  TERMINATION INSTRUCTIONS

Patch Panels Cat 6A Right Angle

Ultima Cat6A Patch Panels Termination 01 Ultima
Cat6A Patch Panels Termination 02

798926                          822781

1. Remove the patch panel cover and the cable earth clamps.

Ultima Cat6A Patch Panels Termination A01

2. Remove approximately 60mm of the cable sheath, cut back the rip cord and separate the 4 pairs.

Ultima Cat6A Patch Panels Termination A02

3. Identify the blue pair and carefully open 4. the foil. Fold this foil back along the outside of the cable sheath with the silver surface on the outside. Wrap the drain wire around the outside of the foil and sheath.

Ultima Cat6A Patch Panels Termination A03

4. Dress the wires in to the appropriate coloured IDC slots following the preferred wiring configuration. For the best performance results ensure that the cable pair foils are maintained as close as possible to the point of termination.

Ultima Cat6A Patch Panels Termination A04

5. Punch down the wires using a Krone type  or 110 style termination tool.

Ultima Cat6A Patch Panels Termination A05

6. When adjacent cables have been terminated fit the shield clamp taking care not to over tighten the screw and crush the cables.

Ultima Cat6A Patch Panels Termination A06

7. Secure the cables to the cable management using cable ties, taking care not to over tighten them.

8. When all of the cables have been terminated refit the patch panel cover. Make sure that the panel is connected to the cabinet or rack earth using the drain wire provided.

Ultima Cat6A Patch Panels Termination A08

Recommended Tools
Part Number Description Purpose
785125 Phillips Screwdriver 80mm Removal & fitting of cable earth clamps
786575 Side Cutters – 145mm Cutting cable to length and trimming cable ties
993874 Cyclops Stripper Cutting sheath
785404 Electronic Flush Cutters Cutting foils
773118 Inserter Wire 2A Terminating and trimming wires
770218 Inserter Wire 110 Terminating and trimming wires

Head office: Cardinal Way, Cardinal Distribution Park, Godmanchester, Huntingdon, PE29 2XJ
Tel: +44 (0)1480 1480 415400 Fax: +44 (0)1480 454724 Email: sales@ultima- comms.com Web: www.ultima-comms.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals