Current IND227 Lumination LED Luminaire LED Wall Washer Installation Guide
- June 13, 2024
- current
Table of Contents
Current IND227 Lumination LED Luminaire LED Wall Washer
Product Information
- Product Name: LED Wall Washer UL/CE Version (LW Series)
- Model Number: IND227
- Manufacturer: LED.com
- Maximum length of electrical run for UL version: – 5W: 120V – 156V – 8W: 97V – 340V
- Maximum driver current through connected fixtures should not exceed 6.5A for UL version.
- Maximum length of electrical run for CE version: – 5W: 240V – 8W: 96V
- Maximum driver current through connected fixtures should not exceed 2A for CE version. – The luminaire should be connected to the mains supply according to its ratings on the product label. – If the external flexible cable or cord of the luminaire is damaged, it should be replaced by a special cord exclusively available from the manufacturer or service agent. – The product should be kept in its bag until it is installed and powered. – Refer to the technical data sheet and dimmer specification for electrical properties and safe installation.
Product Usage Instructions
- Before starting the installation, read the instructions completely and carefully.
- Connect the LED wall washer to the mains supply according to its ratings mentioned on the product label.
- If the external flexible cable or cord of the luminaire is damaged, replace it with a special cord available exclusively from the manufacturer or service agent.
- Keep the product in its bag until it is installed and powered to protect it.
- For UL version: -Ensure that the maximum length of electrical run for fixtures does not exceed the specified values for different wattages and voltages. – The maximum driver current through connected fixtures should not exceed 6.5A.
- For CE version: – Ensure that the maximum length of electrical run for fixtures does not exceed the specified values for different wattages and voltages. – The maximum driver current through connected fixtures should not exceed 2A. 7. Refer to the technical data sheet and dimmer specification for detailed electrical properties and safe installation guidelines.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING
-
RISK OF ELECTRIC SHOCK
Turn power off before inspection, installation or removal. -
RISK OF ELECTRIC SHOCK
- Follow all NEC or IEC and local building codes.
- Use only UL and IEC approved wire for input/output connections. Minimum size 16 AWG (1.31 mm2).
- Double check wire gauge sizes for continous runs – if applicable.
-
The LED luminaire must be connected to the mains supply according to its ratings on the product label.
- If the external flexible cable or cord of this luminaire is damaged, it shall be replaced by a special cord or cord exclusively available from the manufacturer or his service agent.
- To protect product keep the bag on until it is installed and powered.
IMPORTANT
Maximum length of electrical run [fixtures] for UL version
[V] 5W | 8W |
---|---|
120 | 156 |
277 | 340 |
Under any circumstance, maximum driver current through connected fixtures
shall not exceed 6.5A for UL version.
Please see technical data sheet and dimmer specification for electrical
properties to ensure safe installation
Maximum length of electrical run [fixtures] for CE version
[V] 5W 8W
240| 96| 60
Under any circumstance, maximum driver current through connected fixtures
shall not exceed 2A for CE version.
Please see technical data sheet and dimmer specification for electrical
properties to ensure safe installation
Installation Guide
For UL version only. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class [A] RFLD complies with the Canadian standard ICES-003. Ce DEFR de la classe [ A ] est conforme à la NMB-003 du Canada. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Max. n (UL)
[V] 5W | 8W |
---|---|
120 | 156 |
277 | 340 |
Max. n (CE)
[V] 5W 8W
240| 96| 60
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. Information and
specifications subject to change without notice. All values are design or
typical values when measured under laboratory conditions.
(Rev 05/30/23)
IND227-Lumination-LLW-Series-LED-Wall-Washer-Installation-Guide_R01
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>