Features

  • Compact size and light weight
  • True sine wave output (THD<3%)
  • High surge power up to 800W
  • 250W convection, 400W forced air
  • AC output voltage and frequency selectable by DIP S.W
  • No load disspation <1.5W max. at standby saving mode
  • -20°C~+70°C wide operating temperature
  • Power ON-OFF remote control
  • Protections:
  • Input : Reverse polarity / DC low alarm / DC low shutdown / Over voltage
  • Output : Short circuit / Overload / Over temp.
  • Battery over discharge protection (Low voltage disconnect)
  • Suitable for lead-acid or li-ion batteries
  • Support Tx/Rx for monitoring power inverter status
  • Conformal coating
  • 3 years warranty

Description

NTS-400P is a 400W highly reliable built-in type off-grid true sine wave DC-AC power inverter. Its key features include: digital design with MCU control, streamlined control circuitry that quickly responds to environmental changes and improves reliability, compact size, light weight, 800W peak power, adjustable AC output voltage and frequency, -20~+70°C wide operating temperature range, built-in remote ON/OFF control, low no-load power consumption (energy saving mode < 1.5W max.), complete protection features, and etc. Combined with batteries, the NTS-400P is suitable for use in residential, commercial, marine, automobile, and remote areas with no access to utility power, and the output can be used to power fans, TV, radio, phone charger, PC/laptop, lighting, outdoor camping equipment, marine AC power, and etc.

Applications

  • Mobile device
  • Home and office appliance
  • Portable equipment
  • Vehicle
  • Yacht
  • Off-grid solar power system
  • Wireless network
  • Telecom or datacom system

GTIN CODE

Model Encoding

MEAN-WELL-NTS-400P-Series-True-Sine-Wave-DC-AC-Power-Inverter-
FIG-5

SPECIFICATION

MODEL NO.| NTS-400P-112| NTS-400P-124| NTS-400P-148| NTS-400P-212| NTS-400P-224| NTS-400P-248
---|---|---|---|---|---|---








AC OUTPUT

| RATED POWER(Continuous)| 400W
OVER RATED POWER(3 Min.)| 460W
PEAK POWER(10 Sec.)| 600W
SURGE POWER(30 Cycles)| 800W


AC VOLTAGE

| Default setting set at 110VAC| Default setting set at 230VAC
100 / 110 / 115 / 120Vac selectable by DIP S.W| 200 / 220 / 230 / 240Vac selectable by DIP S.W


FREQUENCY

| Default setting set at 60Hz±0.1Hz| Default setting set at 50Hz±0.1Hz
50/60Hz selectable by DIP S.W| 50/60Hz selectable by DIP S.W
WAVEFORM Note.1| True sine wave (THD<3%)
AC REGULATION| ±3.0% at rated output voltage
LED STATUS| Please refer to page3






DC INPUT

| DC VOLTAGE| 12V| 24V| 48V| 12V| 24V| 48V
VOLTAGE RANGE (Typ.)| 10 ~ 16.5Vdc| 20 ~ 33Vdc| 40 ~ 66Vdc| 10 ~ 16.5Vdc| 20 ~ 33Vdc| 40 ~ 66Vdc
DC CURRENT (Typ.)| 40A| 20A| 10A| 40A| 20A| 10A
NO LOAD DISSPATION

(Typ.)

| Non-Saving mode| 10W| 10W| 12W| 10W| 10W| 12W


Saving mode

| Default disable, ≦1.2W ~ 1.5W by models @ auto detec AC output load ≦10W will be changed to saving mode
1.2W| 1.3W| 1.5W| 1.2W| 1.3W| 1.5W
OFF MODE CURRENT DRAW| <1mA at battery ~DC input must be disconnected
EFFICIENCY (Typ.) Note.1| 89%| 91%| 91%| 91%| 93%| 93%
BATTERY TYPES| Lead Acid or Li-ion


PROTECTION

| DC INPUT| FUSE(Internal)| 40A2| 30A2| 10A2| 40A2| 30A2| 10A2


LOW

| ALARM| 11±0.3Vdc| 22±0.5Vdc| 44±1Vdc| 11±0.3Vdc| 22±0.5Vdc| 44±1Vdc
SHUTDOWN| 10±0.3Vdc| 20±0.5Vdc| 40±1Vdc| 10±0.3Vdc| 20±0.5Vdc| 40±1Vdc
RESTART| 12.5±0.3Vdc| 25±0.5Vdc| 50±1Vdc| 12.5±0.3Vdc| 25±0.5Vdc| 50±1Vdc


HIGH

| ALARM| 15.5±0.3Vdc| 31±0.5Vdc| 62±1Vdc| 15.5±0.3Vdc| 31±0.5Vdc| 62±1Vdc
SHUTDOWN| 16.5±0.3Vdc| 33±0.5Vdc| 66±1Vdc| 16.5±0.3Vdc| 33±0.5Vdc| 66±1Vdc
RESTART| 15±0.3Vdc| 30±0.5Vdc| 60±1Vdc| 15±0.3Vdc| 30±0.5Vdc| 60±1Vdc
BAT. POLARITY| By internal fuse open
AC OUTPUT| OVER TEMPERATURE| Protection type : Shut down o/p voltage, re-power on to recover
OUTPUT SHORT| Protection type : Shut down o/p voltage, re-power on to recover


OVER LOAD (Typ.)

| 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
Protection type : Shut down o/p voltage, re-power on to recover


FUNCTION

| REMOTE CONTROL| Power ON-OFF remote control by front panel dry contact connector (by RELAY), Open : Normal work ; Short : Remote off
Tx/Rx| Support Tx/Rx for monitoring power inverter status



ENVIRONMENT

| WORKING TEMP.| -20 ~ +70℃(Refer to “Derating curve”)
WORKING HUMIDITY| 20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -30 ~ +70℃ / -22 ~ +158oF, 10 ~ 95% RH non- condensing
VIBRATION| 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes








SAFETY

& EMC

( Note.4)

| ****

SAFETY STANDARDS

| CB IEC62368-1 for all models; E13, EAC TPTC004, AS/NZS 62368.1 for NTS- 400P-212/224/248 approved

(Please refer to next page “Safety overview” table for more details)

WITHSTAND VOLTAGE| DC I/P – AC O/P:3.0KVac AC O/P – FG:1.5KVac




EMC EMISSION

| Parameter| Standard| Test Level / Note


Radiated

| FCC for 112,124,148 only| Class A
BS EN/EN55032(CISPR32) for 212,224,248 only| Class A
Harmonic Current| BS EN/EN61000-3-2| —–
Voltage Flicker| BS EN/EN61000-3-3| —–




EMC IMMUNITY

| BS EN/EN55024, BS EN/EN55035
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 4, 15KV air ; Level 4, 8KV contact
Radiated| BS EN/EN61000-4-3| Level 3, 10V/m
Magnetic Field| BS EN/EN61000-4-8| Level 4, 30A/m


OTHERS

| MTBF| 836.2K hrs min.        Telcordia TR/SR-332 (Bellcore) ;    84K hrs min.        MIL-HDBK-217F (25℃)
DIMENSION| 186100.532mm (LWH)
PACKING| 0.75Kg; 18pcs/ 14.5Kg/ 1.01CUFT




NOTE

| 1. Efficiency, AC regulation and THD are tested by 400W, linear load at 12.5Vdc/25Vdc/50Vdc input voltage.

2. All parameters not specified above are measured at rated load, 25℃ of ambient temperature and set to factory setting. 3.Internal pre-start circuit, the setup time is 8s.

4.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”

(as available on http://www.meanwell.com)

※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Safety Overview

MODEL NO. Certificate
NTS-400P-112/124/148 __

NTS-400P-212/224/248|

Block Diagram

MEAN-WELL-NTS-400P-Series-True-Sine-Wave-DC-AC-Power-Inverter-
FIG-8

DERATING CURVE

MEAN-WELL-NTS-400P-Series-True-Sine-Wave-DC-AC-Power-Inverter-
FIG-9

Remote ON-OFF Control

Remote ON-OFF (CN301 PIN1,2)|

AC Output Status

---|---
Open| power inverter ON
Short| power inverter OFF

AC output voltage、Frequency、Power saving mode selectable by DIP SW

Output Voltage and Frequency Setting Factory settings are either 110Vac/60Hz or 230Vac/50Hz, users are able to adjust the voltage and frequency, through the DIP switch of position 1,2,3,4.

AC Output Voltage、 Frequency、Power saving mode selectable by DIP SW

SW1 SW2| SW3| SW4
OFF OFF : 100Vac or 200Vac| ON : 50Hz| ON : Saving mode
OFF ON : 110Vac or 220Vac
ON      OFF : 115Vac or 230Vac| OFF: 60Hz| OFF: Non-Saving mode
ON      ON : 120Vac or 240Vac

Support Tx/R for monitoring power inverter status

  • Users can monitor the status of the power inverter through T×/Rx, and can modify the input and output parameters set internally.

LED STATUS

Normal work

MEAN-WELL-NTS-400P-Series-True-Sine-Wave-DC-AC-Power-Inverter-
FIG-12

Abnormal status

MEAN-WELL-NTS-400P-Series-True-Sine-Wave-DC-AC-Power-Inverter-
FIG-13

MECHANICAL SPECIFICATION

MEAN-WELL-NTS-400P-Series-True-Sine-Wave-DC-AC-Power-Inverter-
FIG-14

  • DC Input Connector(TB1): Anderson 1327 &1327G6 or equivalent
Pin No. Description Mating Housing Terminal
Red DC Input +V 1327 or equivalent 261G2-LPBK

or equivalent

Black| DC Input -V| 1327G6 or equivalent

  • AC Output Connector(CN500): JST B6P-VH or equivalent
Pin No. Assignment Mating Housing Terminal
1 FG

JST VHR

or equivalent

|

JST SVH-21T-P1.1

or equivalent

2,3| NC
4| Output AC/N
5| NC
6| Output AC/L

  • Remote ON-OFF Control Connector(CN301): JST S2B-XH-A or equivalent
Pin No. Description Mating Housing Terminal
1 Pin 1,2 Open: Inverter Normal work JST XHP

or equivalent

| JST SXH-001T

or equivalent

2| Pin 1,2 Short: Inverter Remote off

  • Communicating Function Connector(CN50): CHYAO SHIUN JS-100R-03 or equivalent
Pin No. Description Mating Housing Terminal
1 Signal GND

CHYAO SHIUNN JS-2001

or equivalent

| CHYAO SHIUNN JS-2001-TX

or equivalent

2| UART-RX
3| UART-TX

  • FAN Connector(CN100): JST B3B-XH-A or equivalent
  • Suggested Fan model: CCHV CHT4012BH-W20D 4020B
Pin No. Description Mating Housing Terminal
1 Fan supply +V

12V/0.4A max.

|

JST XHP

or equivalent

|

JST SXH-001T

or equivalent

2| Fan supply -V
3| PWM signal for Fan speed control

TYPICAL APPLICATION

MEAN-WELL-NTS-400P-Series-True-Sine-Wave-DC-AC-Power-Inverter-
FIG-15MEAN-WELL-NTS-400P-
Series-True-Sine-Wave-DC-AC-Power-Inverter-FIG-16

INSTALLATION MANUAL

Please refer to : http://www.meanwell.com/manual.html.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals