Hisense ADT26UX4RBL4 Multi Conductor Instruction Manual
- June 13, 2024
- Hisense
Table of Contents
ADT26UX4RBL4 Multi Conductor
Instruction Manual
ADT26UX4RBL4 Multi Conductor
Model:
ADT26UX4RBL4
ADT35UX4RBL4
ADT52UX4RCL4
AUD71 UX4RCL4
AUD71 UX4RDH4
AUD90UX4RDH5
AUD105UX4RDH5
AUD125UX4RHH5
AUD140UX4RHH5
AUD175UX4RHH5
Thank you very much for purchasing this Air Conditioner. Please read this use and installation instructions carefully before installing and using this appliance. And keep this manual for future reference.
CAUTION Statements
Alert Symbols:
DANGER : The symbol refers to a hazard which can result in severe personal
injury or death.
WARNING: The symbol refers to a hazard or an unsafe practice which may
result in severe personal injury or death
CAUTION : The symbol refers to a hazard or an unsafe practice which may
result in personal injury, product or property damage.
NOTE : It refers to the remarks and instruction to the operation,
maintenance, and service.
- This air-conditioner should be installed properly by qualified personnel in accordance with the installation instructions provided with the unit.
- Before installation, check if the voltage of the power supply at installation site is the same as the voltage shown on the nameplate.
DANGER
- You must not carry on any transformation to this product, otherwise, it may cause water leakage, breakdown, shod-circuit, electric shock, fire, and so on.
- Piping, welding and other such works should be carried out far away from the flammable explosive material vessels, including the air-conditioner refrigerant, to guarantee the security of the site.
- To protect the air-conditioner from heavy corrosion, avoid installing the outdoor unit where sea water can splash directly onto it or in sulphurous air near a spa. Do not install the air-conditioner where excessively high heat-generating objects are placed.
WARNING
- If the supply cord is damaged, it must be replaced by the factory or its service department in case of danger.
- The place where this product is installed must have the reliable electrical grounding facility and protection. Please do not connect the grounding of this product to various kinds of air-feeding ducts, drain piping, lightning protection facility as well as other piping lines to avoid receiving an electric shock and damages caused by other factors.
- Wiring must be done by a qualified electrician. All the wiring must comply with the local electrical codes.
- Consider the capacity of the electric current of your electrical meter and socket before installation.
- The power wire where this product is installed is supposed to have the independent leakage protective device and the electric current over-load protection device which are provided for this product.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- Means for disconnection, which can provide full disconnection in all poles, must be incorporated in the fixed wiring in accordance with the wiring rules .
- Read this manual carefully before using this air-conditioner. If you still have any difficulties or problems, consult your dealer for help.
- The air-conditioner is designed to provide you with comfortable room conditions. Use this unit only for its intended purpose as described in this instruction manual.
WARNING
- Never use gasoline or other inflammable gas near the air-conditioner, which is very dangerous.
- When the air conditioner operation is abnormal, such as burnt smell, deformation, fire, smoke, and so on, it is forbidden to continue using the air conditioner, the main power switch of the air conditioner must be cut off immediately and the agent must be contacted.
CAUTION
-
Do not turn the air-conditioner on and off from the main power switch. Use the ON/OFF operation button.
-
Do not stick anything into the air inlet and air outlet of both the indoor and outdoor units. This is dangerous because the fan is rotating at a high speed.
-
Do not cool or heat the room too much if babies or invalids are present.
Do not turn the air-conditioner on and off from the main power switch. Use the ON/OFF operation button. -
Details of type and rating of circuit breakers / ELB is detailed in outdoor instruction manual.
-
The method of connection of the appliance to the electrical supply and interconnection of separate components is detailed in below part.
-
The wiring diagram with a clear indication of the connections and wiring to external control devices and supply cord is detailed in below part. The cord of the H0?RN-F type or the electrically equivalent type must be used for power connection and interconnection between outdoor unit and indoor unit. The size of the cord is detailed in below part.
-
The information of dimensions of the space necessary for correct installation of the appliance including the minimum permissible distances to adjacent structures is detailed in below part.
-
The range of external static pressures for ducted appliances is detailed in below part.
NOTE:
Storage condition: Temperature -25–60°C Humidity 30%-80%
Safety Precautions
Precautions for using R32 refrigerant
The basic installation work procedures are the same as the conventional
refrigerant (R22 or R41 OA).
However, pay attention to the following points:
WARNING
-
Transport of equipment containing flammable refrigerants.
Attention is drawn to the fact that additional transportation regulations may exist with respect to equipment containing flammable gas. The maximum number of pieces of equipment or the configuration of the equipment, permitted to be transported together will be determined by the applicable transport regulations. -
Marking of equipment using signs
Signs for similar appliances (containing flammable refrigerants) used in a work area generally are addressed by local regulations and give the minimum requirements for the provision of safety and/or health signs for a work location. All required signs are to be maintained and employers should ensure that employees receive suitable and sufficient instruction and training on the meaning of appropriate safety signs and the actions that need to be taken in connection with these signs. The effectiveness of signs should not be diminished by too many signs being placed together. Any pictograms used should be as simple as possible and contain only essential details. -
Disposal of equipment using flammable refrigerants
Compliance with national regulations -
Storage of equipment/appliances
The storage of equipment should be in accordance with the manufacturer’s instructions. -
Storage of packed (unsold) equipment
• Storage package protection should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge.
• The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations. -
Information on servicing
6-1 Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions should be complied with prior to conducting work on the system.
6-2 Work procedure
Work shall be undertaken under a controlled procedure so as to minimise the risk of flammable gas or vapours being present while the work is being performed.
6-3 General work area
• All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided.
• The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.
6-4 Checking for presence of refrigerant
• The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres.
• Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe.
6-5 Presence of fire extinguisher
• If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand.
• Have a dry powder or CO, fire extinguisher adjacent to the charging area.
6-6 No ignition sources
• No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion.
• All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding space.
• Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. “No Smoking” signs shall be displayed.
6-7 Ventilated area
• Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work.
• A degree of ventilation shall continue during the period that the work is carried out.
• The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.
6-8 Checks to the refrigeration equipment
• Where electrical components are being changed, they shall be fit for the purpose and to the correct specification.
• At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance.
• The following checks shall be applied to installations using flammable refrigerants:
The charge size is in accordance with the room size within which the refrigerant containing parts are installed;
– The ventilation machinery and outlets are operating adequately and are not obstructed;
– If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant; Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected;
-Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded.
6-9 Checks to electrical devices
• Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures.
• If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with.
• If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used.
• This shall be reported to the owner of the equipment so all parties are advised.
• Initial safety checks shall include:
• That capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking;
• That there no live electrical components and wiring are exposed while charging, recovering or purging the system;
• That there is continuity of earth bonding. -
Repairs to sealed components
• During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc.
• If it is absolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
• Particular attention shall be paid to the following to ensure that by working on electrical components, the casing is not altered in such a way that the level of protection is affected.
• This shall include damage to cables, excessive number of connections, terminals not made to original specification, damage to seals, incorrect fitting of glands, etc.
• Ensure that apparatus is mounted securely.
• Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of flammable atmospheres.
• Replacement parts shall be in accordance with the manufacturer’s specifications.
NOTE: The use of silicon sealants may inhibit the effectiveness of some types of leak detection equipment. Intrinsically safe components do not have to be isolated prior to working on them. -
Repair to intrinsically safe components
• Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use.
• Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere.
The test apparatus shall be at the correct rating.
• Replace components only with parts specified by the manufacturer.
• Other parts may result in the ignition of refrigerant in the atmosphere from a leak. -
Cabling
• Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects.
• The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans. -
Detection of flammable refrigerants
• Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks.
• A halide torch (or any other detector using a naked flame) shall not be used. -
Leak detection methods
The following leak detection methods are deemed acceptable for systems containing flammable refrigerants:
• Electronic leak detectors shall be used to detect flammable refrigerants, but the sensitivity may not be adequate, or may need re-calibration. (Detection equipment shall be calibrated in a refrigerant-free area.)
• Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used.
• Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25 % maximum) is confirmed.
• Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe-work.
• If a leak is suspected, all naked flames shall be removed/ extinguished.
• If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system, or isolated (by means of shut off valves) in a part of the system remote from the leak.
• Oxygen free nitrogen (OFN) shall then be purged through the system both before and during the brazing process. -
Removal and evacuation
• When breaking into the refrigerant circuit to make repairs – or for any other purpose -conventional procedures shall be used.
• However, it is important that best practice is followed since flammability is a consideration.
• The following procedure shall be adhered to:
Remove refrigerant;
Purge the circuit with inert gas;
Evacuate;
Purge again with inert gas;
Open the circuit by cutting or brazing.
• The refrigerant charge shall be recovered into the correct recovery cylinders.
• The system shall be “flushed” with OFN to render the unit safe.
• This process may need to be repeated several times.
• Compressed air or oxygen shall not be used for this task.
• Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum.
• This process shall be repeated until no refrigerant is within the system. When the final OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place.
• This operation is absolutely vital if brazing operations on the pipe-work are to take place.
• Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available. -
Charging procedures
• In addition to conventional charging procedures, the following requirements shall be followed:
– Ensure that contamination of different refrigerants does not occur when using charging equipment.
– Hoses or lines shall be as short as possible to minimise the amount of refrigerant contained in them.
– Cylinders shall be kept upright.
– Ensure that the refrigeration system is earthed prior to charging the system with refrigerant.
– Label the system when charging is complete (if not already).
– Extreme care shall be taken not to overfill the refrigeration system.
– Prior to recharging the system it shall be pressure tested with OFN.
• The system shall be leak tested on completion of charging but prior to commissioning.
• A follow up leak test shall be carried out prior to leaving the site. -
Decommissioning
Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail.
It is recommended good practice that all refrigerants are recovered safely.
Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant. It is essential that electrical power is available before the task is commenced.
a) Become familiar with the equipment and its operation.
b) Isolate system electrically.
c) Before attempting the procedure ensure that:
• Mechanical handling equipment is available, if required, for handling refrigerant cylinders;
• All personal protective equipment is available and being used correctly;
• The recovery process is supervised at all times by a competent person;
• Recovery equipment and cylinders conform to the appropriate standards.
d) Pump down refrigerant system, if possible.
e) If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system.
f) Make sure that cylinder is situated on the scales before recovery takes place.
g) Start the recovery machine and operate in accordance with manufacturer’s instructions.
h) Do not overfill cylinders. (No more than 80 % volume liquid charge).
i) Do not exceed the maximum working pressure of the cylinder, even temporarily.
j) When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the equipment are removed from site promptly and all isolation valves on the equipment are closed off.
k) Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked. -
Labelling
Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant.
The label shall be dated and signed.
Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant. -
Recovery
• When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely.
• When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed.
• Ensure that the correct number of cylinders for holding the total system charge is available.
• All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant (i.e. special cylinders for the recovery of refrigerant).
• Cylinders shall be complete with pressure relief valve and associated shut- off valves in good working order.
• Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs.
• The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants.
• In addition, a set of calibrated weighing scales shall be available and in good working order.
• Hoses shall be complete with leak-free disconnect couplings and in good condition.
• Before using the recovery machine, check that it is in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release.
• Consult manufacturer if in doubt.
• The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant Waste Transfer Note arranged.
• Do not mix refrigerants in recovery units and especially not in cylinders.
• If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant.
• The evacuation process shall be carried out prior to returning the compressor to the suppliers.
• Only electric heating to the compressor body shall be employed to accelerate this process.
• When oil is drained from a system, it shall be carried out safely.
• Appliance shall be installed, operated and stored in a room with a floor area larger than X (X see below).
• The installation of pipe-work shall be kept to a a room with a floor area larger than X (X see below).
• The pipe-work shall be compliance with national gas regulations.
• When moving or relocating the air conditioner, consult experienced service technicians for disconnection and reinstallation of the unit.
• Do not place any other electrical products or household belongings under indoor unit or outdoor unit.
• Condensation dripping from the unit might get them wet, and may cause damage or malfunction of your property .
• Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
• The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
• Do not pierce or burn.
• Be aware that refrigerants may not contain an odor.
• To keep ventilation openings clear of obstruction.
• The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
• The appliance shall be stored in a room without continuously operating open flames (for example an operating gas appliance) and ignition sources (for example an operating electric heater).
• Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry recognized assessment specification.
• Servicing shall only be performed as recommended by the equipment manufacturer.
• Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
• The appliance shall be installed and stored so as to prevent mechanical damage from occurring.
• Mechanical connectors used indoors shall comply with ISO 14903. When mechanical connectors are reused indoors, sealing parts shall be renewed. When flared joints are reused indoors, the flare part shall be re-fabricated.
• The installation of pipe-work shall be kept to a minimum.
• Mechanical connections shall be accessible for maintenance purposes.
Required minimum room area X (m²)
Series | Model (x100W) | Installation height (m) |
---|---|---|
0.6 | 1.0 | 2. |
Multi-split | 26/35/52/71 | 111 |
Unitary | 26/35 | No limit |
52 | 14 | 5 |
71 | 38. | 14. |
90 | 63. | 23. |
105 | 91. | 33. |
125 | 120. | 43. |
142 | 156. | 56. |
175 | 185. | 67. |
Explanation of symbols displayed on the indoor unit or outdoor unit.
| WARNING| This symbol shows that this appliance uses a flammable
refrigerant. If the refrigerant is leaked and exposed to an external ignition
source, there is a risk of fire.
---|---|---
| CAUTION| This symbol shows that the operation manual should be read
carefully.
| CAUTION| This symbol shows that a service personnel should be handling
this equipment with reference to the installation manual.
| CAUTION| This symbol shows that information is available such as the
operating manual or installation manual.
Composition of the Air-conditioner
Indoor unit
- Air inlet
- Electric box
- Refrigerant pipe (Liquid)
- Refrigerant pipe (Gas)
- Drain pipe (Connect with pump)
- Drain pipe
- Air outlet
Remote controller( optional)
You can control the air-conditioner with the wire remote controller or
wireless remote controller.
It is used for controlling power ON/OFF,setting the running mode, temperature,
fan speed and other functions.
There are different types of remote controllers that can be used.
Operation instructions will be further specified in remote controller’s
manual.
Please read it carefully before using this appliance and keep it for future
reference.
Note: The figures are based on the external views of the standard model. Consequently, the shape may differ for the air conditioner model you have selected.
Before Operation
Special remarks
-
3 minutes protection after compressor stop
To protect compressor, it will be continue to be off for at least 3 minutes once it has stopped. -
5 minutes protection
Compressor must run for at least 5 minutes once operational. In the 5 minutes, compressor will not stop even the room temperature reaches the setting temperature point unless you use remote controller to turn off the unit (all indoor unit can be turned off by user). -
Cooling operation
The fan of the indoor unit will never stop running in cooling operation. It continues to operate even if the compressor stops working. -
Heating operation
Heating capacity depends on external factors like outdoor unit temperature. Heating capacity might decrease if outdoor ambient temperature is too low. -
Anti-freezing function during cooling
When the temperature of the air from the indoor outlet is too low, the unit will run for some time under the fan mode, to avoid frost or ice forming on the indoor heat exchanger. -
Cold air prevention
In several minutes after the heating mode is started, the fan of the indoor unit will not run until the heat exchanger of the indoor unit reaches a certain temperature to prevent cold draft. -
Defrosting
When the outdoor temperature is too low, frost or ice may form on the outdoor heat exchanger, reducing heating performance. When this happens, a defrosting system of the air conditioner will operate. At the same time the fan in the indoor unit stops (or runs at a very low speed in some cases), to prevent cold draft. After defrosting is over, the heating operation and fan speed restart. -
Blow out the survival heating air
When stopping the air conditioner in normal operation, the fan motor will run with low speed for a while to blow out the residual heating air. -
Auto re-start from of Power Break
When the power supply is recovered after power break, all presets are still effective and the air-conditioner will run according to the previous setting.
Troubleshooting
CAUTION
If the trouble persists even after checking the following, contact your dealer
and inform them of the items. according to the original setting.
-
If Trouble Still Remains …
(1) Unit Model Name
(2) Content of Trouble -
No Operation
Check whether the SET TEMP is set at the correct temperature. -
Not Cooling or Heating properly
• Check for obstruction of air flow in indoor and outdoor units.
• Check if too many heating sources are located in the room.
• Check if the air filter is clogged with dust.
• Check if the doors or windows are open.
• Check if the temperature condition is not within the operation range. -
This is Not Abnormal
• Odour from indoor unit
Unpleasant Odour diffuses from indoor unit after a long period of time. Clean the air filter and panels or allow a good ventilation.
• Sound from Deforming Parts
During system start or stop, a sound might be heard. However, this is due to thermal deformation of plastic parts. It is not abnormal.
• Steam from Outdoor Heat Exchanger
During defrosting operation, ice on the outdoor heat exchanger melts resulting in steam.
• Dew on Air Panel
When the cooling operation continues for a long period of time under high humidity conditions, dew may form on the air panel, please set the appliance at high fan speed and adjust louvers to the max. angle.
• Refrigerant Flow Sound
While the system is being started or stopped, sound from the refrigerant flow may be heard. -
Mode Interfere (Only for multi-split)
For the reason that all indoor units use one outdoor unit, outdoor unit can only run with same
mode (cooling or heating), so, when the mode you set is different from the mode that outdoor is running with,
mode interfere occurs. Following shows the mode interfere scene.Outdoor unit always run with the mode of first indoor unit that turned on. when the setting mode of following indoor unit is interfered with it, 3 beeps would be heard, and the indoor unit interfered with the normal running units would turn off automatically.
Installation and Maintenance
1. Safety Notice
WARNING
-
Installation should be performed by a qualified personnel. (Improper installation may cause water leakage, electrical shock or fire.)
-
Install the unit according to the instructions given in this manual. (Incomplete installation may cause water leakage, electrical shock or fire).
-
Be sure to use the supplied or specified installation parts. (Use of other parts may cause the unit to get loosened, water leakage, electrical shock or fire).
-
Install the air conditioner on a solid base that can support the unit weight. (An inadequate base or incomplete installation may cause injury if the unit falls off the base).
-
Electrical work should be carried out in accordance with the installation manual and the local national electrical wiring rules or code of practice. (Insufficient capacity or incomplete electrical work may cause electrical shock or fire).
-
Be sure to use a dedicated power circuit. (Never use a power supply shared by another appliance).
-
For wiring, use a cable long enough to cover the entire distance. Do not use an extension cord.
-
Do not put other loads on the power supply, use a dedicated power circuit.
-
Use the specified types of wires for electrical connections between the indoor and outdoor units. (Firmly clamp the interconnecting wires so their terminals receive no external stresses).
-
Incomplete connections or clamping may cause terminal overheating or fire.
-
After connecting all the wires be sure to fix the cables so that they do not put undue force on the electrical covers or panels. (Install covers over the wires, incomplete cover installation may cause terminal overheating, electrical shock or fire).
-
When installing or relocating the system, be sure to keep the refrigerant circuit free from air (Air in the refrigerant circuit may causes an abnormal pressure rise or rupture, resulting in injury).
-
If any refrigerant has leaked out during the installation work, ventilate the room.
-
After all installation is completed, check to make sure that no refrigerant is leaking out. (The refrigerant produces a toxic gas if exposed to flames).
-
When carrying out piping connection, take care not to let air substances other than the specified refrigerant get into refrigeration cycle. (Otherwise, it will cause lower performance, abnormal high pressure in the refrigeration cycle, explosion and injury).
-
Make sure that the installation is properly grounded. Do not ground the unit to a utility pipe, lightning arrester, or telephone grounding. Incomplete grounding may cause electrical shock. (A high surge current from lightning or other sources may cause damage to the air conditioner).
-
An earth leakage circuit breaker may be required depending on the site condition to prevent electrical shock.
-
Disconnect the power supply before wiring, piping, or checking the unit.
-
When moving the indoor unit and outdoor unit, please be careful, do not make the outdoor unit incline over 45 degree. Pay attention to the sharp edges of the air conditioner to avoid any injury.
-
During remote controller installation, ensure that the length of the wire between the indoor unit and remote controller is within 40 meters.
CAUTION -
Do not install the air conditioner in a place where there is danger of exposure to inflammable gas leakage. (If the gas leaks and builds up around the unit, it may catch fire).
-
Establish drain piping according to the instructions in this manual. (Inadequate piping may cause flooding).
-
Tighten the flare nut according to the specifications with a torque wrench. (If the flare nut is tightened beyond specified torque, the flare nut may crack after a long time and cause refrigerant leakage).
The Tools and Instruments for Installation
Number | Tool | Number | Tool |
---|---|---|---|
1 | Standard screwdriver | 8 | Knife or wire stripper |
2 | Vacuum pump | 9 | Leveler |
3 | Charge hose | 10 | Hammer |
4 | Pipe bender | 11 | Churn drill |
5 | Adjustable wrench | 12 | Tube expander |
6 | Pipe cutter | 13 | Inner hexagon spanner |
7 | Cross head screw-driver | 14 | Measuring tape |
The Installation of the Indoor Unit
CAUTION
During installation, do not damage the insulation material on the surface of
the indoor unit.
3.1 The Initial Check
CAUTION
· When moving the unit after unpacking, make sure to lift it by holding its
lifting lugs. Do not exert any pressure on other parts, especially the
refrigerant piping, drain piping and flange parts.
• Wear protective gears when installing the unit.
- Optimum air distribution is ensured.
- The air passage is not blocked.
- Condensate can drain properly.
- The ceiling is strong enough to bear the weight of the indoor unit.
- A false ceiling does not seem to be at an incline.
- Sufficient clearance for maintenance and servicing is ensured.(See Fig.3.1.1,Fig3.1.2 )
- Piping between the indoor and outdoor units is within the allowable limits.(refer to the installation of the outdoor unit )
- The indoor unit, outdoor unit, power supply wiring and transmission wiring must be kept at least 1 meter away from televisions and radio, this prevents image interference and noise in electrical appliances. (Noise may be generated depending on the conditions under which the electric wave is generated, even if a one-meter allowance is maintained.)
- Do not install the indoor unit in a machinery shop or kitchen where vapor from oil or its mist flows to the indoor unit. The oil will deposit on the heat exchanger, thereby reducing the performance of the indoor unit, and may deform and in the worst case, break the plastic parts of the indoor unit.
- Use suspension bolts to install the unit, check whether or not the ceiling is strong enough to support the weight of the unit. If there is a risk that the ceiling is not strong enough, reinforce the ceiling before installing the unit.
For bottom intake(Model125~175), replace the chamber lid and the intake-side flange in the procedure listed in below figures.
(1) Remove the intake-side flange, then remove the chamber lid. Refer to Fig. 3.1.3 for the directions.
(2) Reattach the removed chamber lid in the orientation shown in Fig. 3.1 .4, reattach the removed intake-side flange in the orientation as shown in Fig. 3.1.4.
3.2 Installation
3.2.1 Suspension bolts
(1) Consider the pipe direction, wiring and maintenance carefully, and choose
the proper direction and location for installation.
(2) Install the suspension bolts as shown in Fig. 3.2.1 below .
3.2.2 The position of the suspension bolts and the pipes
(1) Mark the positions of the suspension bolts, the positions of the
refrigerant pipes and the drain pipes.
(2) The dimension are shown below. (Unit:mm)
Model (Cooling capacity) | a | b | c | d |
---|---|---|---|---|
26/35 | 961 | 910 | 375 | 447 |
52/71 | 1231 | 1180 | 375 | 447 |
90/105 | 1177 | 1140 | 666 | 720 |
125/140/175 | 1334 | 1300 | 756 | 800 |
Fig. 3.3 Suspension bolts
3.2.3 Install the indoor unit.
The installation of the indoor unit is shown in Fig. 3.4.
(1) How to fix the suspension bolts and the nuts As shown in the figures 3.5, the nuts are fixed four bolts.
(2) Install the indoor unit
• As shown in the following figure, place the left hanger bracket on the nuts
and washers of the suspension bolts.
• Make sure that the left hanger bracket has been fixed on the nuts and
washers securely, install the right hanger bracket suspension hook on the nuts
and washers.
(When installing the indoor unit, you can slightly remove the suspension
bolts.) 3.2.4 Adjusting of the unit level
- Check to ensure that the foundation is flat, taking into account the maximum foundation gradient.
