MEAN WELL RS-100-3.3 100W Single Output Switching Power Supply Owner’s Manual

June 13, 2024
MEAN WELL

MEAN WELL RS-100-3.3 100W Single Output Switching Power Supply

MEAN WELL RS-100-3.3 100W Single Output Switching Power
Supply

Features

  • Universal AC input/ Full range
  • Protections: Short circuit/ Overload/ Over voltage
  • Cooling by free air convection
  • LED indicator for power on
  • 100% full load burn-in test
  • All using 105″C long life electrolytic capacitors
  • Withstand 300VAC surge input for 5 second
  • High operating temperature up to 70°C
  • Withstand 5G vibration test
  • High efficiency, long life and high reliability
  • 3 years warranty

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

SPECIFICATION

MODEL| RS-100-3.3| RS-100-5| RS-100-12| RS-100-15| RS-100-24| RS-100-48
---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 3.3V| 5V| 12V| 15V| 24V| 48V
RATED CURRENT| 20A| 16A| 8.5A| 7A| 4.5A| 2.3A
CURRENT RANGE| 0 ~ 20A| 0 – 16A| 0 – 8.5A| 0 – 7A| 0 – 4.5A| 0- 2.3A
RATED POWER| 66W| BOW| 102W| 105W| 108W| 110.4W
RIPPLE & NOISE (max.) Note.2| 80mVp-p| 80mVp-p| 120mVp-p| 120mVp-p| 120mVp-p| 200mVp-p
VOLTAGE ADJ. RANGE| 3.2V ~ 3.5V| 4.75 ~ 5.5V| 11.4~ 13.2V| 14.25 – 16.5V| 22.8 – 26.4V| 45.6 – 52.8V
VOLTAGE TOLERANCE Note.3| ±3.0%| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION Note.4| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION Note.5| ±2.0%| ±1.0%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 500ms , 20ms/230VAC  1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)| 95ms/230VAC  17ms/115VAC at full load
INPUT| VOLTAGE RANGE| 88 – 264VAC  125- 373VDC (Withstand 300VAC surge for 5sec. Without damage)
FREQUENCY RANGE| 47 – 63Hz
EFFICIENCY (Typ,)| 74%| 77%| 81%| 82%| 84%| 84%
AC CURRENT (Typ.)| 2.5A/115VAC         1.5A/230VAC
INRUSH CURRENT (Typ,)| COLD START 40A/230VAC
LEAKAGE CURRENT| <2mA/ 240VAC
PROTECTION| OVERLOAD| 110 – 150% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE| 3.8 ~ 4.45V| 5.75 – 6.75V| 13.8 – 16.2V| 17.25 – 20.25V| 27.6 – 32.4V| 55.2 – 64.8V
Protection type: Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT| WORKING TEMP.| -25- +70°C (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 – 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85″C, 10-95% RH
TEMP. COEFFICIENT| ±0 03%/C (0 – 50”C)
VIBRATION| 10 – 500Hz, 5G 1Omin./1cycle, period for 60min. each along X , Y, Z axes
SAFETY & EMC (Note 6)| SAFETY STANDARDS| UL62368-1, TUV BS EN/EN62368-1 , AS/NZS 62368.1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| 1/P-0/P, 1/P-FG, 0/P-FG:1 QOM Ohms/ 500VDC / 25″Ci 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2) , heavy industry level, EAC TP TC 020
OTHERS| MTBF| 3196.6K hrs min.    Telcordia SR-332 (Bellcore); 526.7K hrs min.      MIL-HDBK-217F (25°C)
DIMENSION| 159’97’38mm (L’W’H)
PACKING| 0.6Kg; 24pcs/15.4Kg/0.83CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25″C of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. Line regulation is measured from low line to high line at rated load.
  5. Load regulation is measured from 0% to 100% rated load.
  6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
  7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
  8. The ambient temperature derating of 3.5°C /1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft) Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

Mechanical Specification

Terminal Pin No. Assignment

Pin No. Assignment Pin No. Assignment
1 AC/L 4,5 DCOUTPUT-V
2 AC/N 6,7 DCOUTPUT+V
3 FG-½

Block Diagram

Block Diagram

Derating Curve

Derating Curve

Static Characteristics

Static Characteristics

Customer Support

Symbols

QR Code

Arrow.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals