OXBOX JAYHAK96001A Conversion Kit for Two-Stage Gas Valve Installation Guide
- June 13, 2024
- Oxbox
Table of Contents
- OXBOX JAYHAK96001A Conversion Kit for Two-Stage Gas Valve
- Product Usage Instructions
- APPLICATION
- TO CONVERT FROM NATURAL
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
- 47 Drill Size Burner Orifice Kit
- 48 Drill Size Burner Orifice Kit
- 56 Drill Size Burner Orifice Kit
- 57 Drill Size Burner Orifice Kit
OXBOX JAYHAK96001A Conversion Kit for Two-Stage Gas Valve
Product Information:
The JAYHAK96001A Regulated Natural to L.P.Gas Conversion Kit is designed for converting J962X two-stage gas valves to be used on L.P. gas applications. This conversion kit is suitable for use on all Two-Stage, fast and slow open models.
The kit includes the following components:
-
47 Drill Size Burner Orifice Kit
-
48 Drill Size Burner Orifice Kit
-
56 Drill Size Burner Orifice Kit
-
57 Drill Size Burner Orifice Kit
- 6 L.P. Regulator Springs
- 6 L.P. Labels
The kit also provides a High Altitude Derate Orifice Size Chart for both Natural and L.P. Gas, which includes the recommended orifice sizes based on different elevation levels.
Product Usage Instructions
- Step 1: Remove the original natural gas orifice counterclockwise using an adjustable wrench or electric screwdriver. Replace it with a liquefied petroleum gas orifice. Place the gas valve horizontally and unscrew the HI and LO pressure regulating screws.
- Step 2: Take out the plastic screws and the original natural gas spring. Place the liquefied petroleum gas spring in the middle.
- Step 3: Screw the HI and LO plastic screws clockwise for 14 turns or screw the plastic screws clockwise to the bottom, tighten it, and then rotate it counterclockwise for 2-3 turns.
- Step 4: Install the gas pipe assembly and gas valve. Connect the gas pressure gauge and check for gas leakage.
- Step 5: Adjust both outlet pressures to meet the appliance manufacturer’s requirements.
- Step 6: Attach the provided WARNING label to the gas valve where it can be readily seen. Also, attach the small round L.P. labels to the top of the regulator cover screws.
Note: Conversion back to Natural Gas use may be made at a later date by retaining the Natural Gas springs (removed in step 3) and following the same procedures.
If the converted L.P. low regulator setting is less than 5.0w.C., use the original natural gas spring.
Regulated Natural to L.P.Gas
Conversion Kit for Two-Stage Gas Valve
INSTALLATION INSTRUCTIONS
Installer: Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY INSTALLING OR OPERATING
THIS CONTROL COULD CAUSE INJURY AND/OR PROPERTY DAMAGE
WARNING
This conversion kit shall be installed by a qualified service agency in
accordance with the manufacturer’s instructions and all applicable codes and
requirements of the authority having jurisdiction.If the information in these
instructions is not followed exactly, a fire, explosion, or production of
carbon monoxide may causing property damage, personal injury , or loss of
life.The qualified service agency performing the work assumes the
responsibility for the proper conversion of this appliance with this kit.
APPLICATION
This conversion kit is only applicable to J962X two-stage gas valves to be used on L.P.gas applications. This conversion kit is for use on all Two-Stage, fast and slow open models.
Table 1. Kit Contents
DESCRIPTION | QTY |
---|---|
#47 Drill Size Burner Orifice Kit | 6 |
#48 Drill Size Burner Orifice Kit | 6 |
#56 Drill Size Burner Orifice Kit | 6 |
#57 Drill Size Burner Orifice Kit | 6 |
TO CONVERT FROM NATURAL
TO L.P.GAS
Step 1:
Remove the original natural gas orifice counterclockwise with an adjustable
wrench or electric screwdriver and replace it with a liquefied petroleum gas
orifice.
Place the gas valve horizontally, and unscrew the HI and LO pressure
regulating screw;
Step 2:
Take out the plastic screws and the original natural gas spring and place the
liquefied petroleum gas spring in the middle;
Step 3:
Screw the HI and LO plastic screws clockwise for 14 turns or screw the plastic
screws clockwise to the bottom, tighten it, and then rotate it
counterclockwise for 2-3 turns.
Step 4:
Install the gas pipe assembly and gas valve and connect the gas pressure
gauge, and then check the gas leakage.
Step 5:
Adjust both outlet pressures to the appliance manufacture’s requirements.
Step 6:
Attach the WARNING label(provided in the kit) to the gas valve where it can be
readily seen.Also attach the small round L.P. labels to the top of the
regulator cover screws.
Conversion back to Natural Gas use maybe made at a later date by retaining the Natural Gas springs(removed in step 3, above) and following the same procedures.
NOTE
If the converted L.P. low regulator setting is less than 5.0″w.C., use the
original natural gas spring.
WARNING
VALVE CONVERTED FOR USE ON L.P. GAS, IMPROPER OPERATION QULD RESULT IN DEATH
OR SERIOUS INJURY.
High Altitude Derate Orifice Size Chart (Natural and LP Gas*)
Input Rate|
Number of Burner
| Elevation(Ft)
---|---|---
KBtu/h| 0-2000| 2000-4000| 4000-6000| 6000-8000| 8000-10000
| Nat| LP| Nat| LP| Nat| LP| Nat| LP| Nat| LP
60| 3| 45| 55| 47| 56| 48| 57| 49| 58| 50| 59
80| 4| 45| 55| 47| 56| 48| 57| 49| 58| 50| 59
100| 5| 45| 55| 47| 56| 48| 57| 49| 58| 50| 59
120| 6| 45| 55| 47| 56| 48| 57| 49| 58| 50| 59
LP orifice based on 10 inWC manifold pressure
The input to the furnace must be checked AFTER reorificing.