  • Universal AC input/ Full range
  • Withstand 300VAC surge input for 5 second
  • Up to 200% peak power capability
  • Protections: Short circuit/ Overload/ Over voltage
  • Cooling by free air convection
  • Miniature size and 1 U low profile
  • Compliance to IEC/BS EN/EN61558-1 and 62368-1
  • Operating altitude up to 4000 meters
  • Withstand 5G vibration test
  • LED indicator for power on
  • No load power consumption<0.5W
  • Over voltage category III(OVC III)
  • High operating temperature up to 70°C
  • High efficiency, long life and high reliability
  • 3 years warranty

Features

Applications

  • Industrial automation machinery
  • Industrial control system
  • Mechanical and electrical equipment
  • Electronic instruments, equipment’s or apparatus
  • For inductive and capacitive load

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

Description

LRS-1 00N2 series is a 100W single-output enclosed type power supply with 30mm of low profile design.
Adopting the full range 85~264VAC input, the entire series provides an output voltage line of 12V, 24V, 36V and 48V. In addition to the high efficiency up to 90.5%, the design of metallic mesh case enhances the heat dissipation of LRS-1 00N2 that the whole series operates from -30°C through 70°C under air convection without a fan. Delivering an extremely low no load power consumption (less than 0.5W), it allows the end system to easily meet the worldwide energy requirement. LRS-1 00N2 has the complete protection functions and 5G anti-vibration capability; it is complied with the international safety regulations such as TUV BS EN/EN62368-1, BS EN/EN61558-1/-2-16, UL62368-1 and GB4943. LRS-1 00N2 series serves as a high price-to-performance power supply solution for various industrial applications. Moreover, LRS-100N2 can provide 200% short-duration peak power for motor applications and electromechanical loads requiring much higher power during start-up.

Model Encoding

Model Encoding

SPECIFICATION

MODEL| LRS-100N2-12| LRS-100N2-24| LRS-100N2-36| LRS- 100N2-48
---|---|---|---|---
OUTPUT| DC VOLTAGE| 12V| 24V| 36V| 48V
RATED CURRENT| 8.5A| 4.2A| 2.8A| 2.1A
CURRENT RANGE| 0 – 8.5A| 0-4.2A| 0-2.8A| 0 – 2.1A
RATED POWER| 102W| 100.8W| 100.8W| 100.8W
RIPPLE & NOISE (max.) Note.2| 120mVp-p| 150mVp-p| 200mVp-p| 200mVp-p
VOLTAGE ADJ. RANGE| 10.2-13.8V| 21.6 – 28.8V| 32.4 – 39.6V| 43.2 – 52.8V
VOLTAGE TOLERANCE| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ± 0.5%| ±0.5%
LOAD REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 500ms, 30ms/230VAC         500ms,30ms/115VAC at full load
HOLD UP TIME (Typ.)| 55ms/230VAC      10ms/115VAC at full load
INPUT| VOLTAGE RANGE| 85-264VAC         120 – 373VDC (Withstand 300VAC surge for 5sec. Without damage)
FREQUENCY RANGE| 47 – 63Hz
EFFICIENCY (Typ.)| 88%| 90%| 90%| 90.5%
AC CURRENT (Typ.)| 2.1A/115VAC         1.2A/230VAC
INRUSH CURRENT (Typ.)| COLD START 55A/230VAC
LEAKAGE CURRENT| <0.75mA/ 240VAC
PROTECTION| OVER LOAD| Output power >105% rated for more than 5 seconds then shut down o/p voltage, re-power on to recover
Ouput power >200% rated, hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE| 13.8-16.2V| 28.8 – 33.6V| 41.4-48.6V| 55.2 – 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT| WORKING TEMP.| -30 – +70°C (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 – 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 – +85°C, 10 – 95% RH non-condensing
TEMP. COEFFICIENT| ± 0.03%/°C (0 – 50°C)
VIBRATION| 10 – 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
OVER VOLTAGE CATEGORY| III; Compliance to BS EN/EN61558, BS EN/EN50178, BS EN/EN60664-1, BS EN/EN624 77-1; altitude up to 4000 meters
SAFETY & EMC (Note 8)| SAFETY STANDARDS| UL 62368-1, TUV BS EN/EN62368-1 , BS EN/EN61558-1 /-2-16,CQC GB4943.1,BSMI CNS14336-1, EAC TP TC 004,S/NZS62368.1(by CB), BIS IS13252(Part1 ): 2010/IEC 60950-1: 2005 approved

Designed refer to AS/NZS 61558.1/2.16, AS/NZS 62368.1

WITHSTAND VOLTAGE| I/P-O/P:4KVAC     I/P-FG:2KVAC     O/P-FG:1.25KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms/ 500VDC I 25°C! 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN55014, BS EN/EN61000-3-2 Class A(:580% Load), BS EN/EN61000-3-3, BSMI CNS13438, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61000-6-2 (BS EN/EN50082-2),BS EN/EN55035,

heavy industry level, EAC TP TC 020

OTHERS| MTBF| 2802.6K hrs min.     Telcordia SR-332 (Bellcore); 536.6Khrs min .    MIL-HDBK-21 ?F (25°C)
DIMENSION| 1299730mm (LWH)
PACKING| 0.35Kg; 40pcs/15Kg/0.92CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
  4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”(as available on http://www.meanwell.com)
  5. RCM is on voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1.
    X Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Block Diagram

Block Diagram

Derating Curve

Derating Curve

Static Characteristics

Static Characteristics

Function Manual

Peak Power


Pav : Average output power ( w )
Ppk : Peak output power (w )
Pnpk : Non peak output power – ( w)
Prated : Rated output power ( w )
t : Peak power width ( sec )
T: Period ( sec )

Function Manual
Function Manual

For example (24 model)
V =220VAC, Duty max=10% in
P =P =100W av rated
P =200W pk
t≤5sec

Mechanical Specification

Mechanical Specification
Mechanical Specification

Terminal Pin No. Assignment

Pin No.

| Assignment| Pin No.|

Assignment

---|---|---|---

1

| AC/L| 4,5| DCOUTPUT-V

2

| AC/N| 6,7|

DCOUTPUT+V

3| FG-½| |

Installation Manual

Please refer to : http://www.meanwell.com/manual.html

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals