TECHNICAL SPECIFICATIONS
SCE Series
Indoor, Separated Combustion,
Gas-Fired, Factory-Connected
Duct Furnace/Blower Unit for
Commercial/Industrial Heating and
Makeup Air
150 SCE Series Duct Furnace/Blower Unit for Commercial/Industrial
Heating and Makeup Air
Renzo Model SCE is a factory-connected assembly of a separated combustion duct
furnace and blower cabinet. Sizes are available with heating capacities from
125,000 through 400,000 BTUH gas input. The standard package is a heating-only
system, but factory-installed gas and inlet-air control options are available
to meet makeup air or combination heating/makeup air specifications. This
system is designed for use in building areas with negative pressure and/or
extremely dirty or mildly corrosive atmospheres.
Model SCE is available for use with either natural or propane gas, as
specified. All units are equipped with required limit and safety controls.
The duct furnace in this factory-connected system is designed to separate
combustion air from the air in the heated space. The furnace is engineered and
manufactured in accordance with the ANSI definition of “separate combustion.”
While discharging exhaust air, the power venter draws in combustion air from
the outside atmosphere. Exclusive outside combustion air prevents dirt, lint,
dust or other contaminants in the heated space from entering the combustion
zone of the furnace.
A specially designed combustion-air inlet/vent terminal assembly is required.
This specially designed concentric terminal assembly requires only one
building penetration.
Model SCE units are design-certified by the Canadian Standards Association for
installation in the U.S. and Canada.
FEATURES and BENEFITS
- Orifices for natural gas
- Aluminized steel heat exchanger (see note 2)
- Aluminized steel burners with a stainless steel insert
- 115-volt power supply
- Open drip-proof blower motor with internal overloads
- Motor contactor
- 115-volt venter motor with stainless steel shaft
- 24-volt control transformer
- Redundant single-stage combination gas valve (see note 1)
- Intermittent spark safety pilot
- Fan and limit safety controls
- Differential air pressure switch to verify vent flow
- Adjustable belt drive
- Terminal block wiring
- Left side controls (left when facing air discharge)
- Horizontal discharge air opening with duct flanges
- Blower cabinet (less optional filter rack and filters) with horizontal inlet-air opening (without duct flange)
- Threaded suspension couplings (4 – 1” IPS)
OPTIONAL FEATURES
-
Unit equipped for propane gas
-
E-3 (409) stainless steel heat exchanger
-
321 stainless steel heat exchanger
-
E-3 (409) stainless steel burners
-
E-3 (409) stainless steel drip pan
-
Intermittent spark safety pilot with timed lockout – must be used with units burning propane
-
1/4 HP through 5 HP open drip-proof motors
-
1/4 HP through 3 HP totally enclosed blower motor
-
208/1, 230/1, 208/3, 230/3, 460/3, 575/3 voltage alternates
-
Motor starter
-
Burner air shutters (required for units equipped for propane gas)
-
Two-stage gas control (unit-mounted or remote temperature selector)
-
Electronic modulation, 50%-100% turndown or 20%-100% turndown
-
Makeup air controls/dampers
-
1/2” O.D. BX cable (Chicago code)
-
Expanded metal safety screen for inlet air opening
NOTES:
1. Regulated combination redundant gas valve consists of combination pilot solenoid valve, electric gas valve, pilot filter, pressure regulator, pilot shutoff, and manual shutoff, all in one body. Gas supply pressure must not exceed 0.5 PSI (8 oz. – 14” W.C.). Minimum inlet pressure for natural gas is 5” W.C. Minimum inlet pressure for propane gas is 11” W.C.
2. For air inlet temperatures below 40°F or temperature rise less than 40°F, optional stainless steel heat exchanger is recommended.
3. Not certified for residential use. -
Firestar(s)
-
Freeze stat(s)
-
Manual summer/winter switch
-
Filter rack with disposable, pleated or permanent filters (1 or 2 inch)
-
Louver frame with horizontal discharge louvers
-
Louver frame with horizontal and vertical discharge louvers
-
Summer/winter relay (thermostat with fan switch shipped separately)
-
Insulated blower cabinet
-
Bottom return air inlet
-
Blower cabinet horizontal inlet w/duct flange
-
Right side controls (facing airstream)
ACCESSORIES – FIELD INSTALLED
- Horizontal or vertical vent terminal/combustion air inlet assembly (installation requirement)
- Condensate drain flange kit
- Disconnect switch (fusible/non-fusible) – UL Listed
- Single-stage thermostat
- Two-stage thermostat
- Electronic 7-day programmable thermostat
- Remote control center
- Manual shutoff valve and union
MODEL IDENTIFICATION CODES
TECHNICAL DATA
SI| 1| 1| 571| 0 2 0| 2 2 5|
2| 3| 3| 0 4 0
---|---|---|---|---|---|---|---|---|---
Heating
Input
| BTUH| 125,000| 150,000| 175,000| 200,000| 225,000| 250,000| 300,000|
350,000| 400,000
kW| 36.6| 44.0| 51.3| 58.6| 65.9| 73.3| 87.9| 102.6| 117.2
Thermal Output
Capacity A
| BTUH| 97,500| 120,000| 136,500| 160,000| 175,500| 200,000| 234,000|
273,000| 312,000
kW| 28.6| 35.2| 40.0| 46.9| 51.4| 58.6| 68.6| 80.0| 91.4
Unit Amps – 115V (Less Motor)| 1.9| 1.9| 1.9| 1.9| 1.9| 1.9| 1.9| 1.9|
1.9
Control Amps (24V)| 0.95| 0.95| 0.95| 0.95| 0.95| 0.95| 0.95| 0.95| 0.95
Air Volume| CFM| 1,000-3,000| 1,230-3,700| 1,400-4,210|
1,640-4,935| 1,800-5,150| 2,050-5,800| 2,400-6,300| 2,800-6,800| 3,200-7,100
m 3/hr| 1,699-5,097| 2,090-6,286| 2,379-7,153| 2,786-8,384| 3,058-8,750|
3,483-9,854| 4,077-10,703| 4,757-11,553| 5,437-12,063
Net Weight| lbs.| 313| 358| 358| 382| 382| 482| 482| 498| 560
kg| 142| 162| 162| 173| 173| 219| 219| 226| 254
Ship Weight| lbs.| 375| 440| 440| 520| 520| 645| 645| 695| 716
kg| 170| 200| 200| 236| 236| 293| 293| 315| 325
Gas Connection—Natural B| 1/2”| 1/2”| 1/2”| 1/2”| 1/2”| 1/2”|
3/4”| 3/4”| 3/4”
Maximum C Vent Length| 6” Pipe| 50′| 50′| 50′| 50′| 50′|
50′| 50′| 30′| 30′
7” Pipe| N/A| N/A| N/A| 70′| 70′| 70′| 70′| 70′| 70′
Filter Size D (Filters Optional)| (2) 20 x 20| (2) 20 x 25|
(2) 20 x 25| (2) 16 x 20
(2) 16 x 25| (2) 16 x 20
(2) 16 x 25| (2) 20 x 20
(2) 20 x 25| (2) 20 x 20
(2) 20 x 25| (1) 20 x 20
(3) 20 x 25| (3) 16 x 25
(2) 20 x 25
A In U.S. ratings are for altitudes to 2,000 feet. Above 2,000 feet, dated by
orifice change, 4% for each 1,000 feet above sea level. In Canada ratings are
for altitudes o 2,000 feet. High altitude units (2,000 – 4,500 feet) date by
10% of maximum input.
B Sizes shown are for natural gas connections, NOT supply line size. Gas
connection for propane is 1/2 inch for all sizes.
C Minimum vent length is 5 feet. Seven inch pipe requires four field-supplied
tapered reducers.
D Optional filter rack will accommodate 1” or 2” filters.
DIMENSIONS STANDARD SCE SERIES 6
CLEARANCE FROM COMBUSTIBLES
- Top, flue, side opposite controls – 6”
- Control side – width of unit plus 6”
- Bottom – 6”
DIMENSIONS – WITH OPTIONAL HORIZONTAL INLET WITH DUCT FLANGES AND RETURN AIR OPENIN G
Air Openings | Dimensions |
---|---|
Standard Horizontal Air Inlet | H x N |
Optional Horizontal Air Inlet with Duct Flange | J x 19-1/2″ |
Optional Return Air Opening (bottom) | J x 19-1/2″ |
Standard Horizontal Discharge-Air Opening | D x 18″ |
DIMENSIONS (+ or – 1/8” or 3mm)
SIZE| A| B| D| E| F| G| H| J|
K| L| M| N
---|---|---|---|---|---|---|---|---|---|---|---|---
in.| mm| in.| mm| in.| mm| in.| mm|
in.| mm| in. **| mm| in.| mm| in.| mm|
in.| mm| in.| mm| in.| mm| in.| mm
125| 32 1/4| 819| 25 1/4| 641| 15 1/4| 387| 8 1/8| 206| 16 1/4| 413| 7|
178| 17 3/4| 451| 17 3/8| 441| 17| 432| 1/2| 13| 40 1/4| 1022| 27 3/4| 705
150, 175| 32 1/4| 819| 30 3/4| 781| 20 3/4| 527| 8 1/8| 206| 21 3/4|
552| 7| 178| 23 1/4| 591| 22 7/8| 581| 18 3/8| 467| 1/2| 13| 39| 991| 27 3/4|
705
200, 225| 35 1/4| 895| 36 1/4| 921| 26 1/4| 667| 10 3/4| 273| 27 1/4|
692| 10| 254| 28 3/4| 730| 28 3/8| 721| 17| 432| 1/2| 13| 40 1/4| 1022| 30
3/4| 781
250| 35 1/4| 895| 43 1/2| 1105| 33 1/2| 851| 9 3/4| 248| 34 1/2| 876| 9|
229| 36| 914| 35 5/8| 905| 16| 406| 1/2| 13| 39 1/4| 997| 29 3/4| 756
300| 35 1/4| 895| 44 1/2| 1130| 34 1/2| 876| 10 3/4| 273| 35 1/2| 902|
10| 254| 37| 940| 36 5/8| 930| 17| 432| 3/4| 19| 40 1/4| 1022| 30 3/4| 781
350| 35 1/4| 895| 50| 1270| 40| 1016| 10 3/4| 273| 41| 1041| 10| 254| 42
1/2| 1080| 42 1/8| 1070| 18 3/8| 467| 3/4| 19| 39| 991| 30 3/4| 781
400**| 35 1/4| 895| 55 1/2| 1410| 45 1/2| 1156| 10 3/4| 273| 46 1/2| 1181|
10| 254| 48| 1219| 47 5/8| 1210| | | | | | | |
NOTES:
- Burner and control access shown left side (left when facing air discharge). Specify right side for opposite access and connections (Option AJ2).
- See vent arrangement information.
- Standard SCE Blower Cabinet will not accommodate dampers. For dampers, select from AR Options.
GENERAL INFORMATION
WARNING: Gas-fired appliances are not designed for use in hazardous
atmospheres containing flammable vapors or combustible dust, or atmospheres
containing chlorinated or halogenated hydrocarbons.
Installations in public garages or airplane hangars are permitted when in
accordance with ANSI Z223.1 and NFPA 54 codes or CAN1-B149 and enforcing
authorities.
FOR YOUR SAFETY
What to do if you smell gas:
- Do not try to light any appliance.
- Do not touch any electrical switch; do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, immediately call your fire department.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
WARNING: Improper installation, adjustment, alteration, service, or
maintenance can cause property damage, injury, or death. Read the
installation, operation, and maintenance instructions thoroughly before
installing or servicing this equipment.
Requirements for installation vary depending on the model of heater and the
type of installation.
Follow the manufacturer’s instructions and comply with all applicable codes.
For complete catalog information including submittals, energy calculations,
dimension drawings, and more go to
www.ReznorHVAC.com or call
800-695-1901.
Note: In keeping with our policy of continuous product improvement, we
reserve the right to alter, at any time, the design, construction, dimensions,
weights, etc., of equipment information shown here.
© 2022 Nortek Global HVAC, LLC.
Reznor is a registered trademark of Nortek Global HVAC, LLC.
All other trademarks are the property of their respective owners.
All rights Reserved. Printed in U.S.A.
885F-0922
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>