pecron B300 B Serial Portable Power Station User Manual

June 13, 2024
pecron

pecron B300 B Serial Portable Power Station

Product Information

Product Features
Thank you for choosing the portable power station. The portable power station is widely used in mobile or outdoor fields such as ambulance, fire and rescue, emergency power, or out office as UPS.

Main functions:

  • 220V/50Hz or 110V/60Hz pure-sine wave AC output
  • UPS
  • 9V~12.6V10A DC output
  • USB-QC3.0 dual output
  • Battery display
  • LED Light
  • Solar charging

Please read the manual before using the power pack and keep it together with the proof of purchase for future reference.

Technical Specification

Model B300 B500
Rated Power 300W 500W
Peak Power 600W 1000W
Out Voltage AC pure sine wave 220V/50Hz or 110V/60Hz DC 9V~12.6V10A USB

QC3.0(5V2A 9V~12V1.5A)
Battery capacity| 288.6Wh(11.1V26Ah)| 461.76Wh(11.1V41.6Ah)
Battery Type| Lithium-ion|
Charging time| 4~5H| 6~7H
Charging voltage and current| DC12.6V 10A Solar18V AC 100~240V|
Protection Temp| Over-voltage, over-temperature overload, short-circuit 0 ~45
(Charge) -20~45 (Discharge)|
Led light| LED 1W|
Size(CM)| L34.0W18.5H6.0|
Weight(KG)| 3.2| 3.7

Product Usage Instructions

Work Environment:

  • Dry environment – Prohibited water or other liquids
  • Shady environment – Charging: 0~45°C, Discharging: -20~45°C
  • Ventilation – Leave at least 5cm space around the power pack to ensure dissipation
  • Safety – Avoid petrol, gas, and other flammable and corrosive gas environments
  • Power charging – Please pay attention to the power unit when it’s charging

Function Overview:

No. Property
1 Radiator air outlet (left and right sides)
2 Solar charging port: support to be charged through this port by

18V solar panel
3| DC output: supply 12V for appliances with an output range from 9V
to 12.6V/10A
4| LED emergency light
5| USB-QC3.0 output port*2
6| Display of battery left
7| Switch for battery volume and LED light: Single press to see
the battery volume and 5 indicating lights will light up. After
10s, the indicating lights will turn off automatically. Double
Press to turn on the LED light and double-press again to turn it
off.
8| Switch for AC output: The switch light will be blue when you
turn on the AC switch under the condition of connecting with city
power. At this time, the battery is directly from city power,
indicating that the UPS function is working. When you unplug from the
city power or there is a power cut, the power will switch to
battery power automatically. For B500, city power is preferred for
AC output.
9| AC input: AC input ends with voltage
10| AC output socket: the AC output socket is UPS output for
connecting loaded electrical equipment
11| Cooling fan

Parts List:

No. Packing list Quantity
1 Charging cable 1
2 Handbag 1
3 DC input and output cable 1+4 (optional) 1
4 Anderson to MC4 cable (optional) 1
5 Manual and warranty card 1

Product Features

Thank you for choosing the portable power station. The portable power station is widely used in mobile or outdoor fields such as ambulance, fire and rescue, emergency power or out offices such as UPS.

With main function as follows:

  • 220V/50Hz or110V/60Hz pure-sine wave AC output
  • UPS
  • 9V~12.6V10A DC output
  • USB-QC3.0 dual output
  • Battery display
  • LED Light
  • Solar charging

Please read the manual before using the power pack and put it together with proof of purchase for future reference.

Technical Specification

Model B300 B500
Rated Power 300W 500W
Peak Power 600W 1000W
Out Voltage AC pure sine wave 220V/ 50Hz or 110V/ 60Hz DC 9V~12.6V10A

USB QC3.0(5V2A 9V~12V1.5A)

Battery capacity| 288.6Wh(11.1V26Ah)| 461.76Wh(11.1V41.6Ah)
Battery Type| Lithium-ion
Charging time| 4~5H| 6~7H
Charging voltage and current| DC12.6V 10A Solar18V AC 100~240V
Protection| Over-voltage, over temperature overload, short-circruit
Temp| 0 ~45 (Charge)

-20 ~45 (Discharge)

Led light| LED 1W
Size(CM)| L34.0W18.5H6.0
Weight(KG)| 3.2| 3.7

Each Function

Please read the main characteristics of the product before using the portable power station to avoid damage.

Parts List

NO. Packing list Quantity
1 Charging cable 1
2 Handbag 1
3 DC input and output cable 1+4(optional) 1
4 Anderson to MC4 cable (optional) 1
5 Manual and warranty card 1

Control Panel

NO. Property
1 Radiator air outlet(left and right sides)
2 Solar charging port: support to be charged through this port by an 18V

solar panel.
3| Dc output:supply 12V for appliances with output range from 9V to 12.6V/10A
4| LED emergency light
5| USB-QC3.0 output port*2
6| Display of battery left
7| Switch for battery volume and LED light: Single press to see the battery volume and 5 indicating light will light after pressing it. After 10, the indicating light will turn off automatically. Double press to turn on the LED light and double-press again to turn off it.
8| Switch for AC output: The switch light will be blue when you turn on the AC switch under the condition of connecting with city power. At this time, the battery is directly from city power- indicating that the UPS function is working. When you plug out from the city power or there is a power cut, the power will switch to battery power automatically. For B500, city power is preferred for AC output.

Back

No. Property
9 AC input: AC input ends with voltage
10 AC output socket: the AC output socket is UPS output for connecting loaded

electrical equipment.
11| Cooling fan

Notice About the Function Work Environment

Dry Prohibited water or other liquids
Shady Charging: 0~ 45℃; Discharging:- 20~ 45℃
Ventilation At least 5cm space around the power pack to prove dissipation
Safety Avoid petrol, gas, and other flammable and corrosive gas environments

Power charging:

  • Please pay attention to the power unit when it’s charging. Please disconnect the charger and stop charging when the B300/B500 is fully charged.
  • Please charge the power unit every six months after no use for a long time.

AC Load:

  • The power consumption of some machines is often greater than its nominal power when started, such as an inductive load device, then it will exceed the max power of the power, so it will power off.

Warranty service

  • This product is warranted for a period 12 months, from the original date of purchase. This warranty is only valid when accompanied by the original invoice or sales receipt.

The warranty does not cover any of the following actions:

  • Unauthorized opening of the device
  • Improper package during transport
  • Improper handling, use of force or exposure to inaccurate environmental conditions
  • Improper storage
  • Misuse or ignorance of the instructions in the manual
  • Normal wear or tear

Certification

Warranty Card

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>