- The unit should be installed that the drainage side is slightly (Omm-5mm) lower than other sides for adequate drainage.
- After the adjustment, tighten the nuts and swear the thread locker on the suspension to prevent the nuts from loosening.
CAUTION
- During the installation, please cover the unit with the plastic cloth to keep it clean.
- Make sure that the unit is installed level by using a level or a plastic tube filled with water in instead of a level, adjust the top surface of the unit to the surface of the water at both ends of the plastic tube and adjust the unit horizontally. (one thing to watch out for in particular is if it is installed so that the slope is not in the direction of the drain piping, as this might cause leaking.)
3.2.5 Installing the duct
CAUTION
- Make sure the external static pressure of the unit is within the range.
- Connect the duct and intake-side flange.
- Connect the duct and outlet-side flange.
- The connection of indoor unit and air duct must be well sealed and kept warm with insulation material.
Refrigerant Pipe
DANGER
Use the refrigerant according to outdoor nameplate.
When carrying on the leakage check and test, do not mix in the oxygen, the
acetylene and flammable and the virulent gas, for these gases are quite
dangerous, and may possibly cause explosion. It is suggested that the nitrogen
be used to perform these experiments.
4.1 The Pipe Material
- Prepare the copper pipe on the spot.
- Choose dustless, non-humid, clean copper pipe. Before installing the pipe, use nitrogen or dry air to blow away the tube dust and impurity.
- Choose the copper pipe according to Fig. 4.2.
4.2 The Connection of the Pipe
(1) The connection positions of the pipe are shown in Fig. 4.1 and Fig. 4.2.
Model (100W) | Gas Pipe | Liquid Pipe |
---|---|---|
26~35 | 0 9.52 | 0 6.35 |
52 | 4 12.7 | 6.35 |
71~175 | 15.88 | 9.52 |
Fig. 4.2 The pipe diameter
(2)As shown in Fig. 4.3, screw up the nuts with 2 spanners.
Tube size | Torque (N.m) |
---|---|
6.35mm | 20 |
9.52mm | 40 |
12.7mm | 60 |
15.88mm | 80 |
(3) After finishing connecting the refrigerant pipes, keep it warm with the insulation material.
CAUTION
- The pipe go through the hole with the seal.
- Do not put the pipes on the floor directly.
Drain piping
- Install the drain piping
- Make sure the drain works properly .
- Prepare polyvinyl chloride pipe with a 32mm outer diameter.
- The diameter of drain pipe connection hole should be same as that of the drain pipe.
- Keep the drain pipe short and sloping down wards at a gradient of at least 1/100 to prevent air pockets from forming.
NOTE
When the relative humidity of inlet or ambient air exceeds 80%,apply an
(field-supplied) auxiliary drain pan beneath the indoor unit as shown below.
[ CAUTION]
Water accumulating in the drain piping can cause the drain to clog.
-
To keep the drain tube from sagging, space hanging wires every 1 to 1.5 m.
-
Use the drain hose and the clamp. Insert the drain hose fully into the drain socket and firmly tighten the drain hose and warm-keeping material with the clamp.
-
The two areas below should be insulated because condensation may happen there causing water leakage.
-
Drain piping passing indoors
-
Drain sockets.
-
Referring the figure below, insulate the drain socket and drain hose using the included large sealing pad.
[ CAUTION]
Drain piping connections -
Do not connect the drain pipes directly to sewage pipes to avoid ammonia Odour. The ammonia in the sewage might enter the indoor unit through the drain pipes and corrode the heat exchanger.
-
Do not twist or bend the drain hose, doing so applies excessive force applied on it and may also cause leakage.
-
After piping work is finished, check if drainage flows smoothly.
-
Gradually pour approximately 1000 cc of water from the outlet hole into the drain pan to check drainage flow.
-
Check the drainage as shown below:
Electrical Wiring
6.1 General Check
**CATION**
- When clamping the wiring, use the included clamping material as shown in the Fig.6.1 to prevent external pressure being exerted on the wiring connections and clamp firmly.
- While performing wiring work, make sure the wiring is proper and does not cause the control box lid to stick up, then close the cover firmly. When attaching the control lid, make sure you do not pinch any wires.
