MEAN WELL LRS-100N2 Single Output High Peak Power Supply Owner’s Manual
- June 13, 2024
- MEAN WELL
Table of Contents
MEAN WELL LRS-100N2 Single Output High Peak Power Supply

Features
- Universal AC input/ Full range
- Withstand 300VAC surge input for 5 second
- Up to 200% peak power capability
- Protections: Short circuit/ Overload/ Over voltage
- Cooling by free air convection
- Miniature size and 1 U low profile
- Compliance to IEC/BS EN/EN61558-1 and 62368-1
- Operating altitude up to 4000 meters
- Withstand 5G vibration test
- LED indicator for power on
- No load power consumption<0.5W
- Over voltage category III(OVC III)
- High operating temperature up to 70°C
- High efficiency, long life and high reliability
- 3 years warranty

Applications
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Electronic instruments, equipment’s or apparatus
- For inductive and capacitive load
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
LRS-1 00N2 series is a 100W single-output enclosed type power supply with 30mm
of low profile design.
Adopting the full range 85~264VAC input, the entire series provides an output
voltage line of 12V, 24V, 36V and 48V. In addition to the high efficiency up
to 90.5%, the design of metallic mesh case enhances the heat dissipation of
LRS-1 00N2 that the whole series operates from -30°C through 70°C under air
convection without a fan. Delivering an extremely low no load power
consumption (less than 0.5W), it allows the end system to easily meet the
worldwide energy requirement. LRS-1 00N2 has the complete protection functions
and 5G anti-vibration capability; it is complied with the international safety
regulations such as TUV BS EN/EN62368-1, BS EN/EN61558-1/-2-16, UL62368-1 and
GB4943. LRS-1 00N2 series serves as a high price-to-performance power supply
solution for various industrial applications. Moreover, LRS-100N2 can provide
200% short-duration peak power for motor applications and electromechanical
loads requiring much higher power during start-up.
Model Encoding

SPECIFICATION
MODEL|  LRS-100N2-12|  LRS-100N2-24|  LRS-100N2-36|  LRS-
100N2-48
---|---|---|---|---
OUTPUT|  DC VOLTAGE|  12V| 24V| 36V| 48V
RATED CURRENT|  8.5A| 4.2A| 2.8A| 2.1A
CURRENT RANGE|  0 – 8.5A| 0-4.2A| 0-2.8A| 0 – 2.1A
RATED POWER|  102W| 100.8W| 100.8W| 100.8W
RIPPLE & NOISE (max.) Note.2|  120mVp-p| 150mVp-p| 200mVp-p| 200mVp-p
VOLTAGE ADJ. RANGE|  10.2-13.8V| 21.6 – 28.8V| 32.4 – 39.6V| 43.2 – 52.8V
VOLTAGE TOLERANCE|  ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION|  ±0.5%| ±0.5%| ± 0.5%| ±0.5%
LOAD REGULATION|  ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME|  500ms, 30ms/230VAC         500ms,30ms/115VAC at full
load
HOLD UP TIME (Typ.)|  55ms/230VAC      10ms/115VAC at full load
INPUT|  VOLTAGE RANGE|  85-264VAC         120 – 373VDC (Withstand
300VAC surge for 5sec. Without damage)
FREQUENCY RANGE|  47 – 63Hz
EFFICIENCY (Typ.)|  88%| 90%| 90%| 90.5%
AC CURRENT (Typ.)|  2.1A/115VAC         1.2A/230VAC
INRUSH CURRENT (Typ.)|  COLD START 55A/230VAC
LEAKAGE CURRENT|  <0.75mA/ 240VAC
PROTECTION|  OVER LOAD|  Output power >105% rated for more than 5
seconds then shut down o/p voltage, re-power on to recover
Ouput power >200% rated, hiccup mode, recovers automatically after fault
condition is removed
OVER VOLTAGE|  13.8-16.2V| 28.8 – 33.6V| 41.4-48.6V| 55.2 – 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT|  WORKING TEMP.|  -30 – +70°C (Refer to “Derating Curve”)
WORKING HUMIDITY|  20 – 90% RH non-condensing
STORAGE TEMP., HUMIDITY|  -40 – +85°C, 10 – 95% RH non-condensing
TEMP. COEFFICIENT|  ± 0.03%/°C (0 – 50°C)
VIBRATION|  10 – 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
OVER VOLTAGE CATEGORY|  III; Compliance to BS EN/EN61558, BS EN/EN50178,
BS EN/EN60664-1, BS EN/EN624 77-1; altitude up to 4000 meters
SAFETY & EMC (Note 8)|  SAFETY STANDARDS|  UL 62368-1, TUV BS
EN/EN62368-1 , BS EN/EN61558-1 /-2-16,CQC GB4943.1,BSMI CNS14336-1, EAC TP TC
004,S/NZS62368.1(by CB), BIS IS13252(Part1 ): 2010/IEC 60950-1: 2005 approved
Designed refer to AS/NZS 61558.1/2.16, AS/NZS 62368.1
WITHSTAND VOLTAGE|  I/P-O/P:4KVAC     I/P-FG:2KVAC     O/P-FG:1.25KVAC
ISOLATION RESISTANCE|  I/P-O/P, I/P-FG, O/P-FG:100M Ohms/ 500VDC I
25°C! 70% RH
EMC EMISSION|  Compliance to BS EN/EN55032 (CISPR32) Class B, BS
EN/EN55014, BS EN/EN61000-3-2 Class A(:580% Load), BS EN/EN61000-3-3, BSMI
CNS13438, EAC TP TC 020
EMC IMMUNITY|  Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS
EN/EN61000-6-2 (BS EN/EN50082-2),BS EN/EN55035,
heavy industry level, EAC TP TC 020
OTHERS|  MTBF|  2802.6K hrs min.     Telcordia SR-332 (Bellcore);
536.6Khrs min .    MIL-HDBK-21 ?F (25°C)
DIMENSION|  1299730mm (LWH)
PACKING|  0.35Kg; 40pcs/15Kg/0.92CUFT
NOTE|
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
- The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”(as available on http://www.meanwell.com)
- RCM is on voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1.
 X Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Block Diagram

Derating Curve

Static Characteristics

Function Manual
Peak Power

Pav : Average output power ( w )
Ppk : Peak output power (w )
Pnpk : Non peak output power – ( w)
Prated : Rated output power ( w )
t : Peak power width ( sec )
T: Period ( sec )


For example (24 model)
V =220VAC, Duty max=10% in
P =P =100W av rated
P =200W pk
t≤5sec  
Mechanical Specification


Terminal Pin No. Assignment
Pin No.
| Assignment| Pin No.|
Assignment
---|---|---|---
1
| AC/L| 4,5| DCOUTPUT-V
2
| AC/N| 6,7|
DCOUTPUT+V
3| FG-½| |
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>