MEAN WELL IDLV-65 Series 65W IDLV Series Constant Voltage PWM LED Driver
Product Information
The IDLV-65 series is a 65W PWM Output LED Driver. It is designed to provide power and control for LED lighting applications. The driver is compliant with the IS 15885(Part 2/Sec13) standard and manufactured by Thomas Samuel. The model variations available are IDLV-65-12, IDLV-65-24, IDLV-65-36, IDLV-65-48, and IDLV-65-60.
Key Specifications:
- DC Voltage: 12V, 24V, 36V, 48V
- Rated Current : 4.2A, 2.4A, 1.8A, 1.35A
- Rated Power: 50.4W, 57.6W, 64.8W, 64.8W
- Dimming Range Output Voltage Tolerance: PWM Frequency (Typ.)
- Setup Time: 500ms / 230VAC
- Auxiliary DC Output: Nominal 12V (deviation 11.4~12.6) @50mA for A-Type only
- Voltage Range: 180 ~ 295VAC
- Frequency Range: 47 ~ 63Hz
- Power Factor (Typ.): PF>0.95/230VAC, PF>0.9/277VAC@full load
- Total Harmonic Distortion: THD<20% (@load60%/230VAC; @load75%/277VAC)
- Efficiency (Typ.): 85%, 87%, 88%, 89%, 90%
- AC Current (Typ.): 0.4A/230VAC, 0.3A/277VAC
- Inrush Current (Typ.): Cold Start 30A (twidth=270s measured at 50% Ipeak) at 230VAC
- Max. No. of PSUs on 16A Circuit Breaker: 32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC
- Leakage Current: [missing information]
Product Usage Instructions
To use the IDLV-65 series LED Driver, follow these steps:
- Ensure that the input voltage is within the specified range of 180 ~ 295VAC and the frequency is between 47 ~ 63Hz.
- Connect the LED lighting load to the appropriate DC output terminals based on the desired voltage (12V, 24V, 36V, or 48V).
- If dimming functionality is required, connect a PWM signal source to the dimming input terminals.
- If using the A-Type driver, you can utilize the auxiliary DC output by connecting a load requiring a nominal 12V with a deviation of 11.4~12.6 and consuming up to 50mA.
- Ensure that the total number of connected PSUs does not exceed the recommended limit of 32 units for a 16A circuit breaker (type B or C) at 230VAC.
- Verify that the power factor is above 0.95/230VAC or 0.9/277VAC at full load.
- Monitor the total harmonic distortion, which should be below 20% at the specified load conditions.
- Take note of the efficiency rating, which ranges from 85% to 90% depending on the model.
- Be aware of the inrush current during cold start, which can reach a maximum of 30A for a brief duration.
Please refer to the user manual for further information and safety guidelines.
Features
- Constant Voltage PM style output with frequency 1KHz
- Plastic housing with class II design
- Built-in active PFC function
- No load power consumption<0.5W(Blank-Type)
- Function options: 2 in 1 dimming (dim-to-off); Auxiliary DC output
- 3 years warranty
Applications
- LED strip lighting
- Indoor LED lighting
- LED decorative lighting
- LED architecture lighting
Description
IDLV-65 series is a 65W AC/DC LED driver featuring the constant voltage mode PWM style output design. IDLV-65 operates from 180~295VAC and offers models with different rated voltage ranging between 12V and 60V. Thanks to the high efficiency up to 90%, with the fanless design, the entire series is able to operate for -20°C~ +85°C case temperature under free air convection. IDLV-65 is equipped with various function options, such as dimming methodologies, so as to provide the design flexibility for LED lighting system.
