MEAN WELL RD-65A Serie Dual Output Switching Power Supply Owner’s Manual

June 13, 2024
MEAN WELL

MEAN WELL RD-65A Serie Dual Output Switching Power Supply

MEAN WELL RD-65A Serie Dual Output Switching Power
Supply

Features

  • Universal AC input/ Full range
  • Protections: Short circuit/ Overload/ Over voltage
  • Cooling by free air convection
  • LED indicator for power on
  • 100% full load burn-in test
  • All using 105°C long life electrolytic capacitors
  • Withstand 300VAC surge input for 5 second
  • High operating temperature up to 70″C
  • Withstand 5G vibration test
  • High efficiency, long life and high reliability
  • 3 years warranty

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

SPECIFICATION

MODEL RD-65A RD-65B
OUTPUT OUTPUT NUMBER CH1
DC VOLTAGE 5V 12V
RATED CURRENT 6A 3A
CURRENT RANGE Note.6 0-8A 0-4A
RATED POWER Note.6 66W 68W
RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p

150mVp-p
VOLTAGE ADJ. RANGE| CH1: 4.75 – 5.5V| CH1: 4.75- 5.5V
VOLTAGE TOLERANCE Note.3| ±2.0%| ±6.0%| ± 2.0%| +4,-8%
LINE REGULATION Note.4| ±0.5%| ±1.5%| ±0.5%| ±2.0%
LOAD REGULATION Note.5| ±0.5%| ±3.0%| ±0.5%| ±6.0%
SETUP, RISE TIME| 500ms, 20ms/230VAC         1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)| 60ms/230VAC         14ms/115VAC at full load
INPUT| VOLTAGE RANGE| 88- 264VAC        125- 373VDC (Withstand 300VAC surge for 5sec. Without damage)
FREQUENCY RANGE| 47- 63Hz
EFFICIENCY(Typ.)| 78%| 77%
AC CURRENT (Typ.)| 2A/115VAC         1.2A/230VAC
INRUSH CURRENT (Typ.)| COLD START 50A/230VAC
LEAKAGE CURRENT| <2mA/ 240VAC
PROTECTION| OVERLOAD| 110 – 150% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE| CH1: 5.75- 6.75V
Protection type: Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT| WORKING TEMP.| -25 – +70°C (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 – 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40- +85°C, 10-95% RH
TEMP. COEFFICIENT| ± 0.03%/°C (0 – 50°C )on +5V output
VIBRATION| 10-500Hz, 5G 10min./1cycle, period for60min. each along X, Y, Z axes
SAFETY & EMC (Note 7)| SAFETY STANDARDS| UL62368-1, TUV BS EN/EN62368-1 , EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-0/P, I/P-FG, O/P-FG:100M Ohms/ 500VDC / 25″C/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020
OTHERS| MTBF| 2940.2K hrs min.    Telcordia SR-332 (Bellcore); 541.0K hrs min.     MIL-HDBK-217F (25’C)
DIMENSION| 129’98’38mm (L’W’H)
PACKING| 0.44Kg; 30pcs/14.2Kg/0.72CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance: includes set up tolerance, line regulation and load regulation, when multi-channel output, it is recommended that CH1 load> 10%.
  4. Line regulation is measured from low line to high line at rated load.
  5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
  6. Each output can work within current range. But total output power can’t exceed rated output power.
  7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm’360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
  8. The ambient temperature derating of 3SC/1000m with fanless models and of 5″C/1000m with fan models for operating altitude higher than 2000m(6500ft) Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

Mechanical Specification

Terminal Pin No. Assignment

Pin No. Assignment Pin No. Assignment
1 AC/L 4,6 DC OUTPUT COM
2 AC/N 5 DC OUTPUT +V2
3 FG ½ 7 DC OUTPUT +V1

Block Diagram

Block Diagram

Derating Curve

Derating Curve

Output Derating VS Input Voltage

Output Derating VS Input Voltage

Customer Support

Symbols

QR Code

Arrow.com

MEAN WELL Logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals