Schneider Electric Harmony GTU Backup Recovery User Manual
- June 13, 2024
- Schneider Electric
Table of Contents
- Schneider Electric Harmony GTU Backup Recovery
- Product Information
- Legal Information
- Information
- Presentation of the Backup Recovery Tool
- Backing up the System with a PC Requirements
- Restoring the system with a PC
- Backing up the System from HMIG5U
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Schneider Electric Harmony GTU Backup Recovery
Product Information
- Product Name: Harmony GTU Backup Recovery User Manual
- Model Number: NVE9304402_04
- Brand: Schneider Electric
- Website: www.se.com
Legal Information
The Schneider Electric brand and any trademarks of Schneider Electric SE and its subsidiaries referred to in this guide are the property of Schneider Electric SE or its subsidiaries. All other brands may be trademarks of their respective owners.
This guide and its content are protected under applicable copyright laws and furnished for informational use only. No part of this guide may be reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise), for any purpose, without the prior written permission of Schneider Electric.
Schneider Electric does not grant any right or license for commercial use of the guide or its content, except for a non-exclusive and personal license to consult it on an “as is” basis. Schneider Electric products and equipment should be installed, operated, serviced, and maintained only by qualified personnel.
As standards, specifications, and designs change from time to time,
information contained in this guide may be subject to change without notice.
To the extent permitted by applicable law, no responsibility or liability is
assumed by Schneider Electric and its subsidiaries for any errors or omissions
in the informational content of this material or consequences arising out of
or resulting from the use of the information contained herein.
Information
NOTICE
Read these instructions carefully, and look at the equipment to become
familiar with the device before trying to install, operate, service, or
maintain it. The following special messages may appear throughout this
documentation or on the equipment to warn of potential hazards or to call
attention to information that clarifies or simplifies a procedure.
The addition of this symbol to a “Danger” or “Warning” safety label indicates
that an electrical hazard exists which will result in personal injury if the
instructions are not followed.
This is the safety alert symbol. It is used to alert you to potential personal
injury hazards. Obey all safety messages that follow this symbol to avoid
possible injury or death.
DANGER
DANGER indicates a hazardous situation which, if not avoided, will
result in death or serious injury.
WARNING
WARNING indicates a hazardous situation which, if not avoided, could result
in death or serious injury.
CAUTION
CAUTION indicates a hazardous situation which, if not avoided, could result
in minor or moderate injury.
NOTICE
NOTICE is used to address practices not related to physical injury.
PLEASE NOTE
Electrical equipment should be installed, operated, serviced, and
maintained only by qualified personnel. No responsibility is assumed by
Schneider Electric for any consequences arising out of the use of this
material.
A qualified person is one who has skills and knowledge related to the
construction and operation of electrical equipment and its installation, and
has received safety training to recognize and avoid the hazards involved.
About the Book
- Backup and recover the system of Harmony GTU boxes.
- Read and write complete CFast or SD card from/to an image file.
Validity Note
This documentation is valid for Harmony GTU boxes. the original system is
included in the backup and recovery DVD1, delivered with this product.
1 The recover DVD is not included in some Open Box models. In this case, back up the data with the factory settings or after installing the required application programs.
Registered Trademarks
Microsoft® and Windows® are registered trademarks of Microsoft Corporation in
the United States and/or other countries.
Product names used in this manual may be the registered trademarks owned by
the respective proprietors.
Related Documents
NOTICE
RISK OF MALFUNCTION
Start the software only once.
Failure to follow these instructions can result in equipment damage.
Presentation of the Backup Recovery Tool
- Backup and recover the system of Harmony GTU boxes.
- Read and write complete CFast or SD card from/to an image file. The card will be completely saved in one file.
You can compress and verify system image file during the backup operation. For
HMIG5U, the original system is included in the backup and recovery DVD1,
delivered with Harmony product.
1 The recover DVD is not included in some Open Box models. In this case, back up the data with the factory settings or after installing the rquired application programs.
