RISK OF FIRE – Required clearance from structural members and building elements
Side Clearance from heatsink to building element (e.g. timber, joist or batten) (SCB): 100mm
Height Clearance from heatsink to building element (e.g. timber, joist or batten) (HCB): 100mm

Recessed Luminaire Classification:

NON-IC – A luminaire shall under no circumstances be covered or abutted with building insulation.

If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similarqualified person in order to avoid a hazard.

The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced

DO NOT INSTALL THROUGH JOIST, BEAM, RAFTER OR CEILING BATTEN

All exterior luminaires (with the exception of copper) require periodic cleaning to protect the surface and/or coating from corrosion and ensure tidy appearance for the lifespan of the product. Wash with care using a soft brush and warm soapy water using a neutral detergent. Coastal areas require extra attention, especially fittings which are under eaves/soffits and do not have any exposure to rain. Do not use a water blaster or high pressure hose, do not submerge fittings for extended periods of time. 316 stainless steel fittings will still develop surface rust or “tea staining” if left uncared for.

Concrete Installation

Concrete Installation

FIG-1-A2
Concrete Installation

FIG-1-A3
Concrete Installation

FIG-1-A4
Concrete Installation

FIG-1-A5
Concrete Installation

Exterior soffit installation

FIG-1-B2

FIG-1-B3
Exterior soffit installation

FIG-2
Exterior soffit installation

Manufacturer / Supplier Halcyon Lighting Ltd
Product Code R836
Product Type LED Recessed Luminaire
Secondary Voltage 700mA Constant Current
Wattage 25.5W
Ingress Protection Rating IP65
Classification ****

covered or abutted with building insulation.
---|---|---

DO NOT INSTALL THROUGH JOIST, BEAM, RAFTER OR CEILING BATTEN.

Side Clearance from heatsink to building element (e.g. timber, joist or batten)| SCB:100mm
---|---
Height Clearance from heatsink to building element (e.g. timber, joist or batten)| HCB:100mm
Side Clearance from heatsink to insulation| SCI: 100mm
---|---
Height Clearance from heatsink to insulation| HCI: 100mm

Caution: Recessed luminaires and their associated equipment may pose a risk of fire or damage to property if not installed and maintained correctly.

Halcyon Non IC rated luminaires are completely safe to install in sarked timber ceiling linings with a gauge of less than 20mm. Halcyon accepts no responsibility if the timber used is not treated correctly and dries out, crack or warps over time due to the constant low heat from the aforementioned “Non IC Rated” LED recessed lighting.

This data sheet contains information necessary to ensure compliance with the New Zealand Electrical Code of Practice for Installation and Maintenance of Recessed Luminaires and Associated Equipment AS/NZS 60598.2.2:2001

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

HALCYON User Manuals

Related Manuals