Emaux HE40 Heat Exchanger User Manual
- June 13, 2024
- Emaux
Table of Contents
Emaux HE40 Heat Exchanger
Product Information
Heat Exchanger
- Model: HE40 / HE60 / HE75 / HE120
- Chlorine content: maximum 3 mg/lppm
- Chloride content: maximum 250 mg/lppm
- pH value: 7.2 – 7.8
- Alkalinity: 60 – 120 mg/lppm
- Calcium hardness: 200 – 1000 mg/lppm
- Max. pressure: primary 10 bar, secondary 5 bar
Product Usage Instruction
Installation Steps:
- Connect the heat exchanger to the main drain pump.
- Connect the heat exchanger to the temperature controller.
- Connect the heat exchanger to the filter using an electromagnetic valve.
- Connect the heat exchanger to the circulation system, such as a boiler, solar panels, or heat pump.
- Connect the waste outlet to the circulation system, such as a boiler, solar panels, or heat pump.
Note: Ensure that the heat exchanger is installed according to the provided installation diagram for optimal performance and safety.
Additional Information:
If you have any further questions or need assistance with the product,
please refer to the EM HE15031278 code and contact our customer support.
INSTALLATION
- Install the heat exchanger according to the illustration.
- If the heat exchanger is installed above the pool water surface, the tubes shall be placed in a loop to avoid self-drainage of the heat exchanger.
- The heat exchanger must not be covered or installed against inflammable material.
- Dosage of chlorine, acid or similar, must be done after the heat exchanger to avoid corrosion.
- If the pool circulation ceases or is shut off, the circulation pump on the primary side shall be shut off too.
- In case of climate with sub-zero temperatures, or if the pool is closed for the winter or for more than 1 month, the heat exchanger must be completely emptied.
- The heat exchanger must not be used in salt water or in pools where a chlorinator is used.
- Follow the instructions stated below:
- Chlorine content: max 3 mg/l (ppm)
- Chloride content: max 250 mg/l(ppm)
- pH-value: 7.2-7.8
- Alkalinity: 60-120 mg/l (ppm)
- Calcium hardness: 200-1000 mg/l (ppm)
- Max. temperature: 130°C
- Max. pressure: primary 10 bar, secondary 5 bar
INSTALLATION DIAGRAM