Emaux HE40 Heat Exchanger User Manual

June 13, 2024
Emaux

Emaux HE40 Heat Exchanger

Emaux-HE40-Heat-Exchanger-PRO

Product Information

Heat Exchanger

  • Model: HE40 / HE60 / HE75 / HE120
  • Chlorine content: maximum 3 mg/lppm
  • Chloride content: maximum 250 mg/lppm
  • pH value: 7.2 – 7.8
  • Alkalinity: 60 – 120 mg/lppm
  • Calcium hardness: 200 – 1000 mg/lppm
  • Max. pressure: primary 10 bar, secondary 5 bar

Product Usage Instruction

Installation Steps:

  1. Connect the heat exchanger to the main drain pump.
  2. Connect the heat exchanger to the temperature controller.
  3. Connect the heat exchanger to the filter using an electromagnetic valve.
  4. Connect the heat exchanger to the circulation system, such as a boiler, solar panels, or heat pump.
  5. Connect the waste outlet to the circulation system, such as a boiler, solar panels, or heat pump.

Note: Ensure that the heat exchanger is installed according to the provided installation diagram for optimal performance and safety.

Additional Information:
If you have any further questions or need assistance with the product, please refer to the EM HE15031278 code and contact our customer support.

INSTALLATION

  • Install the heat exchanger according to the illustration.
  • If the heat exchanger is installed above the pool water surface, the tubes shall be placed in a loop to avoid self-drainage of the heat exchanger.
  • The heat exchanger must not be covered or installed against inflammable material.
  • Dosage of chlorine, acid or similar, must be done after the heat exchanger to avoid corrosion.
  • If the pool circulation ceases or is shut off, the circulation pump on the primary side shall be shut off too.
  • In case of climate with sub-zero temperatures, or if the pool is closed for the winter or for more than 1 month, the heat exchanger must be completely emptied.
  • The heat exchanger must not be used in salt water or in pools where a chlorinator is used.
  • Follow the instructions stated below:
    • Chlorine content: max 3 mg/l (ppm)
    • Chloride content: max 250 mg/l(ppm)
    • pH-value: 7.2-7.8
    • Alkalinity: 60-120 mg/l (ppm)
    • Calcium hardness: 200-1000 mg/l (ppm)
    • Max. temperature: 130°C
    • Max. pressure: primary 10 bar, secondary 5 bar

INSTALLATION DIAGRAM

HE SERIES HEAT EXCHANGER INSTALLATION DIAGRAM

Emaux-HE40-Heat-Exchanger-1

Documents / Resources

| Emaux HE40 Heat Exchanger [pdf] User Manual
HE40 Heat Exchanger, HE40, Heat Exchanger
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Emaux User Manuals

Related Manuals