AQUAPHOR 100 GPD Pressure Boosting Unit Instruction Manual

June 13, 2024
AQUAPHOR

AQUAPHOR 100 GPD Pressure Boosting Unit

AQUAPHOR-100-GPD-Pressure-Boosting-Unit-PRODUCT

Product Information
The Pressure Boosting Unit is a device designed for use with all Aquaphor reverse osmosis systems. It is used to increase water pressure and filtration rate in the water purifier. The unit comes with a set of tubes and fittings, as well as a power supply unit. The pressure-boosting unit operates from the main power supply and automatically turns off when not in use. It also includes a pressure reducer with a tube, which is required for safe operation in case of a sudden increase in water pressure.

Delivery Set

  • 1 Pressure boosting unit assembled
  • Set of tubes and fittings:
    • Tube 1/4 (1.2 meters), blue color
    • Pressure reducer with tube
    • Three-way valve with tube
    • Restrictor 50 gallon
  • 1 Power supply unit*

Technical Characteristics

  • Weight: 1.7 kg
  • Main characteristics of the power supply unit:
    • Input voltage
    • Input plug mounted in the CEE
    • Output voltage
    • Output current
    • The output connector is coaxial
    • Wire length, not less than

Please note that the Pressure boosting unit, its power supply, power cord, and plug should not be immersed in water or other liquids. They should not be washed under running water or in the dishwasher. To avoid electric shock, do not touch the Pressure boosting unit or its components with wet hands. Do not disassemble the unit or attempt to repair it yourself. If any malfunction is detected, disconnect the power supply from the mains and contact customer service.

Product Usage Instructions
Installation
It is recommended to contact Aquaphor customer service or Aquaphor regional dealers for the connection of the Pressure Boosting Unit to the water purifier. The manufacturer is not responsible for any improper installation or resulting damages.

  1. Select an appropriate location for the Pressure Boosting Unit. Ensure that the connecting tubes are loose and not bent. Fix the free sections of the tubes to prevent damage from other objects.
  2. Place the water filter at a distance or isolate it from heat sources such as kitchen ovens, boilers, hot water supply pipes, dishwashers, or washing machines. Ensure that water cannot enter the housing of the Pressure Boosting Unit and the power supply unit.

Tube Connection
To connect the tubes:

  1. Remove the stopping clip from under the plastic sleeve.
  2. Insert the pre-wetted end of the tube into the sleeve of the fitting until it stops at a depth of about 15 mm.
  3. Insert the clip to secure the tube.
  4. Check the strength of the fastening by applying a force of 8-10 kgf. The tube should not be pulled out.

DELIVERY SET

AQUAPHOR-100-GPD-Pressure-Boosting-Unit-FIG-1

  1. Pressure boosting unit assembled 1pc.
  2. Set of tubes and fittings:
    • Tube 1/4 “ (1.2 meters), blue color 1 pc.
    • Pressure reducer with tube 1 pc.
    • Three-way valve with tube 1 pc.
    • Restrictor 50 gallon 1 pc.
  3. Power supply unit* 1 pc.

ТECHNICAL CHARACTERISTICS

Size (length × width × height) 230 × 121 × 76 mm
Minimum pressure in the water supply network 0.05 MPa (0.5 at)
Maximum pressure in the water supply network, no more than 0.63 MPa (6.5 at)
Water temperature from +5 to +38 °C
Pressure boosting unit power supply 24 V ± 5%, at least 1.5 A DC
Weight, not more than 1.7 kg

Main characteristics of the power supply unit

Input voltage 100–240 V AC
Input plug mounted in the CEE 7/16 unit
Output voltage 24 V DC
Output current 1.5 A
The output connector is coaxial, Ø 2.5 × Ø 5.5 mm
Wire length, not less than 1.0 m

Electrical Power Supply

Before connecting the Pressure boosting unit to the power supply, check that the power supply voltage corresponds to the parameters specified in the Pressure boosting unit Manual. Use only a power supply with the output characteristics specified in this manual (24 V ± 5%, at least 1.5 A DC). Before installing the Pressure boosting unit, make sure that it will be protected from freezing, water ingress, direct sunlight, and contact with hot objects, including hot water pipes, radiators, and heating devices. Protect from shocks and fallings. The cord of the power supply connected to the Pressure boosting unit must not be stretched. Make sure that the power cord does not touch surfaces that can damage it. Do not immerse the Pressure boosting unit, its power supply, the power cord and the plug in water or other liquid. Do not wash them under running water or in the dishwasher. To avoid electric shock, do not touch the Pressure boosting unit connected to the power supply, the power supply unit, its power cord, and plug with wet hands. Do not allow contamination of the Pressure boosting unit housing. If necessary, wipe it with a dry cloth, after disconnecting the Pressure boosting unit from the power supply.

Do not disassemble the Pressure boosting unit or open its housing!
Do not use the Pressure boosting unit and the power supply if problems or damage to the wire are detected. Do not attempt to repair the device yourself. If any malfunction is detected, first disconnect the power supply from the mains, then disconnect it from the Pressure boosting unit. Contact customer service.

INSTALLATION

Attention! It is not recommended to connect the Pressure boosting unit to the water purifier yourself. To connect the Pressure boosting unit, it is recommended to contact Aquaphor customer service or Aqua-phor regional dealers.
The manufacturer is not responsible for the improper quality of the work on connecting the Pressure boosting unit to the water filter, as well as for the result of this work. Responsibility for the shortcomings of this work, as well as for causing harm to the health or property of the customer or other people as a result of these shortcomings, is borne by the party performing the installation. Select the appropriate location for the Pressure boosting unit. Note that the connecting tubes should be loose and not bent. The free sections of the tubes should be fixed so that they cannot be damaged by other objects. The water filter must be placed at a distance or isolated from any heat sources (kitchen ovens, boilers, hot water supply pipes, dishwashers or washing machines, etc.) and placed in a place that prevents water from entering the housing of the Pressure boosting unit and the power supply unit.

How to connect the tubes
Remove the stopping clip from under the plastic sleeve, insert the pre-wetted end of the tube into the sleeve of the fitting until it stops at a depth of about 15 mm and insert the clip. Check the strength of the fastening of the tube: at a force of 8-10 kgf, the tube should not be pulled out.

How to disconnect the tubes
To disconnect the tube, pull out the stopping clip from under the plastic sleeve and, pressing the end of the plastic sleeve, pull out the tube.

CONNECTING THE PRESSURE BOOSTING UNIT TO AQUAPHOR MORION RO-101S AND RO-101 DRINKING WATER MACHINES (FIG. 1)

  • Turn off the water supply to the water purifier (close the tap of the connection node).
  • Relieve the pressure in the RO according to the manual for your RO.
  • Remove the RO cover.
  • Remove the plug from the fitting (11).
  • Disconnect the tube included in the RO kit from the connections (2) and (6).
  • Disconnect the tube (9) from the fitting (8).
  • Connect the assembled Pressure reducer with a pipe (1), supplied with the Pressure boosting unit, to the nozzle (2). Then connect white tube JG (in) (3A) to the free outlet of the reducer (1) after passing it through the process hole (4) in the console. Note that the tube should pass without sharp bends and kinks!
  • Connect white tube JG (out) (3B) to the fitting (6) after passing it through the process hole (4) in the console. Note that the tube should pass without sharp bends and kinks!
  • Connect the assembled tee with the tube (7), which is included in the Pressure boosting unit kit, to the fitting (8). Then connect the JG tube (9), which is part of the RO circuit and exits the storage tank, to the tee (7).
  • Connect one end of the blue JG tube (3C), included in the Pressure boosting unit kit, to the free outlet of the tee (7) after passing it through the process hole (10) in the console. Connect the second end of the tube to the fitting (11). Note that the tube should pass without sharp bends and kinks!
  • Disconnect the membrane drainage tube and replace the restrictor with the one included in the Pressure boosting unit kit. Connect the membrane drainage tube. Put the RO cover back on.

CONNECTING THE PRESSURE BOOSTING UNIT TO AQUAPHOR MORION RO-70 DRINKING WATER MACHINES (FIG. 2)

  • Turn off the water supply to the water purifier (close the tap of the connection node).
  • Relieve the pressure in the RO according to the manual for your RO.
  • Remove the RO cover.
  • Remove the plug from the fitting (12).
  • Disconnect the tube included in the RO kit from the connections (2) and (6).
  • Disconnect the tube (9) from the fitting (8).
  • Connect the assembled Pressure reducer with a pipe (1), supplied with the Pressure boosting unit, to the nozzle (2). Then connect white tube JG (in) (3A) to the free outlet of the reducer (1) after passing it through the process hole (4) in the console. Note that the tube should pass without sharp bends and kinks!
  • Connect white tube JG (out) (3B) to the fitting (6) after passing it through the process hole (4) in the console. Note that the tube should pass without sharp bends and kinks!
  • Connect the assembled tee with the tube (7), which is included in the Pressure boosting unit kit, to the fitting (8). Then connect the JG tube (9) which is part of the RO circuit and exit the check valve, to the tee (7).
  • Connect one end of the blue JG tube (3C), included in the Pressure boosting unit kit, to the free outlet of the tee (7) after passing it through the process hole (11) in the console. Connect the second end of the tube to the fitting (12). Note that the tube should pass without sharp bends and kinks!
  • Disconnect the membrane drainage tube and replace the restrictor with the one included in the Pres-sure boosting unit kit. Connect the membrane drainage tube.
  • Put the RO cover back on.

COMMISSIONING

  • Connect the power supply to the Pressure-boosting unit
  • Plug the power supply into an outlet
  • Turn on the water supply to the water purifier (open the tap of the connection node). After passing the Pressure boosting unit and water purifying system, water will begin to flow into the storage tank (or jug). The Pressure boosting unit will switch off when the storage tank (or jug) is full.

OPERATION

The Pressure boosting unit is fully assembled, tested, and ready for operation.
ATTENTION! The Pressure boosting unit is adjusted and does not require further adjustments. The manufacturer is not responsible for changing the Pressure-boosting unit settings.
ATTENTION! The service life of the Pressure boosting unit directly depends on the operability of the water purifier cartridges, it is very important to replace the filtering cartridges in time.
ATTENTION! To increase the service life of the Pressure boosting unit in Aquaphor Morion RO-101, RO-70 uses pre-treatment systems (purchased separately) to reduce the risk of mechanical debris from the main water supply. During the first week of operation, check the Pressure boosting unit daily for leaks. Do not allow the Pressure boosting unit to work at a pressure in the water supply greater than 0.63 MPa (6.5 at).

The operating temperature is from +5 to +38 °C. If the characteristics of the source water significantly exceed the requirements of national standards for drinking water, we recommend that you install additional water treatment systems (mechanical cleaning systems, etc.). Use a water purifier with the Pressure boosting unit only for cleaning water from the cold water supply system. Disposal in accordance with environmental, sanitary, and other requirements established by national standards in the field of environmental protection and ensuring the sanitary and epidemiological well-being of the population.

MANUFACTURER WARRANTY

The service life of the Pressure boosting unit is 5 years from the manufacturing date. The Pressure boosting unit shall be replaced upon expiration of the service life. The shelf life of the Pressure boosting unit before an operation is a maximum of 3 years at temperatures from +5 to + 38 °C, without removing the packaging.
Warranty period**** of the Pressure boosting unit is 1 year from the purchase date. The purchase date of the Pressure boosting unit is the date of the retailer’s stamp in this manual or the date of the sales receipt. The manufacturer shall bear no warranty if this manual containing the date of sale is lost and there are no other ways to determine the period of the product operation.
Please contact the retailer or the manufacturer in case of any claims to the operation of the Pressure boosting unit. The manufacturer shall bear no responsibility in any of the following cases:

  • the consumer does not follow installation instructions described in this manual for the Pressure boost-ing unit and connecting it to the water purifier of the certain model;
  • the consumer does not follow the water purifier installation instructions described in the manual for a water purifier used with the Pressure boosting unit;
  • The pressure boosting unit is connected and used with water purifiers other than those specified in this manual;
  • The pressure boosting unit is used beyond the limits set by the technical specifications in this manual.

TROUBLESHOOTING

Fault Problem Solution
The pump does not turn on Insufficient water pressure in the main water
supply Contact the plumbing service
Not detected Contact customer service
The pump does not turn off The drinking water tap is open Close the drinking

water tap
Not detected| Contact customer service
Water tank not fill- ing quick enough| Water purifier cartridges are clogged| Replace water purifier cartridges
Not detected| Contact customer service

In case of any other faults contact customer service!

  • Regardless of the operation starting date.
  • The manufacturing date is the date in the format DD.MM.It is shown by the manufacturer on the label placed on the housing.
  • Using the Pressure boosting unit beyond its service life may result in harm to the health or property of the consumer or other persons and must be discontinued.
  • The period during which the manufacturer must satisfy the customer’s claims in case of faults in the product.

Figure 1. Connection diagram of the Pressure boosting unit
to the Aquaphor Morion RO-101S and RO-101 drinking water machines

AQUAPHOR-100-GPD-Pressure-Boosting-Unit-FIG-4

Figure 2. Connection diagram of the Pressure boosting unit
to the Aquaphor Morion RO-70S and RO-70 drinking water machines

AQUAPHOR-100-GPD-Pressure-Boosting-Unit-FIG-5

PRESSURE BOOSTING UNIT (100 GPD)
Manufacturer: Aquaphor International OÜ, L. Tolstoi 2A, Sillamäe, Estonia, 40231. The manufacturer reserves the right to make improvements to the design of the Pressure boosting unit without reflecting them in the passport.
Date of manufacture and quality control

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals