INERGY CUI SWI15-5-N-P5 Smart Energy Management System User Guide
- June 13, 2024
- INERGY
Table of Contents
Smart Energy Management System
SEMS Quick Start Guide
Introduction
The Inergy Systems Smart Energy Management System (SEMS) is a home automation
system that focuses on energy management and control. The SEMS connects to
energy monitoring and control devices using Z-Wave, a low-power, secure, high-
reliability mesh networking technology. Z-wave, along with other Zwave
certified devices, allows real-time monitoring of electrical power flowing
into and out of a home, generated by a solar array or a battery, and loads
such as heating and air conditioning systems, clothes dryers, electric water
heaters, and more. Additionally, the SEMS can connect to utility meters that
utilize Zigbee Smart Energy technology simplifying installation. Real-time
control is used to synchronize device operation so that energy is used
steadily and at times when electricity costs are low and renewable energy
generation is high.
The SEMS connects to Inergy Home Connect, an online and mobile app platform
that allows users to set schedules, monitor their energy usage, and control
devices, allowing for full comfort while saving energy. To achieve this, the
SEMS can also connect to Wi-Fi networks, LTE (optional), and Ethernet.
Ecosystem
The SEMS connects to the following types of home energy devices.
The SEMS connects to Inergy Home Connect (IHC) via Wi-Fi, LTE (optional) or Ethernet for real-time monitoring and control.
Package Contents
The product box contains the following items:
- SEMS hub
- AC/DC Power Adapter
- Z-wave Antenna
- LTE Antenna (optional)
Installation
Power LED:
Green – Booting.
Pulsing Blue – Operational, the unit is operating properly.
Home LED:
Blue – Operational, Blinks brighter momentarily when communicating with Z-wave
devices.
Yellow – In Z-Wave Pairing Mode (Network Inclusion/Exclusion).
Cloud LED:
Blue – Operational, Blinks brighter momentarily when communicating with IHC.
Red – The unit is not connected to the cloud – Indicate challenge with
Cellular.
Meter LED:
Blue – Operational, Blinks brighter momentarily when communicating with a
power meter.
Yellow – Operation in Progress (i.e. the unit is pairing or attempting to pair
to a meter).
Red – The unit is not paired with a meter.
Setup
Using a web browser, go to https://my.inergysystems.com/ to setup
your system and for more instructions.
In addition, download Inergy Home Connect Mobile for IOS or Android.
|
---|---
https://apps.apple.com/us/app/my-home-connect/id1462173583|
https://play.google.com/store/apps/details?id=com.inergysystems.homeconnect
Specification
Dimensions: | 5″ x 4.5″ x 1.25″ |
---|---|
Weight: | 5 oz. |
Classification: | Tabletop |
Environment: | Indoor Operational Only, 0-70°C |
Power Supply: | Included Class II Power Supply |
Model: CUI SWI15-5-N-P5 Input Voltage: 90-260 VAC Input Current: 0.5A Max
Input Frequency: 47 — 63 Hz. Integrated NEMA-1 Plug
Ports:| DC Input: 5.5MM DC Barrel, SVDC +/- 10%, 2A Maximum Wired Ethernet:
RJ-45 10 Mbps Ethernet
Standard USB-A: Not used during normal operation.
Micro-USB: Not used during normal operation.
SMA: RF Connector LTE antenna RP-SMA: RF Connector Z-Wave antenna
Important Safety Information (RF Exposure)
This equipment contains multiple radio transmitters and receivers. When it is on, it receives and transmits RF energy automatically. This equipment complies with FCC radiation and exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum of 20cm between the radiators (equipment and antennas) and your body.
FCC Statements
SEMS Model: IH40, FCC ID: 2A93L-SEMS
Contains ICs: ZGM130S & RTL8188FTV (FG6188EUFX-05)
Contains FCC IDs: XFFZ357PA20 & N7NHL7648
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
FCC Caution: Any changes or modifications not expressly approved by the
party responsible for compliance could void the user’s authority to operate
this equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in
a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.