measurement MP 500 MP Series Flange Mount AC LVDT Owner’s Manual

June 13, 2024
measurement

measurement Logo MP Series – Flange Mount AC LVDT

MP 500 MP Series Flange Mount AC LVDT

  • measurement MP 500 MP Series Flange Mount AC LVDT - FigOperation in harsh environments
  • Mounting flanges for easy installation
  • Stroke ranges from ± 0.5 to ±10 inches
  • AC operation from 400Hz to 5kHz
  • Anodized aluminum housing
  • Screw terminal wiring
  • PTFE bore liner
  • Imperial or metric threaded core

DESCRIPTION

The MP Series LVDTs provide classic precision performance in harsh industrial environments. The rugged, extruded anodized aluminum housing contains a 100% epoxy encapsulated LVDT, affording superior environmental, mechanical and EMI/RFI protection. The convenient heavy-duty terminal strip replaces multiple lead wires thereby simplifying electrical connection, while the mounting flanges ease mechanical installation. An integral PTFE  bore liner provides a smooth, low-friction bearing surface for the core and reduces diametrical clearance.
Available in a variety of stroke ranges from ±0.5 to ±10 inches, the MP Series is the ideal choice for industrialmill type applications, power turbines, or wherever aggressive environmental conditions are present. The MPSeries is also available with a small diameter/low-mass core, for applications where excessive core weight couldinfluence the motion. The lightweight core can also reduce mechanical stresses and help preserve the structural integrity of the core actuation assembly during high speed displacement or under high vibration. The MP Seriesis compatible with the full line of Measurement Specialties LVDT signal conditioners, readouts and controllers.
Like in most of our LVDTs, the MP windings are vacuum impregnated with a specially formulated, high temperature, flexible resin, and the coil assembly is potted inside its housing with a two-component epoxy. Thisprovides excellent protection against hostile environments such as high humidity, vibration and shock.
Measurement Specialties, Inc. (NASDAQ MEAS) offers many other types of sensors and signal conditioners.
Data sheets can be downloaded from our web site at: http://www.meas- spec.com/datasheets.aspx
MEAS acquired Schaevitz Sensors and the SchaevitzTM trademark in 2000.

FEATURES

  • Rugged aluminum housing
  • 100% epoxy encapsulated
  • ±0.25% linearity (100% stroke)
  • Shock and vibration tolerant
  • Screw terminals and mounting flanges
  • Calibration certificate supplied with each unit

APPLICATIONS

  • Paper mills
  • Power turbine valve position
  • Rolling mills
  • Metal forming presses
  • Steel mill “tundish” slide valve feedback
  • Progressive rotary press Z-axis feedback

PERFORMANCE SPECIFICATIONS

ELECTRICAL SPECIFICATIONS

Parameter| MP 500| MP 1000| MP 2000| MP 3000| MP 4000| MP 5000| MP 10000
Stroke range| ±0.5
[±12.7]| ±1
[±25.4]| ±2
[±50.8]| ±3
[±76.2]| ±4
[±101.6]| ±5
[±127]| ±10
[±254]
Sensitivity, V/V/inch [mV/V/mm]| 0.7
[27.6]| 0.39
[15.4]| 0.23
[9.1]| 0.25
[9.8]| 0.20
[7.9]| 0.14
[5.5]| 0.07
[2.8]
Output at stroke ends, mV/V (*)| 350| 390| 460| 750| 800| 700| 700
Phase shift| -1°| -3°| +5°| +11°| +1°| +3°| -5°
Input impedance (PRIMARY)| 4600| 4600| 3300| 3150| 2750| 3100| 5500
Output impedance (SECONDARY)| 3750| 3200| 3000| 8300| 4000| 4000| 7500
Non-linearity| % of FR
@ 50% stroke| 0.15| 0.15| 0.15| 0.15| 0.15| 0.15| 0.15
@100% stroke (maximum)| 0.25| 0.25| 0.25| 0.25| 0.25| 0.25| 0.25
@125% stroke| 0.35| 1.00| 0 .50 ()| 0 .50 ()| 0 .50 ()| 1.00 ()| 1.00 ()
©150% stroke| 0.75| 1.30 (
)| 1.00 ()| 1.00 ()| 1.00 ()| /| /
Input voltage| 3 VRMS sine wave
Input frequency| 400Hz to 5kHz
Test frequency| 2.5kHz
Null voltage (max)| 0.5% of FRO
ENVIRONMENTAL SPECIFICATIONS & MATERIALS **

Operating temperatur| -65°F to +300°F [-55°C to 150°C]
Shock survival| 1,000 g (11ms half-sine)
Vibration tolerance| 20 g up to 2kHz
Housing material| Aluminum, anodized
Electrical connection| Six terminal barrier strip
IEC 60529 rating| IP60