Model Encoding
Type | Function | Note |
---|---|---|
Blank | 2 in 1 dimming (0~10VDC and 10V PWM) | In Stock |
A | 2 in 1 dimming and Auxiliary DC output | In Stock |
Specification
MODEL| IDLV-65 -12| IDLV-65 -24| IDLV-65 -36| IDLV-65
-48| IDLV-65 -60
---|---|---|---|---|---
OUTPUT
| DC VOLTAGE| 12V| 24V| 36V| 48V| 60V
RATED CURRENT| 4.2A| 2.4A| 1.8A| 1.35A| 1.08A
RATED POWER| 50.4W| 57.6W| 64.8W| 64.8W| 64.8W
DIMMING RANGE| 0~100%
VOLTAGE TOLERANCE| ±10%
PWM FREQUENCY (Typ.)| 1KHz(±20%)
SETUP TIME Note.3| 500ms / 230VAC
AUXILIARY DC OUTPUT Note.4| Nominal 12V(deviation
11.4~12.6)@50mA for A-Type only
INPUT
| VOLTAGE RANGE Note.2| 180 ~ 295VAC
(Please refer to “STATIC CHARACTERISTIC” section)
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.95/230VAC, PF>0.9/277VAC@full load
(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section)
TOTAL HARMONIC DISTORTION| THD< 20%(@load≧60%/230VAC;
@load≧75%/277VAC) (Please refer to “TOTAL HARMONIC DISTORTION” section)
EFFICIENCY (Typ.)| 85%| 87%| 88%| 89%| 90%
AC CURRENT (Typ.)| 0.4A/230VAC 0.3A/277VAC
INRUSH CURRENT(Typ.)| COLD START 30A(twidth=270 μ s measured at 50%
Ipeak) at 230VAC ; Per NEMA 410
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 32 units (circuit breaker of
type B) / 32 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.75mA / 277VAC
NO LOAD POWER CONSUMPTION| <0.5W for Blank-Type, <0.5W for
A-Type
PROTECTION
| SHORT CIRCUIT| Shut down O/P voltage, re-power on to recovery
OVER CURRENT| 105 ~ 115%
Protection type : Hiccup mode, recovers automatically after fault condition is
removed
ENVIRONMENT
| WORKING TEMP.| Tcase=-20 ~ +85℃ (Please refer to “ OUTPUT LOAD vs
TEMPERATURE” section)
MAX. CASE TEMP.| Tcase=+85℃
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 40℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X,
Y, Z axes
SAFETY & EMC
| SAFETY STANDARDS| UL8750,CSA C22.2 NO.250.13-12; BS EN/EN/AS/NZS
61347-1 & BS EN/EN/AS/NZS 61347-2-13 independent, BS EN/EN62384, BIS
IS15885(for IDLV-65-12,24,48 only), EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC
ISOLATION RESISTANCE| I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C
(@load≧60%) ; BS EN/EN61000-3-3, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS
EN/EN61547, light industry level(surge immunity:Line- Line:1KV), EAC TP TC 020
OTHERS
| MTBF| 398.7K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 1307525mm (LWH)
PACKING| 0.23Kg;54pcs/13.5Kg/ 0.96CUFT
NOTE|
- All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25°C of ambient temperature. 2. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
- Length of set up time is measured at cold first start. Turning ON/OFF the driver may lead to increase of the set up time.
- Aux. 12V will be damaged with short circuit; it will not be available with dimming off or output no load condition.
- The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify MC Directive on the complete installation again.
- The ambient temperature derating of 3.5°C/1000m with fabless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft)
* Product Liability Disclaimer: For detailed information, please refer to
https://[www.meanwell.com/serviceDisclaimer.aspx](http://www.meanwell.com/serviceDisclaimer.aspx)
DIMMING OPERATION
Dimming principle for PWM style output
- Dimming is achieved by varying the duty cycle of the output current
2 in 1 dimming function
Applying additive 0 ~ 10VDC
Applying additive 10V PWM signal (frequency range 300Hz~3KHz):
Note :
- Min. duty cycle of output current is about 8% and the output current is not defined when 0%< Iout<8%.
- The duty cycle of output current could drop down to 0% when dimming input is about 0Vdc or 10V PWM signal with 0% duty cycle.
- To ensure the dimming effect, total power must be over 45W at 100% duty cycle.
OUTPUT LOAD vs TEMPERATURE
STATIC CHARACTERISTIC
POWER FACTOR (PF) CHARACTERISTIC
TOTAL HARMONIC DISTORTION (THD)
EFFICIENCY vs LOAD
IDLV-65 series possess superior working efficiency that up to 90% can be
reached in field applications.
※ 60V Model,Tcase at 75℃
BLOCK DIAGRAM
MECHANICAL SPECIFICATION
NOTE: 2
Please use wires with a cross section of 0.75~1.5mm for TB1 and wires with a
cross section of 0.5~1.5mm for TB2.
Terminal Pin No. Assignment(TB1)
Pin No. | Assignment |
---|---|
1 | ACL |
2 | ACL |
3 | ACN |
4 | ACN |
Terminal Pin No. Assignment(TB2)
Pin No. | Assignment |
---|---|
1 | DIM+ |
2 | DIM- |
3 | Vo+ |
4 | Vo- |
A-Type
NOTE:
Please use wires with a cross section of 0.75~1.5mm for TB1 and wires with a
cross section of 0.5~1.5mm for TB2.
Terminal Pin No. Assignment(TB1)
Pin No. | Assignment |
---|---|
1 | ACL |
2 | ACL |
3 | ACN |
4 | ACN |
Terminal Pin No. Assignment(TB2)
Pin No. | Assignment | Pin No. | Assignment |
---|---|---|---|
1 | DIM+ | 4 | Vo- |
2 | DIM- | 5 | AUX+ |
3 | Vo+ | 6 | AUX- |