CALYPSO ULTRASONIC ULP Ultra-Low-Power Ultrasonic Wind Meter User Manual

June 8, 2024
CALYPSO

CALYPSO-logo www.calypsoinstruments.com

CALYPSO ULTRASONIC ULP Ultra Low Power Ultrasonic Wind
Meter-

CALYPSO ULTRASONIC ULP Ultra Low Power Ultrasonic Wind Meter-
Fig1 ULTRASONIC ULP
User manual

If you want to know more about our new ULTRASONIC ULP wind meter, please keep reading or visit our website www.calypsoinstruments.com

Product overview

Thank you for choosing the ULP Ultrasonic Anemometer from Calypso Instruments. This ULP is the first model or our generation II, representing an important technology breakthrough condensing an extensive R+D investment:

  • Both shape andfirmware have been enhancedfor an improved rain performance,beingthis point key for static applications such as weather stations.
  • Mechanical design has been revamped making the unit more robust and dependable.
  • We feel very proud to release a unit that requires under 0,4 mA of power at 5V, sampling at 1Hz.
  • Different output options available: RS485 and UART/TTL

Applications for the ULP are the following:
Weather Stations | Drones
Temporary Scaffolding and construction |
Infrastructures and building | Cranes
Spraying | Irrigation | Fertilizing | Precision
Agriculture
Smart Cities | Wild fires | Shooting | Scientific

Package content

The package contains the following:

  • Ultrasonic Wired Wind Instrument + cable 2 meters for connection
  • Serial number reference in the back of the packaging
  • Quality control referece in the same place as the previous one. (Both shown in the Image 1)
  • User Quick guide at the back of the packaging and some more information useful for the customer.
  • Connection instructions picture including at the box package.
  • M4headless screw (x6)
  • M4 screw (x3)

CALYPSO ULTRASONIC ULP Ultra Low Power Ultrasonic Wind Meter-
Fig2

Technical specifications

ULP incorporates the following technical specifications:

CALYPSO ULTRASONIC ULP Ultra Low Power Ultrasonic Wind Meter-
Fig3

3.3. Power · 3,3-18V

ULP 485 has to be connected as is shown below:

CALYPSO ULTRASONIC ULP Ultra Low Power Ultrasonic Wind Meter-
Fig4

Image 5. Cable connections.

Data interface| 1-Stream output
2-POLL output
3- MODBUS
---|---
Data format| NMEA0183
Baudrate| 2400 to 115200 bauds
Voltage range| 3,3-18V

3.4. Sensors

  • Ultrasonic transducers (4x)
  • Sample rate: 0.1 Hz to 20 Hz

3.5. Wind

  • Windspeed
    information

  • Wind direction

The ULP has been designed to avoid any mechanical parts to maximize reliability and minimize maintenance.| Wind speed
Range: 0- 45 m/s
Accuracy: ±0.1 m/s at 10m/s
---|---
The transducers communicate between themsel – ves two by two using ultrasonic range waves. Each couple of transductors calculates the signal delay and gets information about both, wind direction and wind speed.| Wind direction
Range: 0- 360°
Accuracy: ± 1°

3.6 Easy mount

– 3 x M4 lateral female thread
– 3 x M4 inferior female thread

Lateral and inferior female thread. It can be mounted either on a plate (inferior screws) or on a tube (lateral screws).

CALYPSO ULTRASONIC ULP Ultra Low Power Ultrasonic Wind Meter-
Fig5

Mounting accessories

CALYPSO ULTRASONIC ULP Ultra Low Power Ultrasonic Wind Meter-
Fig6

3.7. Firmware

  • Upgradable via RS485 or UART/TTL

3.8. Limitations

ULP is engineered to be a robust device with minimal downtime. This new shape has been designed for optimum water spillage which implies lower probability of ice formation. Frost might affect measurements if it blocks the wave path.
The input wires are protected by Transient VoltageSuppression (TVS) diodes. Also, the instrumentbody is built in Polyamide.

3.9. Quality control

Every single unit is automatically calibrated on a wind tunnel. A Q/C report for both module and angle is generated and keptin our files. Standard deviation is checked to warranty that each unit is been calibrated to the hightest standards.

Configuration options

baudrate 2400 to 115200 (8n1 ) bauds
output rate: 0.1 to 20 Hz.
output units: m/scc., Knots or Km/h.
The Ultrasonic ULP can be set up by using a special App made by Calypso Instruments.
In order to use the APP you should download the following documentation:
Ultrasonic ULP configurator.exe

CALYPSO ULTRASONIC ULP Ultra Low Power Ultrasonic Wind Meter-
Fig7

General information

5.1. General recommendations
As described previously is important to understand that the unit can be mounted directly on a pole or using a flat bracket. In either case make sure the north mark is perfectly aligned.

Then install the sensor in a location free from wind perturbation.
Other important aspects

  • Do not try to modify by any case the unit.
  • Avoid touching the transducers
  • Do not modify/customizethe surfaceof the unit.

If you have any questions or doubts, please contact directly with us. We will be glad to assist you in any time.

5.2. Maintenance and repair
Thanks to the mechanical simplicity the ultrasonic does not require mechanical maintenance.
Transducers must be kept clean and alignedImpacts or incorrect impulsive handling may leadto transducers misalignment.
The space in between the transducers and its reflection surface must be empty and clean. Dust,frost, water, etc… will make the unit stop working. Rinse with fresh water and let it dry.
5.2. Warranty
Warranty is void in case of no-nfollowing the instruct ions of use, repair or maintenancewithout  written authorization.Every Calypsoproduct offersa 2-Year PerformanceWarranty.
Calypso Instruments shall not be liable for any damages arising out of:
-Exposition of the Ultrasonic at temperatures out of the range stated above.
– Transducers misalignment or damage dueto external impact.
– Solarcell damagedue to removingthe protecting film.
– Geometry changes on the flow channel due to external actions.
– Use inappropriatevoltages.
– Do not installed the ultrasonic as stated above which causes damage on the ultrasonic.
You can return unopened items in the original packaging within 30 days of your purchase with proof of purchase. Upon receipt of the returned item, we will fully examineit andnotify you viaemail, within a reasonable period of time on the status. If we decide a return is appropriate, we will refund your purchase price and a credit will be applied to
your original method of payment.

For further information please contact Calypso
Technical Support through
aftersales@calypsoinstruments.com
or visit www.calypsoinstruments.com .
Calypso Instruments team thanks you for your confidence.

CALYPSO-logoC/Alfonso Sotans 20, local 12
5014 – Zaragoza
Spain
Telephone number: +34 976 291 839
E-mail: sales@calypsoinstruments.com
aftersales@calypsoinstruments.com
Calypso Instruments is a Trademark of Prodeo Ingenieria y Consultoria
ULTRASONIC ULP
User manual English version 2.1
15/02/2021

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals