SPY SHOP EUROPE SIM-03 Digital Quad Pir and Microwave Antimasking Detector Instruction Manual
- June 4, 2024
- SPY SHOP EUROPE
Table of Contents
SIM-03
DIGITAL QUAD PIR AND
MICROWAVE/ANTIMASKING
DETECTOR
INSTALLATION INSTRUCTIONS
P/N 7106777 Rev A
SIM-03 Digital Quad Pir and Microwave Antimasking Detector
Wide Angle Lens
AVOID THE FOLLOWING LOCATIONS:
- Facing direct sunlight.
- Facing areas that may change temperature rapidly.
- Areas where there are air ducts or substantial airflows.
- Avoid screens, and curtains that may block the detection area.
- Do not install outdoors.
SPECIFICATION
Detection Method
Power Input
Current Draw
Temperature
Compensation
Alarm Period
Alarm Output
with
protection
Tamper Switch
with
protectionWarm Up Period
LED Indicator
Dimensions
Weight
| PIR element
& microwave pulse Doppler
8.2 to 16 Vdc
Active : 25.5 mA
Standby: 16.5 mA
YES
2 +/- 1 sec
N.C 28Vdc 0.1 A
10 Ohm series
resistors
N.C 28Vdc 0.1A
10 Ohm series
resistor – open when
cover is removed
1 min
Yellow during warm-up and self-testing Red during alarm Green: PIR CHANNEL
Yellow: MW CHANNEL
---|---
INSTALLING THE DETECTOR
|
---|---
WIRE REQUIREMENTS
Use #22 AWG (0.5mm) or wires with a larger diameter. Use the following table
to determine the required wire gauge (diameter) and length of wire between the
detector and the control panel.
(Wire Length | m | 200 | 300 | 400 | 800 |
---|---|---|---|---|---|
Wire Diameter | mm | .75 | 1.0 | 1.5 | |
Wire Length | ft | 800 | 1200 | 2000 | 3400 |
Wire Gauge | # | 22 | 20 | 18 | 16 |
PCB LAYOUT
WIRE CONNECTIONS
Terminal 1 – Marked “ – ” (GND)
Connect to the negative Voltage or ground of the control panel.
Terminal 2 – Marked “ + ” (+12V)
Connect to a positive Voltage of 8.2 -16Vdc source.
Terminals 3 & 4 – Marked “ TAMP ”
If a Tamper function is required connect these terminals to a 24-hour normally
closed protective zone in the control unit.
Terminals 5 & 6 – Marked “ R-PIR ”
These are the output relay PIR contacts of the detector. Connect to a normally
closed zone in the control panel.
Terminal 7 – Marked “EOL”
End of the line option.
Terminals 8 & 9 – Marked “ R-AM ”
These are the output relay Anti Mask contacts of the detector. Connect to a
normally closed zone in the control panel.
DETECTOR SETTINGS
Switch 1: LED Control
Position Up – ON – LED ENABLE
Position Down – OFF – LED DISABLE
The LEDs are disabled (except “Anti Mask” mode).
Note: when an object is too close to the detector (depending on Switch 2 position), all three LEDs will blink together until the SIM-03 exits the Anti Mask.
LED INDICATORS:
YELLOW LED – MW detection
GREEN LED – PIR detection
RED LED – Alarm
Switch 2: Anti Mask function
Position Up – ON – protection against masking the detector from 0.4m and
closer.
Position Down – OFF – protection against masking the detector from 0.8m and
closer.
Switch 3: PULSE count function for PIR sensitivity. Position Down – OFF –
High sensitivity For stable environments.
Position Up – ON – Low sensitivity To harsh environments.
Switch 4: PET Immune function.
Position Up – ON – Immunity up to 15 kg
Position Down – OFF – Immunity up to 25 kg
YOU MUST RESET THE DETECTOR BY DISCONNECTING THE POWER SUPPLY AND RECONNECTING IT AFTER A FEW SECONDS.
RANGE ADJUSTMENT
PIR SENSITIVITY
Use the Potentiometer marked “PIR” to adjust the detection sensitivity between 15% and 100%, according to to walk test in the protected area.
The factory setting is 57%.
MW SENSITIVITY
The “MW” potentiometer adjusts the detection sensitivity of Doppler between
40% and 100% (factory set to 65%).
Rotate the potentiometer clockwise to increase sensitivity.
Rotate the potentiometer counter-clockwise to decrease sensitivity.
TESTING THE DETECTOR
Apply 12 Vdc power to the detector, and wait 2 minutes to finish the detector warm-up time. Conduct testing with the protected area cleared of all people.
Walk test
- Remove the front cover.
- Make sure that the PULSE switch is in position 1.
- Make sure that the LED switch is ON.
- Replace the front cover.
- Start walking slowly across the detection zone.
- Observe the detector’s LED lights whenever motion is detected.
- Allow 5 sec. between each test.
- After the walk test is completed, the LED and PULSE jumpers may be changed.
NOTE: Walk tests should be conducted, at least once a year, to confirm proper operation and coverage of the detector.