INSTALLATION

STEP 1 Prepare for Installation
  1. Turn off COLD water valve. Release pressure from system by turning on dedicated faucet until water stops flowing.
  2. Unbox filter cartridge replacements and remove plastic.
STEP 2 Remove Filter Cartridges
  1. Remove Stage 1 and Stage 3 sumps from the system manifold by rotating the sumps to the left and pulling down.
  2. Holding the sumps over the sink, unscrew the top of the sump from the bottom by turning the bottom portion to the left. Pour excess water down the drain. Then, pull down on each filter cartridge to disconnect the filter cartridge from the top half of the sump.
  3. Discard both filter cartridges.

Note: If sumps are too tight to disconnect by hand, please use plastic wrench provided with original system.

Remove Filter Cartridges

STEP 3 Attach Cartridges
  1. Press new filter with clear netting to the top of Stage 1 sump. Reattach the bottom of the sump by ensuring connection points are correctly aligned, then turn to the right to tighten.

  2. Continue this step for Stage 3 using the new filter with the blue netting.
    Note: Do not use tools to tighten. Hand tighten only.

  3. Set aside Stage 1 and Stage 3 sumps and follow steps 4-5 to change the Remineralizer. To prevent water from flowing, do not reattach Stage 1 and 3 at this time.

STEP 4 Remove Remineralizer
  1. Remove the 3/8″ hose from the inlet and outlet of the Remineralizer by pushing and holding down the collar while removing the hose. Discard remineralizer.
    Note: Be sure red tube and elbow are inserted all the way
STEP 5 Reconnect Tubing and Insert New Remineralizer
  1. Insert the white 3/8″ hose attached to the faucet into the outlet connection of the new Remineralizer by pressing the hose in until it stops.
  2. Connect the remaining hose end (which has the opposite end connected to the RO Manifold outlet labeled “Faucet”) to the inlet portion of the Remineralizer by pressing the hose in until it stops.

STEP 6 Reattach Sumps

  1. Reattach sumps to the system manifold with Stage 1 on the left and Stage 3 on the right to the top housing. Ensure all connection points are aligned. Push the top of the sump into the bottom of the top housing and turn the sump to the right. Ensure the sump is fully attached and locked into Stage 1 on the left and Stage 3 on the right.
    Note: Ensure sumps are not on an angle while reattaching. This may result in damage to the o-ring.
STEP 7 Flush and Check for Leaks
  1. Slowly turn on the cold water valve. Turn off the dedicated faucet and allow water tank to refill completely.
    Note: It will take 2 hours for the water tank to refill.

  2. Once the tank has completely filled, inspect for leaks. If there are no leaks, flush the filter cartridges by turning on the dedicated faucet and allowing the water to run through the system until there is no pressure coming out of the dedicated faucet.
    Note: Do not drink flushed water.

  3. Turn off the dedicated faucet and allow 2 hours for the pressure to build in the system. Once complete, your system is ready for use.

CARE & SAFEGUARDS

Care
To clean system manifold, wipe exterior with a damp cloth. Do not use any strong abrasive
cleaning agent or solvent cleaner.
NOTICE
Safeguards

  • If you experience a hose connection leak, disconnect and re-set the hose.
  • Must replace filter housings every 5 years or risk property damage from leaks. Call 800.821.2017 to order.
  • Do not use with water that is microbiologically unsafe or of unknown water quality without adequate disinfection before or after the system.
  • Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.

Scan to view the AO-US-RO-MB-R replacement video.
QR-code

System certified by IAPMO R&T against NSF/ANSI Standards 42, 53, 401 for reduction of claims specified on Performance Data Sheet and at www.IAPMO.com. Conforms to NSF protocol P472 and P231 as verified and substantiated by test data.

  • Rated capacity: 365 gallons (1,382 liters)
  • Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.

For the full list of contaminants filtered, scan to view the AO-US-RO-MB-4000 Performance Data Sheet.
QR-code

Customer Support

A. O. Smith Corporation
11270 W Park Pl #170, Milwaukee, WI 53224
877.333.7108

AO Smith-Logo

Documents / Resources

| AO Smith AO-US-RO-MB-4000 Claryum Carbon Microbial and Remineralizer Filters [pdf] Installation Guide
AO-US-RO-MB-4000 Claryum Carbon Microbial and Remineralizer Filters, AO-US-RO- MB-4000, Claryum Carbon Microbial and Remineralizer Filters, Microbial and Remineralizer Filters, Remineralizer Filters
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals