20 seconds.
Display the LAN interface status:
The LED light (see Figure 1: caption 4) indicates the LAN interface status:
- LED LINK lights up orange: 100 Mbit
- LED LINK lights up green: 1 Gbit
- LED ACT lights up green: Traffic
To test the device connection:
The LED LINK lights up green or orange.
- Open a command-line program (cmd.exe) to execute commands in Windows.
- Send a PING command to test the Ethernet link.
7.4 Operating the SignalShark 3320
The SignalShark 3320 can be operated in the following ways:
Operating via the graphical user interface (GUI)
⇒ To operate the SignalShark 3320 via the GUI, establish a remote desktop
connection or connect a monitor, keyboard and mouse (for a detailed procedure,
refer to chapter Setting up the device control on page 31).
For detailed information about how to operate the SignalShark 3320, refer to
the SignalShark online help.
⇒ To access the online help, press the F1 key.
NOTE: The keys described in the online help are not available for the
SignalShark 3320. In this case, you need to apply the appropriate keyboard
shortcut. A list of all shortcuts can be found in the online help under Basic
Operation > Keypad and Keyboard.
Operating via remote control commands
⇒ To operate the SignalShark 3320 via remote control commands, connect it to a
network.
For a detailed list of commands for remote control of the SignalShark 3320,
refer to the Command Reference Guide. You can access the Command Reference
Guide via the online help or by downloading the PDF from the Narda website
(customer login required) at www.narda-sts.com.
Cleaning
⇒ Please observe the information for cleaning in the Narda General Safety Instructions.
Calibration, repair, and modification
⇒ Please observe the information for calibration, repair, and modification in the Narda General Safety Instructions.
Declaration of conformity
Hereby, Narda STS declares that this equipment is in compliance with the
directives 2014/30/EU, EN 61326-1:2013, 2014/35/EU, EN 61010-1:2010, and
2011/65/EU.
The full text of the EU declaration of conformity is available at www.narda-
sts.com.
Proper disposal (EU only)
11.1 Disposal of used equipment
The crossed-out wheeled garbage can symbol indicates that this product is
subject to the European WEEE Directive 2012/19/EU on the disposal of waste
electrical and electronic equipment and must be disposed of separately from
household waste in accordance with your national regulations.
In the European Union, all electronic measuring systems purchased from Narda
after August 13, 2005 can be returned at the end of their useful life.
⇒ For more information, please contact your Narda distributor.
11.2 Disposal of removable batteries
Batteries must not be disposed of in household waste, but must be disposed of
separately from the product in accordance with the applicable regulations.
They can be returned free of charge to the appropriate collection points, your
dealer or directly via Narda.
⇒ Please discharge the batteries before disposal.
11.3 Disposal of permanently installed batteries
Your instrument has permanently installed LiCF batteries, which cannot be
removed non-destructively by the user.
Non-destructive removal is only possible by Narda itself or by qualified
personnel.
⇒ Instructions for non-destructive removal of the batteries can be found on
the Narda website www.narda-sts.com under the
corresponding product page.
11.4 Deleting private data
⇒ Make sure that you delete any stored private data before passing on or
disposing of the device.
SignalShark 3320 Remote Unit
Narda Safety Test Solutions GmbH
Sandwiesenstrasse 7
72793 Pfullingen, Germany
Phone +49 7121 97 32 0
info@narda-sts.com
Narda Safety Test Solutions
North America Representative Office
435 Moreland Road
Hauppauge, NY11788, USA
Phone +1 631 231 1700
info@narda-sts.com
Narda Safety Test Solutions GmbH
Beijing Representative Office
Xiyuan Hotel, No. 1 Sanlihe Road, Haidian
100044 Beijing, China
Phone +86 10 6830 5870
support@narda-sts.cn
www.narda-sts.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>