CALYPSO ULPWIREDMINI Ultra Low Power Ultrasonic Wired Mini Wind Meter User Manual

June 13, 2024
CALYPSO

CALYPSO ULPWIREDMINI Ultra Low Power Ultrasonic Wired Mini Wind Meter

WIND METERCALYPSO ULPWIREDMINI Ultra Low Power Ultrasonic Wired Mini Wind
Meter 1

If you want to know more about our new ULP Ultrasonic Wired Mini wind meter, please keep reading or visit our website www.calypsoinstruments.com

Product overview

Thank you for choosing the Ultra-Low-Power Ultrasonic Wired Mini wind meter from Calypso Instruments. This wind sensor is the first model or our generation II, representing an important technology breakthrough condensing an extensive R+D investment:

  • We feel very proud to release a unit that requires under 0.4 mA of power at 5V, sampling at 1Hz.
  • Different output options available: UART/I2C.

Package content
The package contains the following:

  • ULP Wired Mini Wind Instrument plus 2 meter (6.5 ft) cable for connection.
  • Serial number reference on the side of the packaging.
  • A quick user guide on the back of the packaging and some more useful information for the customer.
  • M4 screw (x3) ****

Technical specifications

The ULP Wired Mini has the following technical specifications:

  • Dimensions
    • Diameter 43 mm (1.69 in.)
    • Height: 47 mm (1.85 in.)
  • Weight ·78 grams (2.75 oz.)
  • Power  3.3- 5 DCV

CALYPSO ULPWIREDMINI Ultra Low Power Ultrasonic Wired Mini Wind Meter
3

The ULP Wired Mini has to be connected as shown in this section. ****

Data interface| 1Autotransmit

2-POLL telegram

---|---
Data format| UART
Baudrate| 1,200 to 115,200 (8n1) bauds
Voltage range| 3.3-5 VDC

Sensors

  • Ultrasonic transducers (4x)
  • Sample rate: 0.1 Hz to 10 Hz

The ULP Wired Mini has been designed to avoid any mechanical parts to maximize reliability and minimize maintenance. The transducers communicate between themselves two by two using ultrasonic range waves. Each pair of transductors calculates the signal delay and get information about both wind direction and wind speed.

It can be mounted either on a plate (inferior screws).

  • Easy mount – 3 x M4 base female tripod thread UNC 1/4” – 20

Mounting Instructions:
The ULP Wired Mini has a small circle on the outside of the main body which is called the north mark. The ULP Wired Mini should be mounted with the north mark facing the true north.

  • Firmware Upgradable via UART/TTL

Product Material

The ULP Wired Mini is engineered to be a robust device with minimal downtime. Frost, rain or snow might affect measurements if it blocks the wave path. The input wires are protected by Transient Voltage Suppression (TVS) diodes. The instrument body is built with Polyamide.

Quality Control

Every single unit is calibrated with accuracy, following the same calibration standards for each one in a wind tunnel. A Q/C report for both wind speed and direction is generated and kept in our files. Standard deviation is checked to guarantee that each unit has been calibrated to the highest standards.

Configuration Options

The ULP Wired Mini can be set up by using a special configuration app made by Calypso Instruments. In order to use the app, you should download theconfigurator from our website at www.- calypsoinstruments.com. To configure your device, connect the ULP Wired Mini via a USB to UART converter cable. Connect all the ULP cables except for the brown cable to the converter. Insert the USB into the computer, open the configurator app, select the configuration wanted and follow the instructions on the screen to finish the configuration. You will be prompted by the app to connect the brown wire at a specific moment of the configuration. For more information, please watch the following video. https://bit.ly/3DuA7lM
*USB converter cables available on calypsoinstruments.com

  • Baudrate: 2400 to 115200 (8n1) bauds
  • Output rate: 0.1 to 10 Hertz
  • Output units: m/sec., knots or km/h

CALYPSO ULPWIREDMINI Ultra Low Power Ultrasonic Wired Mini Wind Meter
5

Communication Protocols

UART Sentences
MWV Wind Speed and Angle
1 2 3 4 5
| | | | |
$–MWV,x.x,a,x.x,a*hh

  1. Wind Angle, 0 to 360 degrees
  2. Reference, R = Relative, T = True
  3. Wind Speed
  4. Wind Speed Units, K/M/N
  5. Status, A = Data Valid
  6. Checksum
    MWV Sentence 4800bps 8N1

General information

General recommendations
Regarding mounting the unit, align the north mark (the circle on the side) of the ULP Wired Mini towards the north. Make sure to install the sensor in a location free from anything that obstructs the flow of wind to the sensors within a 2 meter radius.

Maintenance and repair
The ULP Wired Mini does not require great maintenance thanks to the lack of the moving parts in this new design.Transducers must be kept clean and aligned. Impacts or incorrect impulsive handling may lead to transducers misalignment. The space around the transducers must be empty and clean. Dust, frost, water, etc… will make the unit stop working. The ULP Wired Mini can be wiped clean with a damp cloth being careful to not touch the transducers.

Warranty
This warranty covers the defects resulting from defective parts, materials and manufacturing, if such defects are revealed during the 24 months after the purchase date. Warranty is void in case of non-following the instructions of use, repair or maintenance without written authorisation.

Any wrongful use given by the user will not incur in any responsibility on part of Calypso Instruments. Therefore, any harm caused to the ULP Wired Mini by a mistake will not be covered by the waranty. Using assembly elements different from those delivered with the product will void the warranty. Changes on transducers position/alignment will void any warranty. For further information please contact Calypso Technical Support through aftersales@calypsoinstruments.com or visit www.calypsoinstruments.com.

Ultra-Low-Power Ultrasonic Wired Mini wind meter
User manual English version 1.0
07/03/2023

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>