Notes:
All values are nominal unless otherwise noted
Electrical specifications are for the test frequency indicated in the table
Dimensions are in inch [mm] unless otherwise noted
FR: Full Range is the stroke range, end to end; FR=2xS for ±S stroke range
FRO (Full Range Output): difference in outputs measured at the ends of the range
(*) Unit for output at stroke ends is millivolt per volt of excitation (input voltage)
(**) Requires special reduced core length

MECHANICAL SPECIFICATIONS

Parameter| MP 500| MP 1000| MP 2000| MP 3000| MP 4000| MP 5000| MP 10000
---|---|---|---|---|---|---|---
Body length “A”| 6.50 [165.1]| 7.64 [194.1]| 11.01 [279.7]| 13.85 [351.8]| 16.68 [423.7]| 18.92 [480.6]| 31.90 [810.3]
Core length “B”| 3.45 [87.6]| 4.00 [101.6]| 5.30 [134.6]| 5.60 [142.2]| 7.00 [177.8]| 7.00 [177.8]| 8.50 [215.9]
Body weight, oz [g]| 12.36 [350]| 16.59 [470]| 21.00 [595]| 26.12 [740]| 31.77 [901]| 36.18 [1026]| 60.89 [1726]
Core weight, oz [g]| 0.64 [18]| 0.74 [21]| 0.95 [27]| 0.99 [28]| 1.27 [36]| 1.27 [36]| 1.52 [43]

measurement MP 500 MP Series Flange Mount AC LVDT -
MECHANICAL

WIRING INFORMATION

measurement MP 500 MP Series Flange Mount AC LVDT -
output

ORDERING INFORMATION

Description| Model| Part Number| | Description| Model| Part Number
---|---|---|---|---|---|---
±0.5 inch LVDT| MP 500| 02560498-000| ±4 inch LVDT| MP 4000| 03560390-000
±1 inch LVDT| MP 1000| 02560499-000| ±5 inch LVDT| MP 5000| 02560502-000
±2 inch LVDT| MP 2000| 02560500-000| ±10 inch LVDT| MP 10000| 02560503-000
±3 inch LVDT| MP 3000| 02560501-000| | |
OPTIONS
5.0 KHz calibration (Available on MP 500 only)| 02560498-002
Metric threaded core (M4 x 0.7)| xxxxxxxx-006
Small-diameter/low-mass core (consult factory for mass and dimensions)| xxxxxxxx-020

Note: Add multiple option dash numbers together to determine proper ordering suffix
Example: MP 1000, ±1.0 inch, with 5 KHz calibration and metric core, P/N 02560499-008

ACCESSORIES

Core connecting rod,  6 inches long, 6-40 threads| 05282947-006
Core connecting rod,  12 inches long, 6-40 threads| 05282947-012
Core connecting rod,  24 inches long, 6-40 threads| 05282947-024
Core connecting rod,  36 inches long, 6-40 threads| 05282947-036
Core connecting rod,  6 inches long, M4x0.7 metric threads| 05282978-006
Core connecting rod,  12 inches long, M4x0.7 metric threads| 05282978-012
Interconnect cable for IEM-422 signal conditioner, stripped & tinned to PTO6A-10-6P connector (1)| 04290594-000

(1) Cables are shielded, 10 foot long, and are rated 80°C [176°F] operating. Consult factory for other lengths.
Refer to our “ Accessories for LVDTs” data sheet for our LVDT signal conditioning instrumentation and other accessories.

TECHNICAL CONTACT INFORMATION

NORTH AMERICA EUROPE ASIA

Measurement Specialties, Inc.
1000 Lucas Way
Hampton, VA 23666
United States
Phone: +1-800-745-8008
Fax: +1-757-766-4297
Email: sales@meas-spec.com
Web: www.meas-spec.com| MEAS Deutschland GmbH
Hauert 13
D-44227 Dortmund
Germany
Phone: +49-(0)231-9740-0
Fax: +49-(0)231-9740-20
Email: info.de@meas-spec.com
Web: www.meas-spec.com| Measurement Specialties China Ltd.
No. 26, Langshan Road
High-tech Park (North)
Nanshan District, Shenzhen 518057
China
Phone: +86-755-33305088
Fax: +86-755-33305099
Email: info.cn@meas-spec.com
Web: www.meas-spec.com

The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent rights to  the manufacturer. Measurement Specialties, Inc. reserves the right to make changes without further notice to any product herein. Measurement Specialties, Inc. makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does Measurement Specialties, Inc. assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different applications. All operating parameters must be validated for each customer application by customer’s technical experts. Measurement Specialties, Inc. does not convey any license under its patent rights nor the rights of others.