TANDELTA OQSxG2 Sensor Kit User Guide
- June 13, 2024
- TANDELTA
Table of Contents
TANDELTA OQSxG2 Sensor Kit User Guide
WHAT’S IN THE BOX?
Gen II Oil Quality Sensor (OQSxG2
Configuration Cable (Cable J)
CONFIGURE
-
Plug in the configuration cable and allow the update/installation of drivers.
-
Install CADS by scanning the QR code below or go to:
www.tandeltasystems.com/support/ -
Connect the sensor to the configuration cable.
-
Run CADS and configure the sensor for the correct communications and oil type.
INSTALL AND CONNECT
**ORIENTATION
**
Not recommended for engines
Sensor may not function if installed incorrectly
**IMMERSION
**
FLOW
LOCATION OPTIONS
-
OEM Port
-
Manifold/Boss
-
Tan Delta Manifold
TROUBLESHOOTING
-
Check configuration.
-
Refer to Master User Guide available at:
www.tandeltasystems.com/support -
Contact:
support@tandeltasystems.com
INTERPRETING OIL CONDITION
What does it mean?
High alert : Sensor may be in air, check sensor location and relocate if necessary.
High warning: Check sensor is configured to correct oil and correct is being used.
OK: Oil is OK for continued operation
detect oil events and increased oil wear. If either are detected, take the appropriate action to prevent equipment damage and failure
Low warning: Oil is nearing its end of life. Schedule maintenance.
Low alert: Oil is past its end of life. Change immediately
If your application is not listed, please cont. Tan Delta Support to discuss a solution.
Engine| ! Diesel engine| I Gas engine| Electrically I linsulating I (e.g.
transformer| Hydraulic| Transmission I (e.g. gearbox
---|---|---|---|---|---
1140 TDN-12.0%LF| 1140 TDN12.0%LF| 1140 TDN-12.0%LF| 1100 TDN10.0 %LF –| 1060
TDN08.0 %LF| 1100 TDN10.0 %LF
1060 TDN08.0 XLF| 1060 TDN -08.0 %LF| 1060 TDN 08.0 %LF| 1050 TDN -07.5 %LF|
1000 TDN -05.0 %LF| 1000 TDN-05.0 %LF
900 TDN0.0 %LF| 900 TDN 0.0%LF| 900 TDN0.0%LF| 900 TDN 0.0%LF| 900 TDN0.0%LF|
900 TDN 0.0 %LF
400 TDN025.0 %LF| 410 TDN 024.5%LF| 760 TDN 007.0 %LF| 760 TDN 007.0 %LF| 760
TDN 007.0 %LF| 700 TDN 010.0 %LF
300 TDN 030.0 %LF| 310 TDN 029.5 %LF| 660 TDN 012.0 %LF| 700 TDN 010.0 %LF|
660 TDN 012.0%LF| 500 TDN 020.0 %LF
SUPPORT – FAQ
f you have any issues, please read the tips below before contacting us for further support.
-
Where are the Cable J drivers?
The drivers for Cable J should install automatically. -
Does the sensor require cleaning?
No, cleaning is required once the sensor is installed. However, when using the sensor for testing offline samples (i.e. MOT Kit), then cleaning between samples is essential. -
I cannot see my oil in the database, so I have used an oil which I believe is close, but the sensor isn’t working?
The sensor will exhibit a different response for every oil. For best results, it is advised to obtain an Oil Profile which Tan Delta will add to our Oil Database. Please complete and submit an Oil Profile Request Form online at www.tandeltasystems.com/oil-availability-checker/ -
How do I update the software?
Software updates will happen automatically. You will be prompted to accept when one is available. If you are provided an installer by Tan Delta, please uninstall any previous versions of software before installing the new one. -
How do I remove the software?
Simply go into your control panel and remove the software.
You can find further information in the Master User Guide on the support page
of our
website. If you have any further questions, please contact our support team by
email:
support@tandeltasystems.com who will
answer no later than the next working day
Alternatively, refer to Master User Guide
available at:
www.tandeltasystems.com/support