- Outside the indoor unit and outdoor unit, separate the weak wiring (remote controller and transmission wiring) and strong wiring (ground and power supply wiring) at least 50 mm so that they do not pass through the same place together. Proximity may cause electrical interference malfunction and breakage.
WARNING
If the fuses burn up, please call the authorized service dealer. Please do not
replace it by yourself, as it may result in accident or electric shock.
- As shown in Fig. 6.1, remove the screws on the control box.
- Connect the power cord and ground wire to the main terminal.
- Connect the remote control wire to the subsidiary terminal box.
- Connect the power supply of the indoor and outdoor units to the main terminal.
- Tie the wire in the control box with the clamp tightly.
- After completing the wiring, seal the wiring hole with the sealing material (with the lid) to prevent the condensation and insects entering the control box.
Electrical Wiring Diagram
6.2 Change of Static Pressure
The static pressure can be freely adjusted by using specific wire remote
controller .
Model (Capacity x 100W) | The range of static pressure | Function code set |
---|---|---|
26/35/52 | 0-50Pa | 0-50, more than 50 is 50 Pa, [default: 0 (35Pa)] |
71(LSP) | 0-40Pa | 0-40, more than 40 is 40 Pa, [default: 0 (35Pa)] |
71(MSP)-175 | 0-150Pa | 1-150, more than 150 is 150 Pa, [default: 0 (100Pa)] |
Static pressure setting:
- Hold down both”MODE”button and”ADD.FUNC.”button for 3 seconds, symbol and parameter code blinking at the same time.
- Press” “button to adjust parameter number until display “17”, and press “ENTER “button to entering system parameter adaption state, symbol stop blinking.
- Select desired parameter code 10 by pressing “ ” button , and press “ENTER” button to confirm.
- Select desired function code to rewrite the parameter values by pressing “ “button , and press “ENTER” button to confirm.
- Press “ON/OFF”button or “CANCEL “button to quit.
If you still have any trouble, please contact local technical service center of our company for further information.
6.3 Electrical Installation
WARNING
- Use an ELB (Electric Leakage Breaker). If not used, it will cause an electric shock or a fire.
- Do not operate the system until all the check points have been cleared.
(A) Check to ensure that the insulation resistance is more than 2MO, by measuring the resistance between ground and the terminal of the electrical parts. If not, do not operate the system until the electrical leakage is found and repaired.
(B) Check to ensure that the stop valves of the outdoor unit are fully opened and then start the system.
Model Capacity(100W) | Transmitting Cable Size |
---|
EN60335-1
26~175| 4X1. 5mm
Max. Running Current(A): REFER TO NAMEPLATE
NOTES:
-
Follow local codes and regulations when selecting field wires.
-
The wire sizes marked in the table are selected at the maximus current of the unit according to the
European Standard ,En60 335-1.Use the wires which are not lighter than the ordinary polychloroprene sheathed flexible cord (code designation HO?RN-F) .When connecting the terminal block using flexible cord, make sure to use the round crimp-style terminal for connection to the power supply terminal block.
Place the round crimp-style terminals on the wires up to the covered part and secure in place.
When connecting the terminal block using a single core wire, be sure to perform curing. -
When transmitting cable length is more than 15 meters, a larger wire size should be selected.
-
Use a shielded cable for the transmitting circuit and connect it to ground.
-
In the case that power cables are connected in series, add each unit maximum current and select wires below.
Selection According to EN60335-1Current i(A)| Wire Size(mm)
---|---
i<6| 0. 75
6<i<10| 1
10<i=16| 1. 5
16<i<25| 2.5
25<1<32| 4
32<i=40| 6
40<i<63| 10
63<i| k
*In the case that current exceeds 63A, do not connect cables in series.
Trial Run
Please perform trial run according to outdoor unit installation manual.
Correct Disposal of this product
This marking indicates that this product should not be disposed with other
household wastes throughout the EU. To prevent possible harm to the
environment or human health from uncontrolled waste disposal, recycle it
responsibly to promote the sustainable reuse of material resources. To return
your used device, please use the return and collection systems or contact the
retailer where the product was purchased. They can take this product for
environmental safe recycling.