Backing up the System with a PC Requirements
CFast/SD card memory card reader/writer depending of the box model. Computer running Windows®:
- Windows® 7 (32/64bit)
- Windows® 8 (32/64bit)
- Windows® Embedded Standard 7 (32/64bit)
- Windows® 10 (32/64bit)
Procedure
To back up the system with a PC, please follow the steps given below:
Note: Do not back up the CFast card with either hibernation or HORM enabled.
Step | Action |
---|---|
1 | Insert the CFast/SD card (from Harmony GTU boxes) in the card reader of |
PC.
2| Launch Backup Recovery available on Backup and Recovery DVD or
Start Menu.
3| Select type of media: CFast/SD card.
Step | Action |
---|---|
4 | In the Backup & Recovery window: |
- Select the file name and location where to create the Image file.
- **** Refresh the drive letter by clicking the corresponding button.
- **** Select the card to be backed up in the dropdown list.
- ** Select the Compress and/or Verify** check boxes.
- Click the Backup button.
- A bar graph displays the progress. At 100% the backup time is displayed, exit using the Exit button.
Restoring the system with a PC
CFast /SD card memory card reader/writer depending of the box model. Computer running Windows®:
- Windows® 7 (32/64bit)
- Windows® 8 (32/64bit)
- Windows® Embedded Standard 7 (32/64bit)
- Windows® 10 (32/64bit)
To restore the system with a PC, please follow the steps given below:
Step | Action |
---|---|
1 | Insert the target CFast/SD card in the card reader of PC. |
2 | Launch BackupRecovery available on Backup and Recovery DVD or Start |
Menu.
3| Select type of media: CFast/SD card.
Step | Action |
---|---|
4 | In the Backup & Recovery window: |
- **** Select the file name and location where the source system to recover is located.
- Refresh the drive letter clicking the corresponding button.
- **** Select the CFast /SD card to be recovered.
- ** Click the Recovery** button.
- A bar graph displays the progress. At 100% the backup time is displayed, exit using the Exit button.
Backing up the System from HMIG5U
Requirements
- A CFast with boot system.
- A second CFast with the system to backup.
- An external archive media (hard disk drive or USB key) connected to the USB port.
- Note : You can use either a system CFast from another HMIG5U or create a new system CFast by following the procedure to recover the system from the HMIG5See page 11).
- Note: A second CFast for system backup is not included with HMIG5. Schneider Electric reference (32 GB) CFast: HMIZCFA32S.
Preconditions
NOTICE
RISK OF MALFUNCTION
Make sure the space on the external archive media connected on the USB port
is sufficient.
Failure to follow these instructions can result in equipment damage.
Procedure
To backup the system from the HMIG5 please follow the steps given below:
Note: Do not back up the CFast card with either hibernation or HORM enabled.
Step | Action |
---|---|
1 | Insert the boot system Cast in the slot 1 (system card). |
2 | Insert the system Cast to be backed up in the slot 2. |
3 | Start the HMIG5Ulll system. |
4 | Launch Backup Recovery available on Backup and Recovery DVD or Start |
Menu.
5| For backup procedures, refer to Backing Up the System with a PC.
Restoring the System from HMIG
- A CFast with boot system.
- A second CFast (blank).
- An image file to recover
- From the backup and recovery DVD.
- From an external archive media (hard disk drive or USB key).
- Note: A second CFast for system backup is not included with HMIG5 Schneider Electric reference (32 GB) CFast: HMIZCFA32S.
- Note : Data will be overwritten if second CFast is not blank.
Procedure
To restore the system from the HMIG, please follow the steps given below.
Step | Action |
---|---|
1 | Insert the boot system CFast in the slot 1 (system card). |
2 | Insert destination CFast in the slot 2. |
3 | Start the HMIG5Ulll system. |
4 | Launch BackupRecovery available on Backup and Recovery DVD or Start |
Menu.
5| For recovery procedures, refer to Restoring the System with a PC.