Honeywell R200S-N3 Interconnected Smoke Alarm Installation Guide

June 13, 2024
Honeywell

Honeywell Logo R200S-N3 Interconnected Smoke Alarm
Installation and User Guide

R200S-N3 Interconnected Smoke Alarm

Honeywell R200S-N3 Interconnected Smoke Alarm Manual R200S-N3 version: 6

| ×| 0|
---|---|---|---
Recommended| Not recommended| Use heat alarm| R200H
Honeywell R200S-N3 Interconnected Smoke Alarm - Fig| Honeywell R200S-N3 Interconnected Smoke Alarm -
Fig1
---|---
Honeywell R200S-N3 Interconnected Smoke Alarm - Fig 2| Honeywell R200S-N3 Interconnected Smoke Alarm - Fig
3

Introduction

Thank you for purchasing Resideo R200S-N3 interconnected smoke alarm. This product is suitable for indoor installation in domestic premises, including static holiday homes and caravans. This manual contains important safety information about the installation and operation of the alarm. Please read the manual carefully and keep it in a safe place for future reference.

Where to install the device? (refer page 2)

Refer to page 2 for guidance. Please ensure that you also follow country- specific regulations and guidelines, such as: British BS5839-6 or German DIN14676. If in doubt, please check, for example by contacting your local Fire Service.

Where not to install the device

  • In an environment with a risk of draught (e.g. close to air conditioning, fans, ventilation outlets).
  • In areas where steam or fumes are emitted, e.g. kitchens: use R200H-N1 (alarm with heat sensor) instead.

NOTE: To avoid sensor contamination, the smoke alarm should be removed from the mounting for the duration of any building work involving dust or debris. If this is not possible, the alarm vents must be fully covered with a brightly colored plastic bag or tape to reduce the risk of leaving covered when works are completed. When covered, the alarm will not detect fires or smoke, so remove the covering when the work is completed each day and replace it the following day if necessary.

Installation (refer to pages 3 and 4 for guidance)

WARNING: The alarm contains a permanently sealed, non-replaceable battery, and does not contain serviceable parts inside. Any attempt to open or repair it creates a risk of electric shock or malfunction.

Activation (refer page 4)

Before commissioning the smoke alarm, it is important to activate and test it for correct operation:

  • If you need to enable the tamper proof locking feature, break off or cut off the small cylinder ①.
  • Install the alarm in its mounting bracket ② and twist until it clicks ③. The LED indicators will flash once and emit a beep.
  • The entire surface of the alarm cover is the test/silence button. Press it firmly for at least 3 seconds ④. The alarm will emit 3 short beeps with LED flash at the same pace.
  • Release the button. The alarm may beep for a few more seconds, to confirming it’s been activated.

Removal (refer to page 4, picture ⑤)

Once the plastic pin is cut and the mounting plate is subsequently mounted, the function is enabled. To disassemble the alarm, take a screwdriver and push it into the mounting hole ⑤. Then rotate the alarm counterclockwise to remove the alarm from the  mounting plate.

Practice fire safety

If the alarm sounds, and you have not pushed the test button, it may be warning of a dangerous situation and your immediate response is necessary. If you are in any doubt regarding the cause of an alarm it should be assumed that the alarm is due to an actual fire and the dwelling should be evacuated. Expose everyone to the sound of a smoke alarm and explain what the sound means. Develop family escape plans, discuss them with all household members, and practice them regularly. Determine the exits from each  room and an escape route to the outside from each exit. Teach all household members to touch the door and use an alternate exit when the door is hot. Teach household members to crawl along the floor to stay below smoke and dangerous gases. Establish a safe meeting place outside the building.

Recommended actions when the alarm is activated

Raise the alarm by shouting: “Fire! Fire! Fire!”, or by banging metal objects together.
Evacuate immediately, using the nearest fire exit. Do not stop to investigate the fire or to collect valuables or pets. Use your escape route to get everyone out and meet at an agreed point. Along the way, close any open doors, and only open the doors you need to go through. Check doors and handles with the back of your hand. If they feel warm, don’t open the door. If there is a lot of smoke, crawl along the floor as the air and visibility will be better. Once you’ve got everyone out of the building, call the Fire Brigade from  any phone. Give the operator your name and address. Don’t go back into the building for anything. If there is still someone inside, tell firefighters when they arrive – they will be able to find the person quicker and more safely than you. Find somewhere safe to wait for the Fire Brigade. When they arrive, try to give them as much information as possible about the fire and building.
Note: These guidelines will assist you in the event of a fire, however, to reduce the chance that fires will start, practice fire safety rules and prevent hazardous situations.

Visual & acoustic signals

Operating mode| Visual (flash)| Acoustic (beep)| Description
---|---|---|---
Normal| 1 x per 48 seconds| None| Device is functioning properly
Test| 1 x per second (4 x)| 1 x per second (3 x) /
pause of 1,5 seconds| Device is testing by press the test/silence button for 3 seconds
Alarm for smoke| 1 x per second (4 x)| 1 x per second (3 x) /
pause of 1,5 seconds| Device is detecting smoke
Alarm silence| 1 x per 8 seconds| None| If the Alarm signal is muted, lasting for approx. 10 minutes
Low battery warning| 2 x per 48 seconds| 1 x per 48 seconds| Battery is running low, replace the smoke detector with a new one.
Low battery/Sensor fault warning silence| 1 x per 48 seconds| None| If Low battery/Sensor fault warning is muted, lasting for approx. 8-10 hours
Sensor fault warning| 2 x per 48 seconds| None| Sensor is not functioning properly, see 11. Maintenance
Interconnected alarm| None| 1 x per second (3 x) /
pause of 1,5 seconds| Device received remote alarm from other device.
End of life warning| 3 x per 48 seconds| 3 x per 48 seconds| The device is end of life, replace the smoke detector with a new one.
Wireless interconnecting| Continuously on| None| Device is sending or searching for wireless signal
| HOW TO MUTE ALARMSOUND|
Alarm/Low battery/Sensor fault silence| ONLY AFTER RECOMMENDED ACTIONS HAVE BEEN TAKEN| Press cover test/silence button for 3 seconds

If the alarm fails to operate or you have a “fault warning” the advice of the manufacturer should be sought.

Wireless functions (see page 5)

Interconnect your alarms
a) Place the interconnected alarms as close as possible, not further than 5 meters apart.
b) Choose one interconnected alarm as Master. Press 3 times its test/silence button. TLED light will turn on.
c) Choose another interconnected alarm as Slave. Press 3 times its test/silence buttonLED light will turn on.
d) Wait a few seconds until the Master device beeps and Slave device turns off its LED,indicating successful network pairing.
e) Repeat step c) for connecting more interconnected alarms.
NOTE: always use the same Master alarm for connecting additional Resideo interconnected smoke, heat or carbon monoxide (CO) alarms, now and in future. Write down which interconnected alarm in your home is the Master. And you can only enable pairing when the mounting plate has installed.
After the master alarm enters interconnect mode for pairing, it will automatically exit connection mode within 40 seconds, and this 40-second period will be extended by another 40 seconds after each successful pairing. After all interconnected alarms are connected, the master can also manually exit by pressing the test/silence button three times if the master device has not yet exited the pairing mode.
Test your interconnection
Hold down the test/silence button. The initial interconnected alarm will beep continuously with the LED flashes at the same rate. Other interconnected alarms in the network will receive the signal after few seconds, and they will beep continuously without LED flashes forat most two test alarm period.
Reset Connection
a) Remove the product out of the back plate, and you will hear a beep in few seconds.
b) 3x Press the test/silence button and press once again when LED light turn on.
c) While the LED light turn off with a beep, the connection has been reset successfully.
How to silence interconnected alarms
When an interconnected alarm has been activated, find the originating interconnected alarm, which will be the one both emitting the audio signal and red LED message. Mute this interconnected alarm by pressing its test/silence button, and within 40 seconds the remaining interconnected alarms will go back to standby.
Note: if you press the test/silence button on one of the interconnected alarm other than the originating alarm, it will NOT be silenced, the remaining interconnected alarms will continue emitting sound until the primary alarm is stopped.

Maintenance

This smoke alarm is equipped with a self-testing mechanism. Additionally, we recommend testing the smoke alarm manually at least once per months by pressing the test/silence button. If the smoke alarm functions correctly, it will generate a loud beep. Due to the loudness of the alarm, make sure that you always stand at arm’s length distance from the unit when testing. If the smoke alarm does not generate the acoustic signal, it must be replaced immediately. Clean the smoke alarm at least once per month to remove  dirt, dust or debris. Use a vacuum cleaner with a soft brush and vacuum all sides of the alarm. Do not remove the top cover to clean it inside. The alarm does not contain any serviceable parts inside – do not attempt to open or repair it. If the alarm shows any signs of damage, it must be replaced.

Warnings

This Smoke alarm is for indoor use only. To prevent injury, this smoke alarm must be securely attached to a ceiling/wall in accordance with the installation instructions. Do not paint or cover the Smoke alarm. This Smoke alarm should not be exposed to  xcessive heat such as sunshine, fire, etc. Do not test with flame – this can set fire to the Smoke alarm and damage the house. Do not test with smoke, as the results can be misleading, unless special equipment is used. Prolonged exposure to low or high temperatures, or high humidity, may  reduce battery life. Prolonged periods of alarm will reduce battery life. The latest design,materials and manufacturing techniques have been used in the construction of this Smoke alarm to minimize the risk of its contamination by dust,  insects, etc. However, it is impossible to completely eliminate such risk, so ensure that the Smoke alarm is clean, and dust does not build up. Any insects or cobwebs in the vicinity of the Smoke alarm should be promptly removed. In certain circumstances, even with regular cleaning, contamination can build up in the sensor, triggering the alarm. If this happens, the Smoke alarm must be replaced.

Specifications

Detection method :  Optical sensor
Power supply :  Sealed battery 3 V DC (included)
Battery lifetime :  10 years
Alarm volume :  ≥ 85 dB (A) at 3 meters
Alarm sensitivity :  0,12 – 0,19 dB/m
Operating temperature :   0°C – 40°C
Operating humidity :  < 93%
Date of replacement :  See product label (“mm yyyy” format)
Individual alarm indicator :  Yes
Alarm silence feature :  Yes
Low battery warning :  Yes
Low battery silence feature :  Yes
Installation in leisure accommodation vehicles :  Yes
Mounting location :  Ceiling or wall
Interconnectable :  Yes
Interconnection :  Maximum 12 alarms
Wireless frequency :  868 MHz
TX power :  8dbm
Complies with :  EN 14604:2005 + AC:2008
Product net weight :  153 g
Product dimension :  ø 104 x 41.4 mm

Service and contact

For questions about the installation, use or operation of this product please visit www.resideo.com Please note: while every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract.

Disposal and regulatory compliance

This product complies with the Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC. When the unit has come to the end of its life, dispose of it in accordance with local regulations. It is classified as electronic waste and contains a battery and therefore should be disposed of separately from household waste.
This smoke alarm is certified by CNPP CERT to the European standard EN 14604, the identification number 1116. It conforms to the General Product Safety Directive (GPSD), the Electromagnetic Compatibility Directive (EMC), the Construction Products Regulation (CPR) and the Restriction of Hazardous Substances Directive (RoHS) and the Radio Equipment Directive (RED).

Disclaimer

This smoke alarm is designed to alert you to a potentially dangerous fire. It is not designed to  remedy a fire problem nor to locate a specific source of fire. Resideo shall not be liable topay for any fire investigation or service call carried out or arranged in response to an alarm.

RESIDEO’S 10 YEAR WARRANTY POLICY

R100C-1, R200C-1, R200C-2, R200C-3, R200C-N1, R200C-N2, R200C-N3, R200H-N1, R200H-N2, R200S- 1,R200S-2, R200S-3, R200S-N1, R200S-N2, R200S- N3, R200ST-N1, R200ST-N2, R200C2-A, R200C2-A-UK, R200C2-B, R200C2-E,
Beneficiary of this Warranty
This limited warranty ts pravided te its direct custamer (Buyer) by the member of the Resideo Fechnologies. Inc group of companies (Resideo”} which sells the product. Residee does nat provide this warranty to the can- sumer or end-user af the product. Resideo expects that Buyer will give its customers an equivalent warranty to that given by Resideo to Buyer here- under. This does not affect any statutory abligations that Residea may have to cansumers as manufacturer of the Praducts. Resedeo reserves the nght, at its discretion, to change these Warranty Terms and the preducts ta which these Warranty [erms apply. Any changes te these Warranty Terms only apply to Products sold after the date of the change.
Resideo’s Warranty
Resideo warrants that the Products will be free from defective materials and faulty watkmanship and conform ta applicable specifications for a period of 120 months from the manufacturing date code on the Product. lf any Praduct becomes defective during the applicable warranty period fara treason that is nat excluded below, Ressdeo will, at its sale optian, el- ther repair or replace free of charge with a new or refurbished product of credit to Buyer’s account the pnce paid for the Praduct, Residea will nat be responsible for any of Buyer’s costs of de-installing and reinstalling the Product. travel or any other costs.
Exclusions from the Warranty
This warranty is an extended manufacturer’s warranty and to the extent permitted by law, is in lieu of all other wasranties and conditions, ex- pressed or implied including those of satisfactory quality or fitness for a particular purpose. Residea shall have no ebligaton under this warranty orotherwise if: } The preduct is not installed in accordance with Resideo’s installation instructions and applicable installation standards, is not used far a purpose far which it is designed and in accordance with Residea’s user instructions or is not maintained in accordance with Resideo’s care and maintenance instructions oris altered {including the alteration af any serial number), senwed or repaired by anyone other than Resideo/Resideo’s Authorized Service/Repair Centre: ii)  Damage is  caused by outside occurrences, such as lightning, power surges, fire,floods, acts of nature, of the like or quality of water, aris caused by misuse, or vandalism; or ai) A defact is not caused by reason af defective materials or workmanshup. wv) [his watranty daes not cover the re-changeable bat- tery used in R200C2-A, R200C2-A-UK, R200C2-B, R200C2-E. This wartanty does not cover the costs of replacing consumable items (such as batteries), maintenance checks and adjustments, such as Praduct cali-
bration, which may be required in accordance with the Product use and maintenance instructians.
Returns and Repairs
Prior to retuming any Product that has become defective during the applicable warranty period for a reason that ts not excluded under these War- ranty Terms, Buyer must cantact Residee customer service to obtain a return merchandise authorization (RMA) number. To obtain the RMA number. Buyer must provide: i) Product model number and serial number. ii) Proof of purchase, ui) Descnption of the defect. Buyer shall send the defective Product to Reside at its own expense, appropriately packaged to prevent damage to the Product. together with the RMA and proof of purchase, in accordance with the instructions af the Resideo customer service representative, Resideo will test the returned Product to verify that it is defective. At Resideo’s request Buyer shall provide such additional information as Resideo may reasonably require to verify the cause of the defect, including date and location of installation, Product application, manher of operation, maintenance records and failure mode. If Resideo determines that the Product is defective. Resideo will decide whether to repait or replace the Product or credit the Praduct purchase price to Buyer’s account, tf Resideo decides to replace the Product, Resideo will send the teplacement Product to Buyer at Resideo’s expense. Unless otherwise
agreed in writing, Resideo will destroy any Product that it determines to be defective, If Resideo does not find the Praduct defective. Resideo reserves the right to charge the Buyer for the reasonable casts of its investigation of the alleged defect. tf Buyer pays Resideo in advance for the costs of teturning the Product, Resideo will send the non-defective Product back ta Buyer but otherwise Resideo will destroy the Product.
Out of Warranty Repairs
At the request of Buyer, Residea will provide to Buyer a quatation far the costs to repair any Product outside of the appticable warranty periad. if Resideo considers such Product to be repairable. If Buyer accepts the quotation and sends the Product to Resideo (following the same process as for in-warranty returns), Resideo will repair the Product in accardance with the quotatian and return the repaired Product to Buyer. The repaired Product will be warranted for 90 days from the date of repair.
Miscellaneous
lf any part of these Warranty Terms is prohibited by applicable laws. the relevant part shall be null and vord, but the remainder of the Warranty Terms shall remain in full force and effect.

EC certificate of conformity 1116-CPR-161-1
**** 22
1116 Smoke Alarm
EN 14604:2005 + AC:200DoP 03062022

www.marque-nf.com

EU DECLARATION OF CONFORMITY
Hereby, Sécurité Communications SAS declares that the radio equipment type R200S-N3 is incompliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address:
CE-DoC-Security-Request@resideo.com 
Sécurité Communications SAS is registered with CITEO, Client reference 506931

Security Communications SAS
1198 Avenue Maurice Donat
06250 Mougins, France
www.resideo.com
© 2021 Resideo Technologies, Inc. All rights reserved.The Honeywell Home trademark is used under License from Honeywell International, Inc.
This product is manufactured by Resideo Technologies, Inc. and its affiliateHoneywell Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Honeywell User Manuals

Related Manuals