Lightspeed NQ-S1810CT-G2 Bogen VoIP Speaker Interface Instructions
- June 10, 2024
- lightspeed
Table of Contents
Lightspeed NQ-S1810CT-G2 Bogen VoIP Speaker Interface Instructions
The following shows how to interface the Lightspeed 975 and Topcat Instructional Audio systems together with the NQS1810CT-G2 or NQ S1810WT-G2 VoIP Speakers in combination with an NQ-E7010 I/O Controller on Bogen’s Nyquist E7000 system. These simple interfaces enable key functionality including a mobile solution for the teacher to initiate an alert in the classroom directly from the pendant microphone.
ALERT NOTIFICATION
An alert notification through the Bogen Nyquist paging & intercom system can be initiated from the Lightspeed Flexmike pendant microphone worn by the teacher. A simple connection from the Lightspeed 975 or Topcat to the Bogen NQ-E7010 is all that’s required. Connect from the “Contact Closure” output on the Lightspeed 975/Topcat to an Input (Input Pin & GND) on the Bogen NQ-E7010 I/O Controller and configure the rules for that input to trigger a Routines based Emergency Call for the classroom when activated. A single NQ-E7010 can service up to 8 classrooms in this fashion.
Once connected and configured, the teacher simultaneously presses and holds the volume up/down buttons on the microphone for 3 seconds. The 975 or Topcat sends the signal to the Bogen NQ-7010 via the contact closure and the Flexmike mode light will begin flashing for a few seconds to tell the teacher the alert was activated.
OVERHEAD PAGE/INTERCOM CALL MUTE
Lightspeed’s 975 and Topcat systems can be configured to mute all audio when an overhead page or intercom call comes through from the Bogen Nyquist system. Once the paging/intercom audio begins, all audio from the 975 or Topcat, including the teacher and student microphones (as well as any multimedia audio) will be muted to ensure the page/intercom call is clearly heard by everyone in the classroom. Connect from the “COM” and “NO” terminals on the Bogen Nyquist speaker’s VoIP module to the “Relay Input” on the 975 or Topcat system. Once an audio signal is detected from the Bogen system it will send a relay signal to the 975 or Topcat to mute all audio coming through the Lightspeed speaker (microphones and connected multimedia). Once the announcement or call through the Bogen system ends, the Lightspeed system will un-mute, resuming all regular audio.
The following shows how to interface the Lightspeed 975 and Topcat Instructional Audio systems together with the NQ-GA10P on Bogen’s Nyquist E7000 system. These simple interfaces enable key functionality including a mobile solution for the teacher to initiate an alert in the classroom directly from the pendant microphone.
ALERT NOTIFICATION
An alert notification* through the Bogen Nyquist paging & intercom system can
be initiated from the Lightspeed Flexmike pendant microphone worn by the
teacher. A simple connection from the Lightspeed 975 or Topcat to the Bogen
NQ-GA10P is all that’s required. Connect from the “Contact Closure” output on
the Lightspeed 975/ Topcat to the “G” and “A” call switch terminals on the
Bogen NQ-GA10P VoIP Intercom Module.
Once connected, the teacher simultaneously presses and holds the volume up/down buttons on the microphone for 3 seconds. The 975 or Topcat sends the signal to the Bogen NQ-GA10P via the contact closure and the Flexmike mode light will begin flashing for a few seconds to tell the teacher the alert was activated.
Note: The alert notification will result in an intercom call to the Admin Station assigned to the classroom. The status level of that intercom call (Normal / Urgent / Emergency) is determined by the “Call in Level” configured in the Class of Service (CoS) profile for that classroom
OVERHEAD PAGE/INTERCOM CALL MUTE
Lightspeed’s 975 and Topcat systems can be configured to mute all audio when
an overhead page or intercom call comes through from the Bogen Nyquist system.
Once the paging/intercom audio begins, all audio from the 975 or Topcat,
including the teacher and student microphones (as well as any multimedia
audio) will be muted to ensure the page/intercom call is clearly heard by
everyone in the classroom. Connect from the RELAY “COM” and “NO” terminals on
the Bogen NQ-GA10P Intercom module to the “Relay Input” onthe 975 or Topcat
system. Once an audio signal is detected from the Bogen system it will send a
relay signal to the 975 or Topcat to mute all audio coming through the
Lightspeed speaker (microphones and connected multimedia). Once the
announcement or call through the Bogen system ends, the Lightspeed system will
un-mute, resuming all regular audio.
The following shows how to interface the Lightspeed 975 and Topcat Instructional Audio systems together with the NQ-E7030 ASB on Bogen’s Nyquist E7000 system. These simple interfaces enable key functionality including a mobile solution for the teacher to initiate an alert in the classroom directly from the pendant microphone.
ALERT NOTIFICATION
An alert notification* through the Bogen Nyquist paging & intercom system can
be initiated from the Lightspeed Flexmike pendant microphone worn by the
teacher. A simple connection from the Lightspeed 975 or Topcat to the Bogen
NQ-E7030 is all that’s required. Connect from the “Contact Closure” output on
the Lightspeed 975/ Topcat to the “A” and “G” terminals on the Bogen NQ-E7030
Analog Station Bridge station port associated with the classroom.
Once connected, the teacher simultaneously presses and holds the volume up/down buttons on the microphone for 3 seconds. The 975 or Topcat sends the signal to the Bogen NQ-E7030 via the contact closure and the Flexmike mode light will begin flashing for a few seconds to tell the teacher the alert was activated.
*Note: The alert notification will result in an intercom call to the Admin Station assigned to the classroom. The status level of that intercom call (Normal / Urgent / Emergency) is determined by the “Call in Level” configured in the Class of Service (CoS) profile for that classroom.
25V PAGE/INTERCOM PRIORITY MUTE
Lightspeed’s 975 or Topcat systems can be interfaced with a 25V paging speaker
to detect an audio signal during a page or intercom call and then mute all
other audio. Once the paging/ intercom audio begins, all audio from the 975 or
Topcat, including the teacher and student microphones (as well as any
multimedia audio) will be muted to ensure the page/intercom call is clearly
heard by everyone in the classroom. Hang the Lightspeed PageFirst sensor clip
on the 25V speaker wire between the Bogen NQ-E7030 and the paging/intercom
speaker(s). Wire the PageFirst sensor clip back to the Lightspeed 975 or
Topcat system, connecting to the PageFirst terminals. Test the system to
ensure it mutes properly and adjust the sensitivity on the 975 or Topcat as
needed. Once an audio signal is detected along the 25V line, the 975 or Topcat
will mute all audio coming through the Lightspeed speaker (microphones and
connected multimedia). Once the announcement or call through the Bogen system
ends, the Lightspeed system will un-mute, resuming all regular audio.